{"title":"Glass Thickness Meters","description":"\u003cp\u003eGlass thickness meters check supported panes and glazing structures using the measuring method specified for the instrument. This collection includes single-side glass and air-gap checks and instruments intended for double or triple glazing. Choose by the number of panes, pane thickness, air-gap range and the surface access available on the installation. Confirm support for tinted, coated or laminated glass on the individual product page before choosing. These optical glass instruments serve a different measuring task from paint coating gauges and ultrasonic wall thickness gauges.\u003c\/p\u003e\u003ch2\u003eCompare glazing measurement options\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable\u003e\n\u003ccaption\u003eCompare glazing measurement options\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eProduct starting point\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to compare\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/glass-air-gap-thickness-meter-ls200\"\u003eLS200 glass and air-gap meter\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCheck the pane and air-gap arrangement supported by the single-side method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/digital-glass-thickness-meter-ls201\"\u003eLS201 digital glass meter\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCompare the supported double or triple glazing structure and display workflow.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","products":[{"product_id":"glass-air-gap-thickness-meter-ls200","title":"Glass Thickness Meter LS200 for Single-Side Pane and Air-Gap Checks","description":"\u003cp\u003eMeasure pane thickness and the air space in insulating glass from one accessible side with the Linshang LS200 glass thickness meter. Laser reflections from the glass surfaces appear on a graduated scale, allowing the operator to read the positions and calculate layer thickness. The compact instrument suits glazing checks where the pane edge is difficult to reach with a ruler or caliper.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/glass-thickness-meter-ls200-scale-reading.jpg?v=1793767482\" alt=\"LS200 glass and air-space scales with reflected beam positions\" width=\"990\" height=\"639\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS200 glass and air-space scales with reflected beam positions\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eSeparate glass and air-space scales\u003c\/h3\u003e\u003cp\u003eThe instrument has a glass-thickness scale up to 70mm and an air-space scale up to 34mm. Read the reflected beam positions on the appropriate scale and use the spacing between them to determine the required layer thickness. A double-glazed unit produces four reflections, while triple glazing produces six.\u003c\/p\u003e\u003cp\u003eThe LS200 uses a manual scale-reading workflow. Hold the meter flat against the glass and identify the reflections before recording a result. Separate scales keep the pane reading and the insulating cavity reading identifiable during a check.\u003c\/p\u003e\u003ch3\u003eMeter specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement principle\u003c\/th\u003e\n\u003ctd\u003eLaser reflection from glass surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReadout\u003c\/th\u003e\n\u003ctd\u003eGraduated glass-thickness and air-space scales\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGlass-thickness scale\u003c\/th\u003e\n\u003ctd\u003eUp to 70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir-space scale\u003c\/th\u003e\n\u003ctd\u003eUp to 34mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum measurement area\u003c\/th\u003e\n\u003ctd\u003e10 x 100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eCR2032, 3V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e160 x 55 x 25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/glass-thickness-meter-ls200-multiple-panes.jpg?v=1793767491\" alt=\"LS200 reflected beam patterns for single, double and triple glazing\" width=\"990\" height=\"761\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS200 reflected beam patterns for single, double and triple glazing\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003ePositioning and laser precautions\u003c\/h3\u003e\u003cp\u003eKeep the glass surface and instrument scale clean. The meter must rest flat against the pane, because tilting it changes the reflected beam positions. Make sure the sample covers the measurement area, and avoid placing anything between the instrument and the glass.\u003c\/p\u003e\u003cp\u003eThe laser exits from the back of the meter. Keep the beam away from eyes and check the other side of the window before testing. Read the scale from a suitable viewing angle in bright surroundings while maintaining flat contact with the glass. Protect the scale from alcohol and other organic solvents during cleaning.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68119902715947,"sku":"THK-G4S8-01","price":450.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/glass-thickness-meter-ls200-front-insulating-unit-square-main-1200-v3.jpg?v=1793780674"},{"product_id":"digital-glass-thickness-meter-ls201","title":"Digital Glass Thickness Meter LS201 for Double and Triple Glazing","description":"\u003cp\u003eThe Linshang LS201 digital glass thickness meter displays glass-layer and air-gap readings from one side of a glazing unit. Laser reflection and CCD detection support checks on double glazing, triple glazing and laminated assemblies. The digital readout helps document pane and cavity dimensions when access to the glass edge is limited.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/digital-glass-thickness-meter-ls201-layer-identification.jpg?v=1793767557\" alt=\"LS201 digital display identifying glass layers and air spaces\" width=\"990\" height=\"688\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS201 digital display identifying glass layers and air spaces\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRead the glazing structure\u003c\/h3\u003e\u003cp\u003eThe meter covers glass thickness up to 70mm and air-space thickness up to 45mm. For a triple-glazed unit, its display can identify three glass layers and two intervening air spaces. The stated measurement accuracy is ±(0.1mm + 1%H), where H is the reference thickness.\u003c\/p\u003e\u003cp\u003eFor laminated glass, the laminate interlayer cannot be measured independently. Its thickness is included in an adjacent glass value, and the instrument may show a combined glass result when it cannot resolve the internal interface. Account for this behavior when interpreting a laminated assembly.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/digital-glass-thickness-meter-ls201-manual-mode.jpg?v=1793767573\" alt=\"LS201 manual mode for setting layer types and estimated thickness\" width=\"990\" height=\"754\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS201 manual mode for setting layer types and estimated thickness\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eAutomatic and manual measurement\u003c\/h3\u003e\u003cp\u003eAutomatic mode can present several possible layer results for review. Select the result that matches the sample structure. Manual mode lets the operator enter layer types and estimated thicknesses when the automatic results do not fit the glazing. Keep the expected glass arrangement available when checking a complex unit.\u003c\/p\u003e\u003ch3\u003eDetails and specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement principle\u003c\/th\u003e\n\u003ctd\u003eLaser reflection with CCD detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGlass \/ air-space range\u003c\/th\u003e\n\u003ctd\u003eUp to 70mm \/ up to 45mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement accuracy\u003c\/th\u003e\n\u003ctd\u003e±(0.1mm + 1%H), H is reference thickness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModes\u003c\/th\u003e\n\u003ctd\u003eAutomatic and manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e240 x 160 dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum measurement area\u003c\/th\u003e\n\u003ctd\u003e5 x 50mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFour alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e130 x 72 x 33mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e330g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003ePreparing an installed-window check\u003c\/h3\u003e\u003cp\u003ePlace the back of the instrument closely against a clean glass surface. Strong direct sunlight, dirt, scratches or a highly reflective low-E layer can prevent layer identification. Where appropriate, change the accessible measurement surface and review the result against the known assembly.\u003c\/p\u003e\u003cp\u003eKeep the detector clean and avoid looking into the rear laser outlet. Check that people on the other side of the glass are clear of the beam before taking a reading. English and Chinese interface settings are available.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68119903731755,"sku":"THK-L9T5-01","price":841.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/digital-glass-thickness-meter-ls201-front-display-square-main-1200-v3.jpg?v=1793780684"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/collections\/digital-glass-thickness-meter-ls201-front-display-square-main-1200-v3.jpg?v=1793791248","url":"https:\/\/mcooh.com\/collections\/glass-thickness-meters.oembed","provider":"Mcooh","version":"1.0","type":"link"}