{"title":"New Arrivals","description":"\u003cp\u003eDiscover the latest arrivals in test \u0026amp; measurement instruments from Mcooh. Explore newly added digital meters and professional testing tools for industrial, lab, and field use—designed to help you measure with confidence and work more efficiently. Browse what’s new and find the right instrument for your next job.\u003c\/p\u003e","products":[{"product_id":"portable-h2s-gas-detector-1200h-s-h2s","title":"MH-1200H-S-H2S Detector — Diffusion, 50\/100\/200 ppm","description":"\u003cp\u003eThe MH-1200H-S-H2S is the diffusion hydrogen-sulfide model with separate 0-50, 0-100 and 0-200 ppm configurations. It is a single-gas choice for a named H2S measurement requirement. If other channels are required, compare a model that lists those gases explicitly.\u003c\/p\u003e\n\u003ch2\u003eChoose the Configuration for Your Measurement\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas and options:\u003c\/strong\u003e Hydrogen sulfide, with three current range\/SKU pairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSampling:\u003c\/strong\u003e Diffusion sampling is stated in the product description.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelection boundary:\u003c\/strong\u003e A single H2S instrument does not acquire O2, CO or combustible-gas channels from the application name.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrder Options\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCurrent options for this product\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSelect an option\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/portable-h2s-gas-detector-1200h-s-h2s?variant=67589429002283\"\u003e0-50 ppm\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGAS-H7Q2-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/portable-h2s-gas-detector-1200h-s-h2s?variant=67589429035051\"\u003e0-100 ppm\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGAS-H7Q2-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/portable-h2s-gas-detector-1200h-s-h2s?variant=67589429067819\"\u003e0-200 ppm\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGAS-H7Q2-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOpen an option to review its current price and purchase controls. Each option is a separate order configuration; use the selected product and SKU when confirming the supplied package.\u003c\/p\u003e\n\u003ch2\u003eProduct Details and Specifications\u003c\/h2\u003e\n\u003cp\u003eThe MH-1200H-S-H2S is a portable hydrogen sulfide detector for H2S checks during facility and field inspections. An electrochemical sensor measures gas in the air around the instrument through diffusion sampling. The detector has a rear clip and protective cover for carrying during a measurement round. Select the required H2S range when ordering; each range is a separate product variant.\u003c\/p\u003e\n\u003ch3\u003eH2S Range Options\u003c\/h3\u003e\n\u003cp\u003eChoose from 0-50 ppm, 0-100 ppm, or 0-200 ppm according to the concentration span required for your work. The three ranges are separate order configurations. The standard configuration samples by diffusion. An external sampling pump is an optional setup for applications that need a different sampling arrangement; confirm the pump setup before ordering.\u003c\/p\u003e\n\u003ch3\u003eReadings, Alarms, and Records\u003c\/h3\u003e\n\u003cp\u003eThe monochrome dot-matrix LCD shows the gas reading and concentration unit. The display supports ppm and mg\/m³ units, and its backlight can be set to switch on automatically during an alarm. Audible, visual, and vibration alarms give three ways to notice an alert. Alarm points can be configured, and up to 100 alarm records can be reviewed on the detector. Zero and self-calibration functions are available on the instrument.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eMH-1200H-S-H2S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured gas\u003c\/th\u003e\n\u003ctd\u003eHydrogen sulfide (H2S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling method\u003c\/th\u003e\n\u003ctd\u003eDiffusion; external pump setup optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange configurations\u003c\/th\u003e\n\u003ctd\u003e0-50 ppm; 0-100 ppm; 0-200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 monochrome dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConcentration units\u003c\/th\u003e\n\u003ctd\u003eppm and mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm modes\u003c\/th\u003e\n\u003ctd\u003eSound, light, and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAudible alarm\u003c\/th\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm history\u003c\/th\u003e\n\u003ctd\u003e100 records, viewable on the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight\u003c\/th\u003e\n\u003ctd\u003eAdjustable timing; automatic activation during an alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium-polymer battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e131 x 83 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate unit weight\u003c\/th\u003e\n\u003ctd\u003e240 g with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBefore Use\u003c\/h3\u003e\n\u003cp\u003eWith diffusion sampling, the surrounding air must reach the detector's sensor openings. Follow the supplied instructions and your site's procedures for calibration, alarm settings, and gas-monitoring checks. Product photos show the shared housing; the demonstration screen labels may differ from the ordered H2S configuration.\u003c\/p\u003e\n\u003ch2\u003eCompare the Relevant Alternative\u003c\/h2\u003e\n\u003cp\u003eBH-4S O2\/EX\/H2S\/CO provides a different, four-channel configuration. This MH-1200H-S product offers a choice of H2S spans instead. Compare gas coverage first, then sampling, range and package requirements.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/products\/multi-gas-detector-o2-ex-h2s-co-bh-4s\"\u003eView the comparison model and its options\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eQuestions Before Ordering\u003c\/h2\u003e\n\u003ch3\u003eShould I select H2S-only or multi-gas?\u003c\/h3\u003e\n\u003cp\u003eWrite down all required gas channels for the task. Select this product for its H2S configuration; compare an explicitly multi-gas model when more channels are required.\u003c\/p\u003e\n\u003ch3\u003eAre the three ranges measured simultaneously?\u003c\/h3\u003e\n\u003cp\u003eThey are separate variants with separate SKUs. The current selector does not establish a three-range instrument.\u003c\/p\u003e\n\u003ch2\u003eSelection and Use Guides\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/gas-detector\/single-gas-vs-multi-gas-detector\"\u003eSingle-gas vs multi-gas selection\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/gas-detector\/gas-detector-bump-test-vs-calibration\"\u003eBump testing and calibration: what each does\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/gas-detector\"\u003eBrowse gas detectors by gas and measurement task\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSelection note:\u003c\/strong\u003e Follow the supplied instrument instructions and the applicable site procedure. This product comparison does not replace a site-specific risk assessment.\u003c\/p\u003e\n","brand":"Mcooh","offers":[{"title":"0-50 ppm","offer_id":67589429002283,"sku":"GAS-H7Q2-01","price":268.12,"currency_code":"USD","in_stock":true},{"title":"0-100 ppm","offer_id":67589429035051,"sku":"GAS-H7Q2-02","price":277.91,"currency_code":"USD","in_stock":true},{"title":"0-200 ppm","offer_id":67589429067819,"sku":"GAS-H7Q2-03","price":277.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/portable-h2s-gas-detector-front.jpg?v=1790733035"},{"product_id":"portable-chlorine-gas-detector-mh-1200h-s-cl2","title":"MH-1200H-S-CL2 Chlorine Gas Detector — Four ppm Options","description":"\u003cp\u003eThe MH-1200H-S-CL2 measures chlorine gas using diffusion sampling. Four current order variants provide 0-10, 0-20, 0-50 and 0-100 ppm spans. Match the Cl2 gas measurement requirement and selected range; this is a different task from measuring chlorine in water.\u003c\/p\u003e\n\u003ch2\u003eChoose the Configuration for Your Measurement\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e Chlorine gas (Cl2), not dissolved-chlorine water measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange menu:\u003c\/strong\u003e Four separate ppm variants; the selected SKU identifies the supplied span.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSampling:\u003c\/strong\u003e Diffusion is the stated method. Confirm an external-pump package separately if the procedure requires it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrder Options\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCurrent options for this product\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSelect an option\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/portable-chlorine-gas-detector-mh-1200h-s-cl2?variant=67594439393323\"\u003e0-10 ppm\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGAS-Q9C4-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/portable-chlorine-gas-detector-mh-1200h-s-cl2?variant=67594439426091\"\u003e0-20 ppm\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGAS-Q9C4-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/portable-chlorine-gas-detector-mh-1200h-s-cl2?variant=67594439458859\"\u003e0-50 ppm\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGAS-Q9C4-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/portable-chlorine-gas-detector-mh-1200h-s-cl2?variant=67594439491627\"\u003e0-100 ppm\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGAS-Q9C4-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOpen an option to review its current price and purchase controls. Each option is a separate order configuration; use the selected product and SKU when confirming the supplied package.\u003c\/p\u003e\n\u003ch2\u003eProduct Details and Specifications\u003c\/h2\u003e\n\u003cp\u003eThe MH-1200H-S-CL2 is a portable chlorine (Cl2) gas detector for site checks that call for a concentration reading at the instrument. Its electrochemical sensor measures surrounding air by diffusion, and the rear clip and protective cover support carrying the detector during inspection rounds. Choose the required CL2 range when ordering; each range is a separate instrument configuration.\u003c\/p\u003e\u003ch3\u003eChoose a Chlorine Range\u003c\/h3\u003e\u003cp\u003eThe four available measurement spans are 0-10, 0-20, 0-50, and 0-100 ppm. Select the range that matches your monitoring procedure and expected concentration span. The standard instrument uses diffusion sampling. An external sampling pump is an optional setup for tasks that require a different sampling arrangement; confirm that configuration before ordering.\u003c\/p\u003e\u003ch3\u003eDisplay and Alarm Review\u003c\/h3\u003e\u003cp\u003eThe monochrome dot-matrix LCD displays the concentration and supports ppm and mg\/m³ units. Backlight timing can be adjusted, and the light can activate automatically during an alarm. Audible, visual, and vibration alerts provide three ways to notice an alarm; the audible alarm is rated at 85 dB. Alarm thresholds are configurable, and the instrument can retain 100 alarm records for review on its display. Zero and self-calibration functions are available.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eMH-1200H-S-CL2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured gas\u003c\/th\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling method\u003c\/th\u003e\n\u003ctd\u003eDiffusion; external pump setup optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange configurations\u003c\/th\u003e\n\u003ctd\u003e0-10 ppm; 0-20 ppm; 0-50 ppm; 0-100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 monochrome dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConcentration units\u003c\/th\u003e\n\u003ctd\u003eppm and mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm modes\u003c\/th\u003e\n\u003ctd\u003eSound, light, and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAudible alarm\u003c\/th\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm history\u003c\/th\u003e\n\u003ctd\u003e100 records, viewable on the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight\u003c\/th\u003e\n\u003ctd\u003eAdjustable timing; automatic activation during an alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium-polymer battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e131 x 83 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate unit weight\u003c\/th\u003e\n\u003ctd\u003e240 g with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eUse and Configuration Notes\u003c\/h3\u003e\u003cp\u003eFor diffusion sampling, surrounding air must reach the sensor openings. Follow the supplied instructions and your site's procedures for calibration, alarm settings, and gas-monitoring checks. The product photographs show the shared housing used across this model family; gas names on the demonstration screen may differ from the ordered CL2 configuration.\u003c\/p\u003e\n\u003ch2\u003eCompare the Relevant Alternative\u003c\/h2\u003e\n\u003cp\u003eThe pump single-gas family includes a Chlorine (Cl2) sensor option and explicitly describes an internal micro pump. This dedicated MH-1200H-S page offers four Cl2 range choices. Do not transfer those four ranges to the pump family's single Cl2 option.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/products\/portable-pump-single-gas-detector\"\u003eView the comparison model and its options\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eQuestions Before Ordering\u003c\/h2\u003e\n\u003ch3\u003eIs this a chlorine meter for pool or process water?\u003c\/h3\u003e\n\u003cp\u003eNo water-measurement capability is established here. The product is identified as a Cl2 gas detector.\u003c\/p\u003e\n\u003ch3\u003eDoes the pump single-gas alternative provide these same four ranges?\u003c\/h3\u003e\n\u003cp\u003eThe separate pump product has its own Cl2 option and specification table. Compare its actual range instead of inheriting this page's range menu.\u003c\/p\u003e\n\u003ch2\u003eSelection and Use Guides\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/gas-detector\/pumped-vs-diffusion-gas-detector\"\u003ePumped vs diffusion gas detectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/gas-detector\/gas-detector-cross-sensitivity\"\u003eGas sensor cross-sensitivity\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/gas-detector\"\u003eBrowse gas detectors by gas and measurement task\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSelection note:\u003c\/strong\u003e Follow the supplied instrument instructions and the applicable site procedure. This product comparison does not replace a site-specific risk assessment.\u003c\/p\u003e\n","brand":"Mcooh","offers":[{"title":"0-10 ppm","offer_id":67594439393323,"sku":"GAS-Q9C4-01","price":587.47,"currency_code":"USD","in_stock":true},{"title":"0-20 ppm","offer_id":67594439426091,"sku":"GAS-Q9C4-02","price":587.47,"currency_code":"USD","in_stock":true},{"title":"0-50 ppm","offer_id":67594439458859,"sku":"GAS-Q9C4-03","price":597.94,"currency_code":"USD","in_stock":true},{"title":"0-100 ppm","offer_id":67594439491627,"sku":"GAS-Q9C4-04","price":597.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/portable-chlorine-gas-detector-front.jpg?v=1790746848"},{"product_id":"portable-nitric-oxide-gas-detector-mh-1200h-s-no","title":"Nitric Oxide Gas Detector - MH-1200H-S-NO","description":"\u003cp\u003eMonitor nitric oxide (NO) at the point of inspection with the portable MH-1200H-S-NO gas detector. The instrument uses an electrochemical sensor and diffusion sampling to measure surrounding air. Its rear clip and protective case make it practical to carry during inspection rounds. Choose one of four NO measurement ranges to match the concentration span required by your monitoring procedure.\u003c\/p\u003e\u003ch3\u003eChoose the NO Measurement Range\u003c\/h3\u003e\u003cp\u003eOrder the 0-20, 0-50, 0-100 or 0-250 ppm configuration. Each range is a separate instrument variant. The standard sampling method is diffusion, so air at the instrument reaches the sensor opening without a built-in pump. An external sampling pump is an optional configuration when the application requires a different sampling arrangement; confirm the intended setup before ordering.\u003c\/p\u003e\u003ch3\u003eReadings, Alerts and Review\u003c\/h3\u003e\u003cp\u003eThe 128 x 64 monochrome LCD presents gas readings in ppm or mg\/m³. Backlight timing is adjustable, and the backlight can switch on during an alarm. Sound, light and vibration alerts provide multiple alarm cues; the sound alarm is rated at 85 dB. Alarm points can be adjusted for the monitoring procedure, while 100 alarm records can be reviewed on the instrument. Zero and self-calibration functions support routine instrument setup.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCustomer-facing model\u003c\/th\u003e\n\u003ctd\u003eMH-1200H-S-NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured gas\u003c\/th\u003e\n\u003ctd\u003eNitric oxide (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling method\u003c\/th\u003e\n\u003ctd\u003eDiffusion; external sampling pump optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable ranges\u003c\/th\u003e\n\u003ctd\u003e0-20, 0-50, 0-100 and 0-250 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 monochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay units\u003c\/th\u003e\n\u003ctd\u003eppm and mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm modes\u003c\/th\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSound alarm\u003c\/th\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm records\u003c\/th\u003e\n\u003ctd\u003e100, reviewable on the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight\u003c\/th\u003e\n\u003ctd\u003eAdjustable timing; activates during alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e131 x 83 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate instrument weight\u003c\/th\u003e\n\u003ctd\u003e240 g with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSelection and Use Notes\u003c\/h3\u003e\u003cp\u003eSelect the range to suit the expected concentration and your site's alarm and calibration procedure. The detector measures NO, not NO2 or combined NOx. During diffusion use, keep the sensor opening exposed to the air being checked and follow the supplied operating instructions. Product photographs show the shared housing in this series; gas labels on a demonstration screen may differ from the ordered NO configuration.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-20 ppm","offer_id":67594753605675,"sku":"GAS-N6R2-01","price":603.73,"currency_code":"USD","in_stock":true},{"title":"0-50 ppm","offer_id":67594754621483,"sku":"GAS-N6R2-02","price":603.73,"currency_code":"USD","in_stock":true},{"title":"0-100 ppm","offer_id":67594754654251,"sku":"GAS-N6R2-03","price":605.4,"currency_code":"USD","in_stock":true},{"title":"0-250 ppm","offer_id":67594754687019,"sku":"GAS-N6R2-04","price":615.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/portable-nitric-oxide-gas-detector-front.jpg?v=1790751172"},{"product_id":"portable-nitrogen-dioxide-gas-detector-mh-1200h-s-no2","title":"Nitrogen Dioxide (NO2) Detector - 0-20\/50\/100 ppm","description":"\u003cp\u003eThe portable MH-1200H-S-NO2 measures nitrogen dioxide (NO2) in surrounding air during inspection rounds. Its electrochemical sensor uses diffusion sampling, while a rear clip and protective cover help keep the instrument accessible between readings. Select the NO2 measurement span that fits the concentration range required for your procedure.\u003c\/p\u003e\u003ch3\u003eRange and Sampling Choices\u003c\/h3\u003e\u003cp\u003eThe available configurations cover 0-20, 0-50 and 0-100 ppm. Each is a separate range option for the same instrument model. In its standard diffusion setup, ambient air reaches the sensor opening directly.\u003c\/p\u003e\u003ch3\u003eReadings and Alarms\u003c\/h3\u003e\u003cp\u003eA 128 x 64 monochrome LCD shows the gas reading and supports ppm and mg\/m³ display units. Backlight timing is adjustable, with automatic illumination during an alarm. Sound, light and vibration alerts draw attention to an alarm condition, and the sound alarm is rated at 85 dB. Set points can be configured for the monitoring procedure. The instrument retains 100 alarm records that can be reviewed on its display, and zero and self-calibration functions are available for routine setup.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eMH-1200H-S-NO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured gas\u003c\/th\u003e\n\u003ctd\u003eNitrogen dioxide (NO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling method\u003c\/th\u003e\n\u003ctd\u003eDiffusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange options\u003c\/th\u003e\n\u003ctd\u003e0-20, 0-50 and 0-100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 monochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay units\u003c\/th\u003e\n\u003ctd\u003eppm and mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm modes\u003c\/th\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAudible alarm\u003c\/th\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm history\u003c\/th\u003e\n\u003ctd\u003e100 records viewable on the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight\u003c\/th\u003e\n\u003ctd\u003eAdjustable timing and automatic alarm activation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e131 x 83 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate unit weight\u003c\/th\u003e\n\u003ctd\u003e240 g with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eConfiguration Notes\u003c\/h3\u003e\u003cp\u003eThis configuration measures NO2 specifically; an NO detector or combined NOx detector serves a different measurement request. Choose range and alarm settings according to the intended monitoring procedure, and use the supplied instructions for calibration and checking. For diffusion measurement, leave the sensor inlet exposed to the air being monitored. The product photos show the common housing of this series, and their demonstration screen may show other gases.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-20 ppm","offer_id":67597147832363,"sku":"GAS-D7K3-01","price":590.96,"currency_code":"USD","in_stock":true},{"title":"0-50 ppm","offer_id":67597147930667,"sku":"GAS-D7K3-02","price":590.96,"currency_code":"USD","in_stock":true},{"title":"0-100 ppm","offer_id":67597147963435,"sku":"GAS-D7K3-03","price":603.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/portable-nitrogen-dioxide-detector-front.jpg?v=1790755750"},{"product_id":"portable-sulfur-dioxide-gas-detector-mh-1200h-s-so2","title":"Portable SO2 Gas Detector - Diffusion Sampling, 0-20\/50\/100 ppm","description":"\u003cp\u003eThis portable sulfur dioxide gas detector measures SO2 in surrounding air with an electrochemical sensor. The MH-1200H-S-SO2 uses diffusion sampling and comes in three measurement spans: 0-20, 0-50 and 0-100 ppm. Its rear clip keeps the instrument accessible during inspection rounds, while the protective cover surrounds the housing.\u003c\/p\u003e\u003ch3\u003eSO2 Readings and Range Selection\u003c\/h3\u003e\u003cp\u003eChoose the measurement span required for your SO2 monitoring procedure. Each range is a separate configuration of the same instrument. The 128 x 64 monochrome LCD displays gas information and concentration, with ppm and mg\/m³ units available. Backlight timing can be adjusted, and the display illuminates automatically during an alarm.\u003c\/p\u003e\u003ch3\u003eAlarm Indication and On-Device Records\u003c\/h3\u003e\u003cp\u003eSound, light and vibration provide three forms of alarm indication. The audible alarm is rated at 85 dB, and alarm set points can be configured for the monitoring procedure. The detector retains 100 alarm records for review on its screen, allowing the operator to look back at recorded alarm events without connecting to a computer. Zero and self-calibration functions, battery status checks and a factory reset function are available through the instrument controls.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eMH-1200H-S-SO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured gas\u003c\/th\u003e\n\u003ctd\u003eSulfur dioxide (SO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling\u003c\/th\u003e\n\u003ctd\u003eDiffusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange options\u003c\/th\u003e\n\u003ctd\u003e0-20, 0-50 and 0-100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 monochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay units\u003c\/th\u003e\n\u003ctd\u003eppm and mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm modes\u003c\/th\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAudible alarm\u003c\/th\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm history\u003c\/th\u003e\n\u003ctd\u003e100 records viewable on the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight\u003c\/th\u003e\n\u003ctd\u003eAdjustable timing; automatic illumination during an alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e131 x 83 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate instrument weight\u003c\/th\u003e\n\u003ctd\u003e240 g including protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eUse and Configuration Notes\u003c\/h3\u003e\u003cp\u003eFollow the instrument instructions and the monitoring procedure for calibration, checks and alarm settings. Diffusion measurement requires exposure of the sensor inlet to the air being checked. The compact housing measures 131 x 83 x 35 mm and weighs approximately 240 g with its protective cover; power is supplied by a rechargeable 2300 mAh battery. Product photos illustrate the shared housing used in this series. Gas labels on the demonstration screen may differ from the selected SO2 configuration.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-20 ppm","offer_id":67597398999083,"sku":"GAS-X7V4-01","price":588.21,"currency_code":"USD","in_stock":true},{"title":"0-50 ppm","offer_id":67597399031851,"sku":"GAS-X7V4-02","price":588.21,"currency_code":"USD","in_stock":true},{"title":"0-100 ppm","offer_id":67597399064619,"sku":"GAS-X7V4-03","price":599.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/portable-sulfur-dioxide-gas-detector-front.jpg?v=1790759485"},{"product_id":"portable-phosphine-gas-detector-mh-1200h-s-ph3","title":"Phosphine (PH3) Gas Detector - 0-5\/20\/50\/100 ppm","description":"\u003cp\u003eCheck phosphine concentration in surrounding air with this portable phosphine gas detector. The MH-1200H-S-PH3 combines an electrochemical PH3 sensor with diffusion sampling, a rear clip and a protective cover. Four range configurations are available: 0-5, 0-20, 0-50 and 0-100 ppm.\u003c\/p\u003e\u003ch3\u003eChoose the PH3 Measurement Span\u003c\/h3\u003e\u003cp\u003eSelect the span required by your monitoring procedure. Each option is a separate range configuration of the instrument, so the range is selected when ordering. The display resolution is 0.1 ppm. Diffusion sampling measures air at the sensor inlet; keep that inlet exposed to the air being checked and follow the instrument instructions for checks and calibration.\u003c\/p\u003e\u003ch3\u003eConcentration Display and Alarm Review\u003c\/h3\u003e\u003cp\u003eA 128 x 64 monochrome LCD shows the gas and its concentration, with ppm and mg\/m³ display units available. Set the backlight timing through the controls; it also illuminates automatically when an alarm occurs. Sound, light and vibration provide alarm indications, with an 85 dB audible alarm and configurable alarm set points. The instrument stores 100 alarm records for review on its screen.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eMH-1200H-S-PH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured gas\u003c\/th\u003e\n\u003ctd\u003ePhosphine (PH3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling\u003c\/th\u003e\n\u003ctd\u003eDiffusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange options\u003c\/th\u003e\n\u003ctd\u003e0-5, 0-20, 0-50 and 0-100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 monochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay units\u003c\/th\u003e\n\u003ctd\u003eppm and mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm modes\u003c\/th\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAudible alarm\u003c\/th\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm settings\u003c\/th\u003e\n\u003ctd\u003eConfigurable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm history\u003c\/th\u003e\n\u003ctd\u003e100 records viewable on the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight\u003c\/th\u003e\n\u003ctd\u003eAdjustable timing; automatic illumination during an alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e131 x 83 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate instrument weight\u003c\/th\u003e\n\u003ctd\u003e240 g including protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eInstrument Controls and Carrying\u003c\/h3\u003e\u003cp\u003eZero calibration, self-calibration, battery status checks and a factory reset function are available through the instrument controls. Use the specified calibration procedure and the alarm settings required for your monitoring task. A rechargeable 2300 mAh lithium-polymer battery powers the detector. Its housing measures 131 x 83 x 35 mm, and the instrument weighs approximately 240 g including its protective cover. The rear clip provides a carrying point during inspection rounds.\u003c\/p\u003e\u003cp\u003eProduct photos illustrate the housing shared across this series. Gas names on the demonstration screen may differ from the selected PH3 configuration.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-5 ppm","offer_id":67789833928747,"sku":"GAS-P8M6-01","price":588.79,"currency_code":"USD","in_stock":true},{"title":"0-20 ppm","offer_id":67789834813483,"sku":"GAS-P8M6-02","price":588.79,"currency_code":"USD","in_stock":true},{"title":"0-50 ppm","offer_id":67789834846251,"sku":"GAS-P8M6-03","price":600.78,"currency_code":"USD","in_stock":true},{"title":"0-100 ppm","offer_id":67789834879019,"sku":"GAS-P8M6-04","price":600.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/phosphine-gas-detector-front.jpg?v=1791445999"},{"product_id":"portable-nitrogen-gas-detector-mh-1200h-s-n2","title":"Diffusion Nitrogen Gas Detector - N2 0-100% Vol","description":"\u003cp\u003eThis diffusion nitrogen gas detector measures N2 concentration in surrounding air over a 0-100% Vol range. The MH-1200H-S-N2 uses an electrochemical sensor and presents concentration information on a 128 x 64 monochrome LCD. A rear clip and protective cover support carrying during inspection rounds.\u003c\/p\u003e\u003ch3\u003eSampling and Measurement Range\u003c\/h3\u003e\u003cp\u003eThe N2 configuration is supplied with one measurement span: 0-100% Vol, covering nitrogen concentration as a percentage by volume. Diffusion sampling checks air at the instrument's sensor inlet. Keep the inlet exposed to the air being checked and follow the instrument instructions for calibration and pre-use checks. When comparing instruments, select the sampling method needed for your procedure: this configuration uses diffusion sampling.\u003c\/p\u003e\u003ch3\u003eDisplay, Alerts and Alarm History\u003c\/h3\u003e\u003cp\u003eSound, light and vibration provide three forms of alarm indication. The LCD provides concentration information, while adjustable backlight timing allows the display illumination to be set through the controls. The backlight also turns on automatically during an alarm. The instrument stores 100 alarm records that can be reviewed on its screen, allowing the operator to look back at alarm events without connecting to a computer. Battery voltage and charge-percentage checks and a factory reset function are available through the instrument controls.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eMH-1200H-S-N2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured gas\u003c\/th\u003e\n\u003ctd\u003eNitrogen (N2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling\u003c\/th\u003e\n\u003ctd\u003eDiffusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003ctd\u003e0-100% Vol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 monochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm modes\u003c\/th\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm history\u003c\/th\u003e\n\u003ctd\u003e100 records viewable on the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight\u003c\/th\u003e\n\u003ctd\u003eAdjustable timing; automatic illumination during an alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing\u003c\/th\u003e\n\u003ctd\u003eABS housing with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCarrying attachment\u003c\/th\u003e\n\u003ctd\u003eRear clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e131 x 83 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate instrument weight\u003c\/th\u003e\n\u003ctd\u003e240 g including protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eHousing and Use Notes\u003c\/h3\u003e\u003cp\u003eA rechargeable 2300 mAh lithium battery powers the detector. The ABS housing measures 131 x 83 x 35 mm, and the instrument weighs approximately 240 g including its protective cover. Its operating temperature range is -20 to 50 Degree C. Use the instrument within the specified operating conditions and follow your monitoring procedure for setup, checks and alarm handling.\u003c\/p\u003e\u003cp\u003eProduct photos illustrate the housing shared across this series. Gas labels on the demonstration screen may differ from the selected N2 configuration.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-100% Vol","offer_id":67790321483819,"sku":"GAS-T8N4-01","price":515.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/nitrogen-gas-detector-front.jpg?v=1791447522"},{"product_id":"portable-combustible-gas-detector-mh-1200h-s-ex","title":"Combustible Gas Detector - 0-100% LEL, Catalytic Sensor Options","description":"\u003cp\u003eThis portable combustible gas detector uses catalytic combustion sensing to measure flammable gas over a 0-100% LEL range. The MH-1200H-S-EX samples surrounding air by diffusion and offers two sensor performance configurations: Standard and High Performance. Both use the same compact housing with a rear clip and protective cover.\u003c\/p\u003e\u003ch3\u003eChoose the Catalytic Sensor Configuration\u003c\/h3\u003e\u003cp\u003eSelect the performance option for the gases and conditions in your monitoring procedure. Standard provides the conventional catalytic configuration and is not recommended for diesel or acetylene environments. High Performance uses a poisoning-resistant catalytic sensor and supports combustible gas monitoring in diesel and acetylene environments. Both options are supplied with the 0-100% LEL measurement range. The performance configuration is selected when ordering.\u003c\/p\u003e\u003ch3\u003eLEL Display and Alarm Handling\u003c\/h3\u003e\u003cp\u003eThe 128 x 64 monochrome LCD shows gas information and concentration. Sound, light and vibration provide alarm indications, with an 85 dB audible alarm and configurable set points. Backlight timing can be adjusted through the controls, and the display illuminates automatically during an alarm. The instrument stores 100 alarm records that can be reviewed on its screen. Zero calibration, self-calibration, battery status checks and a factory reset function are available through the instrument controls.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eMH-1200H-S-EX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured gas\u003c\/th\u003e\n\u003ctd\u003eCombustible \/ flammable gas (Ex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003ctd\u003eCatalytic combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling\u003c\/th\u003e\n\u003ctd\u003eDiffusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003ctd\u003e0-100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance options\u003c\/th\u003e\n\u003ctd\u003eStandard; High Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 monochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm modes\u003c\/th\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAudible alarm\u003c\/th\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm settings\u003c\/th\u003e\n\u003ctd\u003eConfigurable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm history\u003c\/th\u003e\n\u003ctd\u003e100 records viewable on the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight\u003c\/th\u003e\n\u003ctd\u003eAdjustable timing; automatic illumination during an alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e131 x 83 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate instrument weight\u003c\/th\u003e\n\u003ctd\u003e240 g including protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCarrying and Measurement Notes\u003c\/h3\u003e\u003cp\u003eDiffusion sampling measures air at the sensor inlet. Keep the inlet exposed to the air being checked and follow the instrument instructions and monitoring procedure for calibration, pre-use checks and alarm settings. Confirm that the selected sensor configuration and calibration are appropriate for the gas being measured.\u003c\/p\u003e\u003cp\u003eA rechargeable 2300 mAh lithium-polymer battery powers the detector. The housing measures 131 x 83 x 35 mm, and the instrument weighs approximately 240 g including its protective cover. Product photos illustrate the housing shared across this series; gas labels on the demonstration screen may differ from the selected Ex configuration.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"Standard","offer_id":67790553710635,"sku":"GAS-C7K9-01","price":258.46,"currency_code":"USD","in_stock":true},{"title":"High Performance","offer_id":67790554660907,"sku":"GAS-C7K9-02","price":617.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/combustible-gas-detector-front.jpg?v=1791448264"},{"product_id":"portable-methane-gas-detector-mh-1200h-s-ch4","title":"Portable Methane Detector - CH4 0-100% LEL","description":"\u003cp\u003eMeasure methane at the instrument inlet with this portable methane gas detector. The MH-1200H-S-CH4 uses a catalytic combustion sensor and diffusion sampling to display CH4 concentration over a 0-100% LEL range. Choose either the Standard or High Performance sensor configuration when ordering.\u003c\/p\u003e\u003ch3\u003eCH4 Measurement and Sensor Selection\u003c\/h3\u003e\u003cp\u003eBoth performance options use the same 0-100% LEL methane measurement span. Standard is the conventional catalytic configuration; High Performance uses a poisoning-resistant catalytic sensor. The Standard configuration is not recommended for diesel or acetylene environments. Select the sensor option that matches the gases and conditions in your monitoring procedure, and follow the instrument instructions for calibration and pre-use checks.\u003c\/p\u003e\u003cp\u003eThis configuration uses diffusion sampling at the sensor inlet. Keep the inlet exposed to the air being checked. The rear clip provides a carrying point during inspection rounds, and the protective cover surrounds the compact housing.\u003c\/p\u003e\u003ch3\u003eReadings, Alarm Settings and Stored Events\u003c\/h3\u003e\u003cp\u003eThe 128 x 64 monochrome LCD shows gas information and concentration. Adjustable backlight timing lets you set the display illumination through the controls; the backlight also activates automatically during an alarm. Sound, light and vibration provide alarm indications, with an 85 dB audible alarm and configurable set points. The detector stores 100 alarm records for review on its screen.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eMH-1200H-S-CH4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured gas\u003c\/th\u003e\n\u003ctd\u003eMethane (CH4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003ctd\u003eCatalytic combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003ctd\u003e0-100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance options\u003c\/th\u003e\n\u003ctd\u003eStandard; High Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling\u003c\/th\u003e\n\u003ctd\u003eDiffusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 monochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm modes\u003c\/th\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAudible alarm\u003c\/th\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm settings\u003c\/th\u003e\n\u003ctd\u003eConfigurable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm history\u003c\/th\u003e\n\u003ctd\u003e100 records viewable on the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight\u003c\/th\u003e\n\u003ctd\u003eAdjustable timing; automatic illumination during an alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e131 x 83 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate instrument weight\u003c\/th\u003e\n\u003ctd\u003e240 g including protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eControls and Carrying Details\u003c\/h3\u003e\u003cp\u003eZero calibration, self-calibration, battery status checks and a factory reset function are available through the instrument controls. Set up and check the instrument according to its instructions and the requirements of your methane monitoring procedure.\u003c\/p\u003e\u003cp\u003eA rechargeable 2300 mAh lithium-polymer battery powers the detector. The housing measures 131 x 83 x 35 mm, and the instrument weighs approximately 240 g including its protective cover. Product photos show the housing shared across this series; gas labels on the demonstration screen may differ from the selected CH4 configuration.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"Standard","offer_id":67791037038635,"sku":"GAS-M8D5-01","price":256.04,"currency_code":"USD","in_stock":true},{"title":"High Performance","offer_id":67791038349355,"sku":"GAS-M8D5-02","price":654.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/methane-gas-detector-front.jpg?v=1791449376"},{"product_id":"portable-4-gas-monitor-mh-1200h-s4","title":"Portable 4 Gas Monitor - CO, H2S, O2 and LEL","description":"\u003cp\u003eThis portable 4 gas monitor combines carbon monoxide, hydrogen sulfide, oxygen and combustible gas measurement in one instrument. The MH-1200H-S4 uses diffusion sampling, with electrochemical sensors for CO, H2S and O2 and a catalytic combustion sensor for the LEL channel. It provides the four readings through a monochrome LCD and uses sound, light and vibration for alarm indication.\u003c\/p\u003e\u003ch3\u003eFour Gas Channels in One Configuration\u003c\/h3\u003e\u003cp\u003eThe instrument is supplied as one four-channel configuration. Each gas has its own measurement span and concentration unit:\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGas channel\u003c\/th\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003e0-1000 ppm\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen sulfide (H2S)\u003c\/td\u003e\n\u003ctd\u003e0-100 ppm\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen (O2)\u003c\/td\u003e\n\u003ctd\u003e0-30% Vol\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible gas (LEL)\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003c\/td\u003e\n\u003ctd\u003eCatalytic combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eUse these channel ranges when comparing the monitor with the requirements of your monitoring procedure. CO and H2S are measured in ppm, oxygen in percent by volume and combustible gas in percent LEL. Diffusion sampling measures air at the instrument inlet. Keep the inlet exposed to the air being checked and follow the instrument instructions for calibration and pre-use checks.\u003c\/p\u003e\u003ch3\u003eAlarm Settings and Event Review\u003c\/h3\u003e\u003cp\u003eThe audible alarm is rated at 85 dB, with light and vibration providing additional indications. Alarm set points can be configured for the monitoring procedure. The detector stores 100 alarm records that can be reviewed on the instrument. The 128 x 64 monochrome LCD supports English and Chinese interfaces; backlight timing can be adjusted, and the backlight turns on automatically during an alarm.\u003c\/p\u003e\u003ch3\u003eInstrument Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eMH-1200H-S4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas configuration\u003c\/th\u003e\n\u003ctd\u003eCO, H2S, O2 and combustible gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling\u003c\/th\u003e\n\u003ctd\u003eDiffusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 monochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface languages\u003c\/th\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm modes\u003c\/th\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAudible alarm\u003c\/th\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm settings\u003c\/th\u003e\n\u003ctd\u003eConfigurable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm history\u003c\/th\u003e\n\u003ctd\u003e100 records viewable on the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight\u003c\/th\u003e\n\u003ctd\u003eAdjustable timing; automatic illumination during an alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e131 x 83 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate instrument weight\u003c\/th\u003e\n\u003ctd\u003e240 g including protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eControls and Carrying Details\u003c\/h3\u003e\u003cp\u003eZero calibration, self-calibration, battery status checks and a factory reset function are available through the instrument controls. A rechargeable 2300 mAh lithium-polymer battery powers the monitor. The housing measures 131 x 83 x 35 mm, and the instrument weighs approximately 240 g including its protective cover. A rear clip provides a carrying point during inspection rounds.\u003c\/p\u003e\u003cp\u003eFollow the instrument instructions and your monitoring procedure for setup, calibration, checks and alarm handling. Product photos illustrate the housing shared across this series; gas names on the demonstration screen may differ from the selected configuration.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"CO \/ H2S \/ O2 \/ LEL","offer_id":67791637315627,"sku":"GAS-F4P8-01","price":418.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/portable-4-gas-monitor-front.jpg?v=1791450793"},{"product_id":"pump-4-gas-detector-mh2000-m4","title":"4 Gas Detector with Internal Pump - CO, H2S, O2 and LEL","description":"\u003cp\u003eA 4 gas detector with an internal pump brings CO, H2S, oxygen and combustible gas measurement together in the MH2000-M4. The pump draws air into the instrument for measurement, and its suction has ten adjustable levels. This configuration provides all four gas channels in one handheld unit, with concentration readings on a dot-matrix LCD and two-stage sound and light alarms.\u003c\/p\u003e\u003ch3\u003ePumped Sampling and Daily Controls\u003c\/h3\u003e\u003cp\u003eThe sampling pump has a maximum flow of 1 L\/min. The LCD shows the gas type, concentration, measurement unit, time and battery status; English and Chinese interfaces are available. Temperature and pressure compensation are built into the measurement functions.\u003c\/p\u003e\u003cp\u003eSelf-calibration, zero calibration and a factory reset are available through the instrument controls. Alarm set points can be adjusted for the monitoring procedure. Use the instrument instructions for calibration, checks and alarm handling; this monitor is one part of a workplace gas-monitoring procedure.\u003c\/p\u003e\u003ch3\u003eCO, H2S, Oxygen and LEL Channels\u003c\/h3\u003e\u003cp\u003eThree electrochemical channels measure CO, H2S and O2, while the combustible gas channel uses catalytic combustion. This is one complete four-gas configuration:\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGas channel\u003c\/th\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003e0-1000 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen sulfide (H2S)\u003c\/td\u003e\n\u003ctd\u003e0-100 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen (O2)\u003c\/td\u003e\n\u003ctd\u003e0-30% Vol\u003c\/td\u003e\n\u003ctd\u003e0.01% Vol\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible gas (LEL)\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003c\/td\u003e\n\u003ctd\u003e1% LEL\u003c\/td\u003e\n\u003ctd\u003eCatalytic combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eCO and H2S readings use ppm, oxygen uses percent by volume, and combustible gas uses percent LEL. These units describe different measurements. Compare the channel spans with the gases and ranges required for your task when selecting the instrument.\u003c\/p\u003e\u003ch3\u003eInstrument Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-M4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eCO \/ H2S \/ O2 \/ LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump control\u003c\/td\u003e\n\u003ctd\u003e10 adjustable suction levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot-matrix display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed information\u003c\/td\u003e\n\u003ctd\u003eGas type, concentration, unit, time and battery status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm indication\u003c\/td\u003e\n\u003ctd\u003eSound and light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm settings\u003c\/td\u003e\n\u003ctd\u003eTwo stages with adjustable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration controls\u003c\/td\u003e\n\u003ctd\u003eSelf-calibration and zero calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset control\u003c\/td\u003e\n\u003ctd\u003eRestore factory settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eEngineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Items and Selection Notes\u003c\/h3\u003e\u003cp\u003eThe package includes the detector, a charging\/data cable, an instruction manual and an aluminum carrying case. The instrument uses a rechargeable lithium-polymer battery and measures 205 x 75 x 32 mm. Its engineering-plastic housing is rated IP65.\u003c\/p\u003e\u003cp\u003eChoose this model when your procedure calls for a pump to bring a sample into the detector. The four quoted gas channels are fixed for this configuration. Product photographs illustrate the series housing; demonstration screen readings and gas labels may differ from the supplied configuration.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"CO \/ H2S \/ O2 \/ LEL","offer_id":67800281317419,"sku":"GAS-P4N7-01","price":621.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/4-gas-detector-pump-angle.jpg?v=1791531751"},{"product_id":"pump-carbon-monoxide-detector-mh2000-co","title":"Carbon Monoxide Detector with Pump - 3 Range Options","description":"\u003cp\u003eThe MH2000-CO is a pump carbon monoxide detector for portable concentration measurement. Its electrochemical sensor measures CO, while an internal pump brings an air sample into the instrument. Choose a 0-500, 0-1000 or 0-2000 ppm version to match the measurement span required for your task. Each range is a separate supplied configuration.\u003c\/p\u003e\u003ch3\u003eSelect the CO Measurement Range\u003c\/h3\u003e\u003cp\u003eThe three versions share the pumped sampling platform, display and controls. The selected range defines the measurement span of the instrument you order; it is not a menu setting that changes one version into another.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eOrder option\u003c\/th\u003e\n\u003cth\u003eMeasured gas\u003c\/th\u003e\n\u003cth\u003eSampling method\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0-500 ppm\u003c\/td\u003e\n\u003ctd\u003eCarbon monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003eInternal pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0-1000 ppm\u003c\/td\u003e\n\u003ctd\u003eCarbon monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003eInternal pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0-2000 ppm\u003c\/td\u003e\n\u003ctd\u003eCarbon monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003eInternal pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eThe 0-1000 ppm version has a resolution of 1 ppm. The detector measures carbon monoxide, not carbon dioxide. Choose the range using your measurement requirements, alongside the alarm settings and checks specified by your monitoring procedure.\u003c\/p\u003e\u003ch3\u003eSampling, Readings and Alarms\u003c\/h3\u003e\u003cp\u003ePump suction is adjustable in ten levels, with a maximum flow of 1 L\/min. The dot-matrix LCD shows the gas type, concentration, unit, time and battery status. English and Chinese interfaces are available, and concentration units can be switched between ppm and mg\/m3.\u003c\/p\u003e\u003cp\u003eSound, light and vibration provide alarm indication. The audible alarm is rated at 85 dB, and the two-stage alarm set points are adjustable. Temperature and pressure compensation are built into the measurement functions. Instrument controls include a self-check function, zero calibration and a factory reset.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-CO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured gas\u003c\/td\u003e\n\u003ctd\u003eCarbon monoxide (CO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange options\u003c\/td\u003e\n\u003ctd\u003e0-500 ppm, 0-1000 ppm or 0-2000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling\u003c\/td\u003e\n\u003ctd\u003eInternal pump, up to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution, 0-1000 ppm version\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot-matrix display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed information\u003c\/td\u003e\n\u003ctd\u003eGas type, concentration, unit, time and battery status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm modes\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm levels\u003c\/td\u003e\n\u003ctd\u003eTwo stages with adjustable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003eApproximately 4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eEngineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate instrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003ePower and Package Contents\u003c\/h3\u003e\u003cp\u003eA 3.6 V, 2300 mAh rechargeable lithium-polymer battery powers the detector. Charging takes approximately four to six hours. The instrument measures 205 x 75 x 32 mm and weighs about 300 g; its engineering-plastic housing is rated IP65.\u003c\/p\u003e\u003cp\u003eThe package includes the detector, a charging\/data cable, an instruction manual and an aluminum carrying case. Follow the instrument instructions for setup, calibration, checks and alarm handling. Product photographs show the shared housing of this series; demonstration gas labels and screen readings may differ from the selected CO configuration.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-500 ppm","offer_id":67800330731563,"sku":"GAS-C8R4-01","price":512.91,"currency_code":"USD","in_stock":true},{"title":"0-1000 ppm","offer_id":67800330862635,"sku":"GAS-C8R4-02","price":512.95,"currency_code":"USD","in_stock":true},{"title":"0-2000 ppm","offer_id":67800330895403,"sku":"GAS-C8R4-03","price":520.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/carbon-monoxide-detector-pump-angle.jpg?v=1791534119"},{"product_id":"pump-hydrogen-sulfide-detector-mh2000-h2s","title":"H2S Gas Detector - Pump Sampling, 50\/100\/200 ppm","description":"\u003cp\u003eFor portable H2S concentration checks, this pump hydrogen sulfide detector draws an air sample to an electrochemical sensor. The MH2000-H2S combines adjustable suction, a concentration display and audible, visual and vibration alarms in a 300 g instrument. Select one of three supplied configurations: 0-50, 0-100 or 0-200 ppm.\u003c\/p\u003e\u003ch3\u003eH2S Range and Reading Detail\u003c\/h3\u003e\u003cp\u003eOrder the measurement span required for your work. The three options are separate instrument configurations, rather than three full-scale ranges that can be switched on one detector. All measure hydrogen sulfide through the same internal-pump sampling method.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e0-50 ppm: H2S concentration measurement across a 50 ppm span.\u003c\/li\u003e\n\u003cli\u003e0-100 ppm: H2S concentration measurement with 0.01 ppm resolution.\u003c\/li\u003e\n\u003cli\u003e0-200 ppm: H2S concentration measurement across a 200 ppm span.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe LCD presents the gas type, concentration, unit, time and battery status. Concentration can be displayed in ppm, umol\/mol or mg\/m3, with automatic unit conversion. English and Chinese interfaces are available. A reading in umol\/mol has the same numerical value as a reading in ppm.\u003c\/p\u003e\u003ch3\u003eAdjustable Sampling and Alarm Controls\u003c\/h3\u003e\u003cp\u003eThe built-in pump provides up to 1 L\/min flow, with ten suction settings. Temperature and pressure compensation support the measurement functions. Self-check, zero calibration and factory reset are available through the instrument controls.\u003c\/p\u003e\u003cp\u003eTwo alarm stages have adjustable set points. Sound, light and vibration provide alarm indication, with an audible alarm rated at 85 dB. Follow the supplied instructions and your site's gas-monitoring procedures for calibration, instrument checks and alarm handling.\u003c\/p\u003e\u003ch3\u003eInstrument Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-H2S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured gas\u003c\/td\u003e\n\u003ctd\u003eHydrogen sulfide (H2S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange configurations\u003c\/td\u003e\n\u003ctd\u003e0-50 ppm, 0-100 ppm or 0-200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pump flow\u003c\/td\u003e\n\u003ctd\u003e1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution, 0-100 ppm version\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eppm, umol\/mol and mg\/m3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot-matrix display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed information\u003c\/td\u003e\n\u003ctd\u003eGas type, concentration, unit, time and battery status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm modes\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm levels\u003c\/td\u003e\n\u003ctd\u003eTwo stages with adjustable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003eApproximately 4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eEngineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate instrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecovery time, 0-100 ppm version\u003c\/td\u003e\n\u003ctd\u003e30 seconds or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity and repeatability, 0-100 ppm version\u003c\/td\u003e\n\u003ctd\u003eEach within +\/-1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero drift, 0-100 ppm version\u003c\/td\u003e\n\u003ctd\u003eWithin +\/-1% of full scale per year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003ePower, Package and Configuration\u003c\/h3\u003e\u003cp\u003eThe rechargeable lithium-polymer battery is rated at 3.6 V and 2300 mAh. Charging takes approximately four to six hours. The engineering-plastic housing measures 205 x 75 x 32 mm and is rated IP65.\u003c\/p\u003e\u003cp\u003eThe package includes one detector, a charging\/data cable, an instruction manual and an aluminum carrying case. Data recording and PC data export are optional functions and are not included in this standard configuration. The supplied cable does not by itself enable those functions.\u003c\/p\u003e\u003cp\u003eThis is the standard single-gas H2S configuration. It has no additional CO, oxygen or combustible-gas measurement channels. Product photographs show the shared series housing; demonstration screen labels may differ from the ordered H2S version. The carrying-case photograph illustrates the case and instrument appearance, rather than a two-detector package.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-50 ppm","offer_id":67800430018603,"sku":"GAS-S9K3-01","price":527.25,"currency_code":"USD","in_stock":true},{"title":"0-100 ppm","offer_id":67800430084139,"sku":"GAS-S9K3-02","price":527.25,"currency_code":"USD","in_stock":true},{"title":"0-200 ppm","offer_id":67800430116907,"sku":"GAS-S9K3-03","price":527.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/pump-hydrogen-sulfide-detector-angle.jpg?v=1791535634"},{"product_id":"pump-combustible-gas-detector-mh2000-ex","title":"Pump Combustible Gas Detector - 0-100% LEL","description":"\u003cp\u003eA pump combustible gas detector brings the air sample into the MH2000-EX\/LEL for catalytic combustion measurement. Both sensor configurations cover 0-100% LEL with 1% LEL resolution. Choose Standard or High Performance when ordering; the sensor configuration is supplied in the instrument and is not a software upgrade.\u003c\/p\u003e\u003ch3\u003eChoose the Catalytic Configuration\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eOrder option\u003c\/th\u003e\n\u003cth\u003eSensor configuration\u003c\/th\u003e\n\u003cth\u003eSelection detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eConventional catalytic combustion\u003c\/td\u003e\n\u003ctd\u003eNot recommended for diesel or acetylene environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Performance\u003c\/td\u003e\n\u003ctd\u003eIndustrial catalytic sensor with poisoning resistance\u003c\/td\u003e\n\u003ctd\u003eSupports combustible-gas monitoring in diesel and acetylene environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eThe measured gas and calibration must match the measurement task. Select the sensor option using the gases and conditions in your monitoring procedure. The High Performance configuration provides poisoning resistance; it does not remove the need for instrument checks and calibration.\u003c\/p\u003e\u003ch3\u003ePumped Sampling, Display and Alarms\u003c\/h3\u003e\u003cp\u003eThe internal pump provides up to 1 L\/min flow, with ten suction settings available through the controls. Temperature and pressure compensation support the measurement functions. The dot-matrix LCD shows the gas type, concentration, unit, time and battery status, and the interface can be switched between English and Chinese.\u003c\/p\u003e\u003cp\u003eTwo adjustable alarm stages provide sound, light and vibration indications. The audible alarm is rated at 85 dB. Self-check, zero calibration and factory reset functions are available on the instrument. Follow the supplied instructions and your site's gas-monitoring procedures for setup, checks and alarm handling.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-EX\/LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured gas\u003c\/td\u003e\n\u003ctd\u003eCombustible \/ flammable gas (Ex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eCatalytic combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor configurations\u003c\/td\u003e\n\u003ctd\u003eStandard; High Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pump flow\u003c\/td\u003e\n\u003ctd\u003e1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot-matrix display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed information\u003c\/td\u003e\n\u003ctd\u003eGas type, concentration, unit, time and battery status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm modes\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm levels\u003c\/td\u003e\n\u003ctd\u003eTwo stages with adjustable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003eApproximately 4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eEngineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate instrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003ePower and Supplied Package\u003c\/h3\u003e\u003cp\u003eA 3.6 V, 2300 mAh rechargeable lithium-polymer battery powers the detector. Charging takes approximately four to six hours. The instrument weighs about 300 g and measures 205 x 75 x 32 mm, with an engineering-plastic housing rated IP65.\u003c\/p\u003e\u003cp\u003eThe package includes one detector, a charging\/data cable, an instruction manual and an aluminum carrying case. Data recording and PC data export are optional functions and are not included in these base configurations. A supplied charging\/data cable does not by itself enable those functions.\u003c\/p\u003e\u003cp\u003eThe product photographs show the shared series housing. Demonstration gas labels and screen readings may differ from the ordered combustible-gas configuration. The carrying-case photograph illustrates the case and instrument appearance, rather than a two-detector package.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"Standard","offer_id":67800696750123,"sku":"GAS-E6R8-01","price":465.66,"currency_code":"USD","in_stock":true},{"title":"High Performance","offer_id":67800697339947,"sku":"GAS-E6R8-02","price":687.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/pump-combustible-gas-detector-angle.jpg?v=1791538780"},{"product_id":"pump-methane-detector-mh2000-ch4","title":"Methane Detector with Pump - Catalytic Sensor Options","description":"\u003cp\u003eThe MH2000-CH4 measures methane with a catalytic combustion sensor and an internal sampling pump. This pump methane detector displays CH4 concentration over a 0-100% LEL range, with 1% LEL resolution. It is available in Standard and High Performance sensor configurations, both using the same portable housing and pump controls.\u003c\/p\u003e\u003ch3\u003eReadings and Pump Controls\u003c\/h3\u003e\u003cp\u003eAdjust the pump suction through ten settings, with a maximum flow of 1 L\/min. The LCD dot-matrix display presents the measured gas, concentration, unit, time and battery status. The interface supports English and Chinese, and the instrument includes temperature and pressure compensation.\u003c\/p\u003e\u003cp\u003eTwo alarm stages have adjustable set points. Sound, light and vibration provide alarm indication, with an audible alarm rated at 85 dB. Self-check, zero calibration and factory reset functions are available through the controls. Use the supplied instructions and your methane-monitoring procedure for setup, calibration, checks and alarm handling.\u003c\/p\u003e\u003ch3\u003eChoose Your Catalytic Sensor\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eSensor selection\u003c\/th\u003e\n\u003cth\u003eCH4 range\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eConventional catalytic combustion sensor\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Performance\u003c\/td\u003e\n\u003ctd\u003eIndustrial catalytic sensor with poisoning resistance\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eThe Standard configuration is not recommended for diesel or acetylene environments. High Performance provides poisoning resistance, while retaining the same methane range and resolution. Choose the sensor configuration for the gases and conditions in your measurement procedure. The configuration is selected when ordering and is not a switchable operating mode.\u003c\/p\u003e\u003cp\u003eThis product is supplied as a methane measurement configuration. The sensor grade does not add independently calibrated channels for other gases, and poisoning resistance does not remove the need for instrument checks.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-CH4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured gas\u003c\/td\u003e\n\u003ctd\u003eMethane (CH4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eCatalytic combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor configurations\u003c\/td\u003e\n\u003ctd\u003eStandard; High Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pump flow\u003c\/td\u003e\n\u003ctd\u003e1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot-matrix display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed information\u003c\/td\u003e\n\u003ctd\u003eGas type, concentration, unit, time and battery status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm modes\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm levels\u003c\/td\u003e\n\u003ctd\u003eTwo stages with adjustable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003eApproximately 4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eEngineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate instrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eBattery and Supplied Package\u003c\/h3\u003e\u003cp\u003eA 3.6 V, 2300 mAh rechargeable lithium-polymer battery powers the instrument. Charging takes approximately four to six hours. The engineering-plastic housing is rated IP65 and measures 205 x 75 x 32 mm; the instrument weighs about 300 g.\u003c\/p\u003e\u003cp\u003eThe package includes one detector, a charging\/data cable, an instruction manual and an aluminum carrying case. Data recording and PC export are optional functions and are not included in these base configurations. The charging\/data cable does not by itself enable those functions.\u003c\/p\u003e\u003cp\u003ePhotographs show the shared series housing, so demonstration gas labels and readings may differ from the supplied CH4 version. The carrying-case photograph illustrates the equipment and case appearance, rather than a two-detector package.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"Standard","offer_id":67806159634475,"sku":"GAS-M5T8-01","price":436.18,"currency_code":"USD","in_stock":true},{"title":"High Performance","offer_id":67806159667243,"sku":"GAS-M5T8-02","price":682.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/pump-methane-detector-angle.jpg?v=1791610456"},{"product_id":"pump-ethane-detector-mh2000-c2h6","title":"Infrared Ethane Gas Detector with Adjustable Sampling Pump","description":"\u003cp\u003eThe MH2000-C2H6 is an ethane gas detector with an infrared sensor and an internal sampling pump. Six range configurations cover ppm, percentage by volume and percentage of the lower explosive limit (% LEL). Select the measurement range and unit when ordering to match the ethane concentration you need to measure.\u003c\/p\u003e\u003ch3\u003eSelect an Ethane Measurement Range\u003c\/h3\u003e\u003cp\u003eThe ppm configurations measure from 0-5000 ppm or 0-10000 ppm. Volume-concentration options are 0-5% Vol, 0-50% Vol and 0-100% Vol. A separate 0-100% LEL configuration is available for measurements expressed relative to ethane's lower explosive limit.\u003c\/p\u003e\u003cp\u003eThese are separate ordering configurations, rather than six interchangeable ranges on one instrument. Choose the range for the expected concentration and the reporting unit required by your measurement procedure. A ppm or volume reading should not be treated as a directly interchangeable % LEL reading.\u003c\/p\u003e\u003ch3\u003eAdjustable Pump and Alarm Controls\u003c\/h3\u003e\u003cp\u003eThe internal pump draws a sample into the detector, with ten suction settings and a maximum flow of 1 L\/min. Its LCD dot-matrix screen displays gas type, concentration, measurement unit and time. English and Chinese interface options support instrument setup and daily operation.\u003c\/p\u003e\u003cp\u003eTwo alarm stages have adjustable set points, with sound, light and vibration indications. Temperature and pressure compensation, self-check, zero calibration and factory reset functions are available through the instrument controls. Follow the supplied instructions for calibration, checks and alarm handling, and choose settings appropriate to your ethane-monitoring procedure.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-C2H6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured gas\u003c\/td\u003e\n\u003ctd\u003eEthane (C2H6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eInfrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange configurations\u003c\/td\u003e\n\u003ctd\u003e0-5000 ppm; 0-10000 ppm; 0-5% Vol; 0-50% Vol; 0-100% Vol; 0-100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pump flow\u003c\/td\u003e\n\u003ctd\u003e1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot-matrix display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed information\u003c\/td\u003e\n\u003ctd\u003eGas type, concentration, unit and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm modes\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm levels\u003c\/td\u003e\n\u003ctd\u003eTwo stages with adjustable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument checks\u003c\/td\u003e\n\u003ctd\u003eSelf-check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration control\u003c\/td\u003e\n\u003ctd\u003eZero calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset control\u003c\/td\u003e\n\u003ctd\u003eFactory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eRechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eEngineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate instrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003ePortable Housing and Package\u003c\/h3\u003e\u003cp\u003eThe rechargeable lithium-polymer battery and engineering-plastic housing support portable use. The instrument measures 205 x 75 x 32 mm and weighs approximately 300 g. Its stated operating conditions are -20 to 50 Degree C and 0-95% RH.\u003c\/p\u003e\u003cp\u003eThe package includes one ethane detector, a charging\/data cable, an instruction manual and an aluminum carrying case. Data logging and PC data export are optional functions and are not included in the base configuration. A cable alone does not enable those options.\u003c\/p\u003e\u003cp\u003ePhotographs show the shared series housing; demonstration gas labels and screen readings may differ from the supplied C2H6 version. The carrying-case image shows equipment appearance and does not indicate a two-detector package.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-5000 ppm","offer_id":67806174838827,"sku":"GAS-E7R4-01","price":1721.29,"currency_code":"USD","in_stock":true},{"title":"0-10000 ppm","offer_id":67806174871595,"sku":"GAS-E7R4-02","price":1668.49,"currency_code":"USD","in_stock":true},{"title":"0-5% Vol","offer_id":67806174904363,"sku":"GAS-E7R4-03","price":1724.93,"currency_code":"USD","in_stock":true},{"title":"0-50% Vol","offer_id":67806174937131,"sku":"GAS-E7R4-04","price":1671.91,"currency_code":"USD","in_stock":true},{"title":"0-100% Vol","offer_id":67806174969899,"sku":"GAS-E7R4-05","price":1714.05,"currency_code":"USD","in_stock":true},{"title":"0-100% LEL","offer_id":67806175002667,"sku":"GAS-E7R4-06","price":1773.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/ethane-gas-detector-front.jpg?v=1791611711"},{"product_id":"pump-propane-detector-mh2000-c3h8","title":"Portable Propane Gas Detector - Infrared Pump Sampling","description":"\u003cp\u003eChoose a portable propane gas detector configured for the concentration range your work requires. The MH2000-C3H8 combines an infrared sensor with pump sampling to measure propane, with ordering options in ppm, percentage by volume or percentage of the lower explosive limit (% LEL). Each instrument is supplied for C3H8 with one selected range.\u003c\/p\u003e\u003ch3\u003eChoose the Range and Reporting Unit\u003c\/h3\u003e\u003cp\u003eFor ppm readings, select 0-5000 ppm or 0-10000 ppm. The volume-concentration configurations cover 0-5% Vol, 0-50% Vol or 0-100% Vol. The 0-100% LEL configuration expresses the result relative to propane's lower explosive limit.\u003c\/p\u003e\u003cp\u003eMatch the range to the concentrations you expect and the unit specified in your measurement procedure. Range selection is part of the ordering configuration. Converting between concentration units requires the appropriate gas-specific basis; avoid assuming that the full scale of a volume range is equivalent to the full scale of the LEL configuration.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-C3H8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured gas\u003c\/td\u003e\n\u003ctd\u003ePropane (C3H8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eInfrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range options\u003c\/td\u003e\n\u003ctd\u003e0-5000 ppm; 0-10000 ppm; 0-5% Vol; 0-50% Vol; 0-100% Vol; 0-100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pump flow\u003c\/td\u003e\n\u003ctd\u003e1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot-matrix display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed information\u003c\/td\u003e\n\u003ctd\u003eGas type, concentration, unit and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm indications\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo stages; adjustable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eRechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eEngineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate instrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData functions\u003c\/td\u003e\n\u003ctd\u003eData logging and PC export optional; excluded from base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003ePump, Display and Alarm Settings\u003c\/h3\u003e\u003cp\u003eTen pump suction settings allow adjustment of the sample draw, with a maximum flow of 1 L\/min. The LCD dot-matrix display presents the gas, concentration, measurement unit and time, and the controls support English and Chinese interface options.\u003c\/p\u003e\u003cp\u003eSet the two alarm stages to the thresholds required by your propane-monitoring procedure. Alarm indications use sound, light and vibration. The instrument also provides temperature and pressure compensation, self-check, zero calibration and factory reset controls. Use the supplied instructions for instrument checks, calibration and alarm handling.\u003c\/p\u003e\u003ch3\u003ePower and Supplied Items\u003c\/h3\u003e\u003cp\u003eA rechargeable lithium-polymer battery powers the detector. Its engineering-plastic housing measures 205 x 75 x 32 mm, and the instrument weighs approximately 300 g. Operating conditions are -20 to 50 Degree C and 0-95% RH.\u003c\/p\u003e\u003cp\u003eThe package contains one propane detector, a charging\/data cable, an instruction manual and an aluminum carrying case. Data logging and PC export are optional and excluded from the base configuration.\u003c\/p\u003e\u003cp\u003eImages illustrate the shared series housing. Demonstration screen labels and readings can differ from the supplied propane version; the carrying-case photograph illustrates equipment appearance rather than a two-detector package.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-5000 ppm","offer_id":67806202986539,"sku":"GAS-R8P6-01","price":1710.46,"currency_code":"USD","in_stock":true},{"title":"0-10000 ppm","offer_id":67806203412523,"sku":"GAS-R8P6-02","price":1766.11,"currency_code":"USD","in_stock":true},{"title":"0-5% Vol","offer_id":67806203445291,"sku":"GAS-R8P6-03","price":1714.05,"currency_code":"USD","in_stock":true},{"title":"0-50% Vol","offer_id":67806203478059,"sku":"GAS-R8P6-04","price":1769.83,"currency_code":"USD","in_stock":true},{"title":"0-100% Vol","offer_id":67806203510827,"sku":"GAS-R8P6-05","price":1703.32,"currency_code":"USD","in_stock":true},{"title":"0-100% LEL","offer_id":67806203543595,"sku":"GAS-R8P6-06","price":1758.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/propane-gas-detector-front.jpg?v=1791613332"},{"product_id":"pid-hydrocarbon-detector-mh2000-cxhy","title":"PID Hydrocarbon Detector - PPM and PPB Sensor Options","description":"\u003cp\u003eThe MH2000-CxHy is a portable PID hydrocarbon detector with an internal sampling pump and a choice of PPM or PPB sensor configuration. PPM options cover 0-100, 0-200, 0-1000, 0-2000 and 0-3000 ppm. PPB options cover 0-10 and 0-50 ppm with 0.001 ppm (1 ppb) resolution.\u003c\/p\u003e\u003ch3\u003ePID Measurement and Range Selection\u003c\/h3\u003e\u003cp\u003ePhotoionization detection responds to compounds that can be ionized by the installed lamp. A hydrocarbon-vapor reading therefore depends on the compounds present, the lamp configuration and the calibration basis. For a specific compound or known mixture, confirm target compatibility and the appropriate calibration basis before ordering.\u003c\/p\u003e\u003cp\u003eWhen several detectable compounds are present, the displayed result reflects their combined PID response. The instrument does not identify the individual components of a mixture. Interpret readings using the calibration and response information appropriate to your target vapor.\u003c\/p\u003e\u003cp\u003eChoose the sensor configuration and one measurement range when ordering. The PPB configuration provides 0.001 ppm reading increments for its two lower concentration ranges. PPB identifies the sensor configuration; the range values are expressed in ppm. Resolution describes the reading increment and is distinct from measurement accuracy or a detection limit.\u003c\/p\u003e\u003cp\u003eEach detector is supplied with its selected configuration and full scale. Select a range that covers your expected concentrations and suits the reporting requirements of your procedure.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSensor configuration\u003c\/th\u003e\n\u003cth\u003eOrdering ranges\u003c\/th\u003e\n\u003cth\u003eReading resolution\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPM\u003c\/td\u003e\n\u003ctd\u003e0-100, 0-200, 0-1000, 0-2000, 0-3000 ppm\u003c\/td\u003e\n\u003ctd\u003eRange-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPB\u003c\/td\u003e\n\u003ctd\u003e0-10, 0-50 ppm\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm (1 ppb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eSampling and Alarm Controls\u003c\/h3\u003e\u003cp\u003eAdjust the internal pump through ten suction settings, with a maximum flow of 1 L\/min. The LCD dot-matrix display shows gas type, concentration, unit, battery status and time, with English and Chinese interface options.\u003c\/p\u003e\u003cp\u003eTwo alarm stages have adjustable set points. Sound, light and vibration provide alarm indications, including an audible alarm rated at 85 dB. Temperature and pressure compensation, self-check, zero calibration and factory reset controls support instrument setup. Follow the supplied instructions for calibration, checks and alarm handling.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-CxHy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement configuration\u003c\/td\u003e\n\u003ctd\u003eCxHy hydrocarbon vapors detectable by the configured PID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003ePhotoionization detection (PID)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor configuration\u003c\/td\u003e\n\u003ctd\u003ePPM or PPB, selected when ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range options\u003c\/td\u003e\n\u003ctd\u003ePPM: 0-100\/200\/1000\/2000\/3000 ppm; PPB: 0-10\/50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPB reading resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm (1 ppb), for 0-10 and 0-50 ppm PPB configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pump flow\u003c\/td\u003e\n\u003ctd\u003e1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot-matrix display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed information\u003c\/td\u003e\n\u003ctd\u003eGas type, concentration, unit, battery status and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm indications\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo stages with adjustable set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003eApproximately 4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eEngineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate instrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData functions\u003c\/td\u003e\n\u003ctd\u003eData logging and PC export optional; excluded from base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCharging and Supplied Package\u003c\/h3\u003e\u003cp\u003eThe detector uses a 3.6 V, 2300 mAh rechargeable lithium-polymer battery. Charging takes approximately four to six hours. The engineering-plastic housing is rated IP65 and measures 205 x 75 x 32 mm; instrument weight is about 300 g.\u003c\/p\u003e\u003cp\u003eSupplied items are one detector, a charging\/data cable, an instruction manual and an aluminum carrying case. Data logging and PC export are optional and excluded from this base configuration.\u003c\/p\u003e\u003cp\u003eImages show the shared series housing. Demonstration screen labels and readings may differ from the supplied CxHy configuration, and the carrying-case photograph does not indicate a two-detector package.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"PPM \/ 0-100 ppm","offer_id":67806901796907,"sku":"GAS-L6Q9-01","price":2469.37,"currency_code":"USD","in_stock":true},{"title":"PPM \/ 0-200 ppm","offer_id":67806902222891,"sku":"GAS-L6Q9-02","price":2469.37,"currency_code":"USD","in_stock":true},{"title":"PPM \/ 0-1000 ppm","offer_id":67806902255659,"sku":"GAS-L6Q9-03","price":2547.51,"currency_code":"USD","in_stock":true},{"title":"PPM \/ 0-2000 ppm","offer_id":67806902288427,"sku":"GAS-L6Q9-04","price":2547.51,"currency_code":"USD","in_stock":true},{"title":"PPM \/ 0-3000 ppm","offer_id":67806902321195,"sku":"GAS-L6Q9-05","price":2547.51,"currency_code":"USD","in_stock":true},{"title":"PPB \/ 0-10 ppm","offer_id":67807186944043,"sku":"GAS-L6Q9-06","price":2796.33,"currency_code":"USD","in_stock":true},{"title":"PPB \/ 0-50 ppm","offer_id":67807186976811,"sku":"GAS-L6Q9-07","price":2796.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/pid-hydrocarbon-detector-front.jpg?v=1791618914"},{"product_id":"low-range-ammonia-detector","title":"Low Range Ammonia Gas Detector - 0-10\/20 ppm","description":"\u003cp\u003eMeasure low ammonia concentrations with the MH2000-NH3 Low Range gas detector. This portable electrochemical instrument uses an internal sampling pump and is offered as separate 0-10 ppm and 0-20 ppm versions. It is intended for ambient-air or odor-environment NH3 concentration checks where one of these measuring spans fits the task. Choose one range when ordering; each option is a single-gas ammonia detector.\u003c\/p\u003e\n\u003ch3\u003eChoose Between 0-10 and 0-20 ppm\u003c\/h3\u003e\n\u003cp\u003eThe 0-10 ppm version has a lower maximum measuring span; the 0-20 ppm version covers a broader low-concentration interval. Select the range for the expected NH3 concentration and the measurement procedure. The range label identifies the version supplied. A detector ordered in one range does not automatically switch to the other range.\u003c\/p\u003e\n\u003cp\u003eThis instrument reports ammonia concentration. It does not measure general odor intensity or identify all gases contributing to an odor. Keep the target gas and the expected concentration explicit when selecting the instrument and sampling arrangement.\u003c\/p\u003e\n\u003ch3\u003ePump Sampling and Adjustable Alarms\u003c\/h3\u003e\n\u003cp\u003eThe internal pump draws a sample to the electrochemical sensor, with flow up to 1 L\/min and ten adjustment settings. The LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. The operating interface supports English and Chinese, and concentration can be displayed in ppm or mg\/m³.\u003c\/p\u003e\n\u003cp\u003eTwo alarm stages have adjustable setpoints. Sound, light and vibration outputs include an 85 dB sound alarm and blue low-alarm\/red high-alarm lights. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup. Use the supplied instructions and the procedure for the intended measurement.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor configurations\u003c\/td\u003e\n\u003ctd\u003eLow Range (Atmospheric), single-gas configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-10 and 0-20 ppm, single-gas ammonia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eppm \/ mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecording and Optional Sampling Equipment\u003c\/h3\u003e\n\u003cp\u003eData logging and PC export are optional and are not included in this base configuration. If stored measurement records are needed, ask about the recording option before ordering. Filters, drying accessories and high-temperature probes are separate sampling choices; their suitability and inclusion depend on the intended arrangement.\u003c\/p\u003e\n\u003cp\u003eThe instrument weighs 300 g and uses a rechargeable lithium-polymer battery. Gallery photos illustrate the shared housing and carrying-case views. The image with two instruments does not represent a two-unit package, and a connected cable does not establish that PC data export is included.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-10 ppm","offer_id":67815748534315,"sku":"GAS-A6R8-01","price":1589.39,"currency_code":"USD","in_stock":true},{"title":"0-20 ppm","offer_id":67815748567083,"sku":"GAS-A6R8-02","price":1589.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/low-range-ammonia-detector-pump-front.jpg?v=1791784099"},{"product_id":"pump-chlorine-detector-mh2000-cl2","title":"Chlorine Gas Detector with Pump - Standard \u0026 High Precision","description":"\u003cp\u003eSelect the chlorine sensor configuration and measuring range for the sampling task. The MH2000-CL2 uses an internal pump and an electrochemical sensor to measure Cl2 concentration. Standard versions offer five separate ranges from 0-10 to 0-200 ppm; High Precision versions are available in 0-10, 0-50 and 0-100 ppm. Each order option is one portable, single-gas chlorine detector with its selected configuration and span.\u003c\/p\u003e\n\u003ch3\u003eStandard and High Precision Options\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSensor configuration\u003c\/th\u003e\n\u003cth\u003eAvailable measuring ranges\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e0-10 \/ 20 \/ 50 \/ 100 \/ 200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Precision\u003c\/td\u003e\n\u003ctd\u003e0-10 \/ 50 \/ 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eA Standard 0-10 ppm option and a High Precision 0-10 ppm option are different sensor configurations despite sharing the same measuring span. Choose the configuration and range together; the instrument supplied does not automatically cover every option on this page. The range describes the concentration interval of the selected version, rather than an interchangeable setting.\u003c\/p\u003e\n\u003ch3\u003eInternal Pump, Display and Alerts\u003c\/h3\u003e\n\u003cp\u003eSampling flow reaches up to 1 L\/min, with ten pump adjustment settings. An LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese operating interfaces are available, with ppm and mg\/m³ concentration displays.\u003c\/p\u003e\n\u003cp\u003eTwo alarm stages have adjustable setpoints, using sound, light and vibration outputs. The sound alarm is 85 dB; blue and red lights indicate low and high alarms. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup. Operate the selected chlorine version according to its supplied instructions and the sampling procedure.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-CL2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor configurations\u003c\/td\u003e\n\u003ctd\u003eStandard or High Precision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard range options\u003c\/td\u003e\n\u003ctd\u003e0-10, 0-20, 0-50, 0-100 and 0-200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Precision range options\u003c\/td\u003e\n\u003ctd\u003e0-10, 0-50 and 0-100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eppm \/ mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecording and Sampling Package\u003c\/h3\u003e\n\u003cp\u003eData logging and PC export are optional and are not included in this base configuration. Where stored readings are needed, ask about the recording configuration before ordering. Filters, drying accessories and high-temperature probes are separate sampling choices; their inclusion depends on the selected package.\u003c\/p\u003e\n\u003cp\u003eThe target gas is chlorine, Cl2. Select an instrument configured for the gas named in the measurement requirement; this page does not establish chlorine-dioxide or multi-gas measurement. Gallery images show the shared pump-detector housing. A connected cable does not indicate included PC export, and the carrying-case image does not represent a two-detector package.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"Standard \/ 0-10 ppm","offer_id":67815906705451,"sku":"GAS-C7L4-01","price":674.3,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-20 ppm","offer_id":67815906738219,"sku":"GAS-C7L4-02","price":674.3,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-50 ppm","offer_id":67815906770987,"sku":"GAS-C7L4-03","price":698.84,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-100 ppm","offer_id":67815906803755,"sku":"GAS-C7L4-04","price":698.84,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-200 ppm","offer_id":67815906836523,"sku":"GAS-C7L4-05","price":867.98,"currency_code":"USD","in_stock":true},{"title":"High Precision \/ 0-10 ppm","offer_id":67815906869291,"sku":"GAS-C7L4-06","price":1322.13,"currency_code":"USD","in_stock":true},{"title":"High Precision \/ 0-50 ppm","offer_id":67815906902059,"sku":"GAS-C7L4-07","price":1322.13,"currency_code":"USD","in_stock":true},{"title":"High Precision \/ 0-100 ppm","offer_id":67815906934827,"sku":"GAS-C7L4-08","price":1322.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/chlorine-detector-pump-angle.jpg?v=1791791423"},{"product_id":"low-range-hydrogen-detector","title":"Low Range Hydrogen Detector - 0.001 ppm Resolution","description":"\u003cp\u003eThe MH2000-H2 Low Range detector measures hydrogen concentration using an electrochemical sensor and an internal sampling pump. Choose a 0-10 ppm or 0-20 ppm version, both with 0.001 ppm resolution. This is a portable, single-gas H2 configuration for low-concentration measurement tasks that fit one of these spans. Select the measuring range when ordering; one instrument is supplied with the selected version.\u003c\/p\u003e\n\u003ch3\u003eTwo Low Measuring Ranges\u003c\/h3\u003e\n\u003cp\u003eThe 0-10 ppm option has a lower maximum measuring span, while the 0-20 ppm option covers a broader low-concentration interval. Both offer the same stated 0.001 ppm resolution. Match the required hydrogen range to the concentration expected in the sample and the measurement procedure. A detector ordered in one range does not automatically switch to the other version.\u003c\/p\u003e\n\u003ch3\u003eSampling and On-Instrument Controls\u003c\/h3\u003e\n\u003cp\u003eThe pump provides up to 1 L\/min flow and ten adjustment settings. The LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available, and hydrogen concentration can be displayed in ppm or mg\/m³.\u003c\/p\u003e\n\u003cp\u003eTwo alarm stages have adjustable setpoints, with sound, light and vibration outputs. The sound alarm is 85 dB; blue and red lights indicate low and high alarms. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup. Follow the supplied instructions for the low-range H2 configuration and the procedure used for the measurement.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-H2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eHydrogen (H2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Precision, Low Range, single-gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-10 or 0-20 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm for both Low Range options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eppm \/ mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecording and Sampling Options\u003c\/h3\u003e\n\u003cp\u003eData logging and PC export are optional and are not included in this base configuration. Where stored records are required, ask about the recording option before ordering. Sampling filters, drying accessories and high-temperature probes are separate package choices; their suitability and inclusion depend on the intended arrangement.\u003c\/p\u003e\n\u003cp\u003eThe instrument weighs 300 g and uses a rechargeable lithium-polymer battery. Gallery photographs illustrate the shared pump-detector housing, including views with a carrying case. The case image does not represent a two-instrument package, and a connected cable does not establish that PC export is included.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-10 ppm","offer_id":67815949926443,"sku":"GAS-H4L8-01","price":2241.07,"currency_code":"USD","in_stock":true},{"title":"0-20 ppm","offer_id":67815949959211,"sku":"GAS-H4L8-02","price":2166.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/low-range-hydrogen-detector-pump-angle.jpg?v=1791792797"},{"product_id":"pump-hydrogen-detector-mh2000-h2","title":"Hydrogen Gas Detector with Pump - 1000 to 40000 ppm","description":"\u003cp\u003eChoose the MH2000-H2 pump hydrogen detector in the measuring span required for the sample. Six Standard electrochemical versions are available: 0-1000, 0-2000, 0-5000, 0-10000, 0-20000 and 0-40000 ppm. The internal pump draws a gas sample to the sensor, and the instrument displays hydrogen concentration on its LCD screen. Each range is a separate supplied version of this portable, single-gas H2 detector.\u003c\/p\u003e\n\u003ch3\u003eSelect One of Six Hydrogen Ranges\u003c\/h3\u003e\n\u003cp\u003eThe range selector identifies the maximum concentration span of the version supplied. Select a 1000, 2000, 5000, 10000, 20000 or 40000 ppm option for the expected concentration and the measurement procedure. One detector does not automatically cover every range shown on this page. Keep the target gas and the required measuring interval explicit when choosing the instrument.\u003c\/p\u003e\n\u003ch3\u003eControls for Pump Sampling\u003c\/h3\u003e\n\u003cp\u003ePump flow reaches up to 1 L\/min, with ten adjustment settings. The LCD dot-matrix display presents the gas type, concentration, unit, battery level and time. The operating interface supports English and Chinese, and concentration can be displayed in ppm or mg\/m³. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup.\u003c\/p\u003e\n\u003cp\u003eTwo alarm stages have adjustable setpoints. Sound, light and vibration provide multiple alert outputs, including an 85 dB sound alarm and blue low-alarm\/red high-alarm lights. Operate the selected H2 version according to its supplied instructions and the sampling procedure for the work.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-H2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eHydrogen (H2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-1000, 0-2000, 0-5000, 0-10000, 0-20000 or 0-40000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eppm \/ mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSupplied Configuration and Optional Recording\u003c\/h3\u003e\n\u003cp\u003eThe instrument has a rechargeable lithium-polymer battery and weighs 300 g. Data logging and PC export are optional and are not included in this base configuration. If recorded readings are needed, ask about the recording package before ordering. Sampling filters, drying accessories and high-temperature probes are separate choices; do not infer that they are included in every configuration.\u003c\/p\u003e\n\u003cp\u003eGallery photos illustrate the shared instrument housing. A connected cable does not indicate included PC export, and the carrying-case photo does not represent a two-detector order. Select the required hydrogen range as a separate order option.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-1000 ppm","offer_id":67815952613419,"sku":"GAS-H8P4-01","price":695.86,"currency_code":"USD","in_stock":true},{"title":"0-2000 ppm","offer_id":67815952646187,"sku":"GAS-H8P4-02","price":695.86,"currency_code":"USD","in_stock":true},{"title":"0-5000 ppm","offer_id":67815952678955,"sku":"GAS-H8P4-03","price":695.86,"currency_code":"USD","in_stock":true},{"title":"0-10000 ppm","offer_id":67815952711723,"sku":"GAS-H8P4-04","price":973.06,"currency_code":"USD","in_stock":true},{"title":"0-20000 ppm","offer_id":67815952744491,"sku":"GAS-H8P4-05","price":973.06,"currency_code":"USD","in_stock":true},{"title":"0-40000 ppm","offer_id":67815952777259,"sku":"GAS-H8P4-06","price":973.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/hydrogen-detector-pump-front.jpg?v=1791793173"},{"product_id":"pump-nitric-oxide-detector","title":"Nitric Oxide Gas Detector with Pump - 20 to 2000 ppm","description":"\u003cp\u003eThe MH2000-NO pump detector measures nitric oxide concentration using an electrochemical sensor. Seven order options cover four Standard ranges and three High Performance ranges. Choose the performance grade and measuring range together for the NO measurement task. One instrument is supplied with the selected sensor configuration and span.\u003c\/p\u003e\n\u003ch3\u003eSelect the Grade and Measuring Range\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eMeasuring ranges\u003c\/th\u003e\n\u003cth\u003eApplication limit\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e0-20 \/ 50 \/ 100 \/ 250 ppm\u003c\/td\u003e\n\u003ctd\u003eRoutine NO concentration measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Performance\u003c\/td\u003e\n\u003ctd\u003e0-500 \/ 1000 \/ 2000 ppm\u003c\/td\u003e\n\u003ctd\u003eNot suitable for flue-gas environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe High Performance options on this page cannot be used in flue-gas environments. Select the separate flue-gas-specific NO configuration when that application is required. Each measuring span belongs to an individual order option; the supplied instrument does not automatically switch between all seven versions. The grade name identifies the sensor configuration and does not establish a numerical accuracy value.\u003c\/p\u003e\n\u003ch3\u003ePortable Sampling and Alarm Controls\u003c\/h3\u003e\n\u003cp\u003eThe internal pump delivers up to 1 L\/min with ten adjustment settings. An LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available. Concentration units include μmol\/mol, ppm and mg\/m³, with 1 μmol\/mol equivalent to 1 ppm.\u003c\/p\u003e\n\u003cp\u003eTwo alarm stages have adjustable setpoints. Sound, light and vibration provide the alarm outputs, including an 85 dB sound alarm and blue\/red alarm lights. Temperature and pressure compensation, self-check, zero calibration and factory reset are provided for instrument setup. Use the controls according to the supplied instructions for the selected NO sensor.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eNitric oxide (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor configurations\u003c\/td\u003e\n\u003ctd\u003eStandard or High Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard range options\u003c\/td\u003e\n\u003ctd\u003e0-20, 0-50, 0-100 and 0-250 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Performance range options\u003c\/td\u003e\n\u003ctd\u003e0-500, 0-1000 and 0-2000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Performance application limit\u003c\/td\u003e\n\u003ctd\u003eNot suitable for flue-gas environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eμmol\/mol \/ ppm \/ mg\/m³; 1 μmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecording and Order Details\u003c\/h3\u003e\n\u003cp\u003eData logging and USB export are optional and excluded from this base configuration. Ask about the recording option before ordering if stored measurements are needed. The rechargeable lithium-polymer battery takes 4-6 hours to charge, and the instrument weighs 300 g.\u003c\/p\u003e\n\u003cp\u003eGallery views illustrate the shared pump-detector housing. Screen readings are illustrative. The carrying-case photograph does not represent a two-instrument package, and a connected cable does not establish included PC export.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"Standard \/ 0-20 ppm","offer_id":67816381808683,"sku":"GAS-N5R9-01","price":740.11,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-50 ppm","offer_id":67816381841451,"sku":"GAS-N5R9-02","price":740.11,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-100 ppm","offer_id":67816381874219,"sku":"GAS-N5R9-03","price":740.11,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-250 ppm","offer_id":67816381906987,"sku":"GAS-N5R9-04","price":745.71,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-500 ppm","offer_id":67816381939755,"sku":"GAS-N5R9-05","price":957.86,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-1000 ppm","offer_id":67816381972523,"sku":"GAS-N5R9-06","price":991.11,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-2000 ppm","offer_id":67816382005291,"sku":"GAS-N5R9-07","price":998.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/nitric-oxide-detector-pump-angle.jpg?v=1791798040"},{"product_id":"ambient-nitric-oxide-detector","title":"Ambient Nitric Oxide Detector - 0.001 ppm Resolution","description":"\u003cp\u003eChoose a 0-1 ppm or 0-10 ppm version of the MH2000-NO ambient nitric oxide detector for low-concentration measurements. Both versions use an electrochemical sensor, internal pump sampling and 0.001 ppm resolution. This High Precision configuration is a portable, single-gas NO instrument intended for ambient-air measurement tasks within the selected span.\u003c\/p\u003e\n\u003ch3\u003eLow Ranges for Ambient-Air Measurements\u003c\/h3\u003e\n\u003cp\u003eThe 0-1 ppm option has a lower maximum measuring span; the 0-10 ppm version covers a broader low-concentration interval. Resolution is 0.001 ppm on both options. Match the ordered span to the expected sample concentration and measurement procedure. Resolution describes the display increment and does not establish a detection limit or numerical measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eEach order supplies one instrument configured for its selected range. It does not automatically cover both versions. Select this ambient-air configuration for its stated application, and choose the separate flue-gas-specific version when the measurement task involves flue gas.\u003c\/p\u003e\n\u003ch3\u003eDisplay, Compensation and Alerts\u003c\/h3\u003e\n\u003cp\u003eThe LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese operating interfaces are available. Concentrations can be displayed in μmol\/mol, ppm or mg\/m³, with 1 μmol\/mol equivalent to 1 ppm.\u003c\/p\u003e\n\u003cp\u003eTemperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup. Two alarm stages allow the setpoints to be adjusted, with sound, light and vibration outputs. The sound alarm is 85 dB, and blue\/red lights indicate the two alarm levels. Follow the instrument instructions for the selected low-range NO configuration.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eNitric oxide (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Precision, ambient-air, single-gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-1 or 0-10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm for both ambient Low Range options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eμmol\/mol \/ ppm \/ mg\/m³; 1 μmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSampling and Recording Options\u003c\/h3\u003e\n\u003cp\u003eThe internal pump provides up to 1 L\/min flow and ten adjustment settings. The 300 g instrument uses a rechargeable lithium-polymer battery. Filters, drying accessories and sampling probes are separate package choices for the measurement arrangement.\u003c\/p\u003e\n\u003cp\u003eData logging and PC export are optional and excluded from this base configuration. Gallery photographs illustrate the shared housing and its controls. The carrying-case view does not represent a two-instrument package, and a connected cable does not indicate included PC export.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-1 ppm","offer_id":67816391213099,"sku":"GAS-N3A8-01","price":1334.15,"currency_code":"USD","in_stock":true},{"title":"0-10 ppm","offer_id":67816391245867,"sku":"GAS-N3A8-02","price":1380.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/ambient-nitric-oxide-detector-pump-front.jpg?v=1791798092"},{"product_id":"flue-gas-nitric-oxide-detector","title":"Nitric Oxide Detector for Flue Gas - Up to 5000 ppm","description":"\u003cp\u003eMeasure nitric oxide with the MH2000-NO flue-gas-specific detector, available in four ranges from 0-500 to 0-5000 ppm. This portable, single-gas instrument uses an electrochemical sensor and an internal sampling pump. Its High Performance sensor configuration is intended for flue-gas NO measurement and includes interference resistance for that application.\u003c\/p\u003e\n\u003ch3\u003eFlue-Gas Configuration and Range Selection\u003c\/h3\u003e\n\u003cp\u003eChoose 0-500, 0-1000, 0-2000 or 0-5000 ppm when ordering. One detector is supplied with the selected measuring span. The interference-resistant configuration does not establish complete immunity to every interfering gas, and the instrument measures NO rather than total nitrogen oxides.\u003c\/p\u003e\n\u003cp\u003eThis product uses the flue-gas-specific sensor configuration. The separate High Performance NO options designated unsuitable for flue-gas environments serve a different application. Select the sensor configuration first, then the measuring span required by the procedure.\u003c\/p\u003e\n\u003ch3\u003eSampling Arrangement\u003c\/h3\u003e\n\u003cp\u003eThe instrument has up to 1 L\/min pump flow with ten adjustment settings. Probe temperature capability, filters and drying accessories are separate sampling-package choices. The detector's operating temperature is -20°C to 50°C; this value is not a rated temperature for a probe in a hot flue. Choose the sampling arrangement for the application before ordering.\u003c\/p\u003e\n\u003cp\u003eThe housing weighs 300 g and measures 205 x 75 x 32 mm. A rechargeable lithium-polymer battery powers the instrument. Data logging and USB export are optional and excluded from this base configuration.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eNitric oxide (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Performance, flue-gas-specific, single-gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-500, 0-1000, 0-2000 or 0-5000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference resistance\u003c\/td\u003e\n\u003ctd\u003eInterference-resistant sensor configuration for flue-gas NO measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling package\u003c\/td\u003e\n\u003ctd\u003eApplication-specific probe, filter and drying accessories are separate choices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eμmol\/mol \/ ppm \/ mg\/m³; 1 μmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eReadings and Instrument Controls\u003c\/h3\u003e\n\u003cp\u003eThe LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available, and units include μmol\/mol, ppm and mg\/m³. Two adjustable alarm stages use sound, light and vibration, including an 85 dB sound alarm and blue\/red lights.\u003c\/p\u003e\n\u003cp\u003eTemperature and pressure compensation, self-check, zero calibration and factory reset are included. Operate the selected version according to its supplied instructions and sampling procedure. Gallery images show the shared housing; the case photograph does not represent a two-instrument package or establish included sampling probes.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-500 ppm","offer_id":67816403107883,"sku":"GAS-N9F2-01","price":1325.81,"currency_code":"USD","in_stock":true},{"title":"0-1000 ppm","offer_id":67816403140651,"sku":"GAS-N9F2-02","price":1371.53,"currency_code":"USD","in_stock":true},{"title":"0-2000 ppm","offer_id":67816403173419,"sku":"GAS-N9F2-03","price":1398.6,"currency_code":"USD","in_stock":true},{"title":"0-5000 ppm","offer_id":67816403206187,"sku":"GAS-N9F2-04","price":1438.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/flue-gas-nitric-oxide-detector-pump-angle.jpg?v=1791798126"},{"product_id":"low-range-nitrogen-dioxide-detector","title":"Nitrogen Dioxide Detector - Low Range 1 \u0026 5 ppm","description":"\u003cp\u003eThe MH2000-NO2 Low Range detector measures nitrogen dioxide in ambient air with an electrochemical sensor and an internal sampling pump. Two separate versions are available: 0-1 ppm and 0-5 ppm. Both have 0.001 ppm resolution. Choose the span that covers the sample concentration expected in the measurement procedure.\u003c\/p\u003e\n\u003ch3\u003eChoose the 1 ppm or 5 ppm Version\u003c\/h3\u003e\n\u003cp\u003eThe 0-1 ppm version provides a lower maximum measuring span, while the 0-5 ppm option covers a broader low-concentration interval. Each instrument is configured for the range selected when ordering. The supplied detector does not automatically switch between the two versions.\u003c\/p\u003e\n\u003cp\u003eResolution is the stated reading increment. The 0.001 ppm value does not establish a detection limit or a numerical accuracy specification. This High Precision, single-gas configuration measures NO2 for ambient-air tasks. Choose the separate flue-gas-specific NO2 version when that application is required.\u003c\/p\u003e\n\u003ch3\u003eReadings and Alarm Settings\u003c\/h3\u003e\n\u003cp\u003eAn LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese operating interfaces are available. Concentration units include μmol\/mol, ppm and mg\/m³, with 1 μmol\/mol equivalent to 1 ppm.\u003c\/p\u003e\n\u003cp\u003eTwo alarm stages allow the setpoints to be adjusted. Sound, light and vibration provide the alarm outputs, including an 85 dB sound alarm and blue\/red alarm lights. Self-check, zero calibration, factory reset, and temperature and pressure compensation support instrument setup. Use these controls according to the supplied instructions for the selected low-range NO2 configuration.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-NO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eNitrogen dioxide (NO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Precision, ambient-air, single-gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-1 or 0-5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm for both Low Range options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eμmol\/mol \/ ppm \/ mg\/m³; 1 μmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSampling and Recording Choices\u003c\/h3\u003e\n\u003cp\u003eThe internal pump offers up to 1 L\/min flow and ten adjustment settings. The 300 g detector uses a 3.6 V, 2300 mAh rechargeable lithium-polymer battery, with a charging time of 4-6 hours. Sampling filters, drying accessories and probes are separate package choices.\u003c\/p\u003e\n\u003cp\u003eData logging and PC export are optional and excluded from this base configuration. Gallery photographs show the shared pump-detector housing and its controls. Screen readings are illustrative; the carrying-case view does not represent two supplied instruments, and a connected cable does not establish included PC export.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-1 ppm","offer_id":67826222268459,"sku":"GAS-D4A8-01","price":1356.91,"currency_code":"USD","in_stock":true},{"title":"0-5 ppm","offer_id":67826222301227,"sku":"GAS-D4A8-02","price":1356.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/low-range-nitrogen-dioxide-detector-pump-angle.jpg?v=1791855925"},{"product_id":"flue-gas-nitrogen-dioxide-detector","title":"Nitrogen Dioxide Detector for Flue Gas - 500 to 5000 ppm","description":"\u003cp\u003eSelect a MH2000-NO2 nitrogen dioxide detector configured for flue-gas measurement. This portable, single-gas instrument uses an electrochemical sensor and an internal sampling pump, with four order options: 0-500, 0-1000, 0-2000 or 0-5000 ppm. One detector is supplied with the High Performance sensor configuration and measuring span selected when ordering.\u003c\/p\u003e\n\u003ch3\u003eFour Flue-Gas Measuring Ranges\u003c\/h3\u003e\n\u003cp\u003eChoose the span that covers the nitrogen dioxide concentration required by the measurement procedure. The detector does not automatically switch between all four versions. Its measured gas is NO2; the configuration does not establish measurement of nitric oxide, NO, or total nitrogen oxides.\u003c\/p\u003e\n\u003cp\u003eThis product uses the flue-gas-specific sensor configuration. The ambient Low Range NO2 version serves low-concentration ambient-air measurements. Matching the gas, application and measuring span helps identify the correct instrument before selecting a sampling package.\u003c\/p\u003e\n\u003ch3\u003ePlan the Sampling Package\u003c\/h3\u003e\n\u003cp\u003eThe pump delivers up to 1 L\/min flow and has ten adjustment settings. Sampling probes, filters and drying accessories are separate choices for the intended arrangement. The detector's operating temperature is -20°C to 50°C. This value describes the instrument environment and is not a temperature rating for a probe placed in a hot flue.\u003c\/p\u003e\n\u003cp\u003eThe housing measures 205 x 75 x 32 mm and weighs 300 g. A rechargeable lithium-polymer battery powers the instrument. Data logging and USB export are optional and excluded from this base configuration. Select the recording option before ordering if stored measurements are required.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-NO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eNitrogen dioxide (NO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Performance, flue-gas-specific, single-gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-500, 0-1000, 0-2000 or 0-5000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling package\u003c\/td\u003e\n\u003ctd\u003eApplication-specific probe, filter and drying accessories are separate choices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eμmol\/mol \/ ppm \/ mg\/m³; 1 μmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDisplay and Instrument Controls\u003c\/h3\u003e\n\u003cp\u003eThe LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available. Concentration units include μmol\/mol, ppm and mg\/m³. Two alarm stages have adjustable setpoints, with sound, light and vibration outputs.\u003c\/p\u003e\n\u003cp\u003eTemperature and pressure compensation, self-check, zero calibration and factory-reset controls are provided. Follow the instrument instructions for the selected NO2 sensor and sampling arrangement. Gallery images show the shared pump-detector housing. A case photograph does not represent a two-instrument package or establish included sampling probes.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-500 ppm","offer_id":67826222989355,"sku":"GAS-D9F6-01","price":1327.58,"currency_code":"USD","in_stock":true},{"title":"0-1000 ppm","offer_id":67826223022123,"sku":"GAS-D9F6-02","price":1327.58,"currency_code":"USD","in_stock":true},{"title":"0-2000 ppm","offer_id":67826223054891,"sku":"GAS-D9F6-03","price":1356.91,"currency_code":"USD","in_stock":true},{"title":"0-5000 ppm","offer_id":67826223087659,"sku":"GAS-D9F6-04","price":1382.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/flue-gas-nitrogen-dioxide-detector-pump-front.jpg?v=1791855984"},{"product_id":"pump-sulfur-dioxide-detector","title":"Sulfur Dioxide Gas Detector with Pump - 20 to 2000 ppm","description":"\u003cp\u003eThe MH2000-SO2 pump detector measures sulfur dioxide with an electrochemical sensor. Choose one of three Standard ranges or four High Performance ranges to match the SO2 concentration span required by the measurement task. Both configurations on this page are for applications outside flue-gas environments.\u003c\/p\u003e\n\u003ch3\u003eStandard and High Performance Options\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSensor configuration\u003c\/th\u003e\n\u003cth\u003eMeasuring ranges\u003c\/th\u003e\n\u003cth\u003eApplication limit\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e0-20 \/ 50 \/ 100 ppm\u003c\/td\u003e\n\u003ctd\u003eNot suitable for flue gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Performance\u003c\/td\u003e\n\u003ctd\u003e0-200 \/ 500 \/ 1000 \/ 2000 ppm\u003c\/td\u003e\n\u003ctd\u003eNot suitable for flue gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSelect the performance grade and measuring range together when ordering. One instrument is supplied with the chosen sensor and span; it does not automatically switch between all seven versions. The High Performance grade identifies a configuration and does not establish a numerical accuracy value. Choose the separate flue-gas-specific SO2 configuration when that application is required.\u003c\/p\u003e\n\u003ch3\u003eSampling, Readings and Controls\u003c\/h3\u003e\n\u003cp\u003eAn internal pump delivers up to 1 L\/min flow with ten adjustment settings. The LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available. Concentration units include μmol\/mol, ppm and mg\/m³, with 1 μmol\/mol equivalent to 1 ppm.\u003c\/p\u003e\n\u003cp\u003eTwo adjustable alarm stages use sound, light and vibration outputs. The sound alarm is 85 dB, and blue\/red lights indicate the alarm levels. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup. Follow the supplied instructions for the selected SO2 sensor configuration.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-SO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eSulfur dioxide (SO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor configurations\u003c\/td\u003e\n\u003ctd\u003eStandard or High Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard measuring range options\u003c\/td\u003e\n\u003ctd\u003e0-20, 0-50 or 0-100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Performance range options\u003c\/td\u003e\n\u003ctd\u003e0-200, 0-500, 0-1000 or 0-2000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication limit\u003c\/td\u003e\n\u003ctd\u003eNeither configuration is suitable for flue-gas environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eμmol\/mol \/ ppm \/ mg\/m³; 1 μmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecording and Package Choices\u003c\/h3\u003e\n\u003cp\u003eData logging and PC export are optional and excluded from this base configuration. Select the recording option before ordering if stored readings are required. The 300 g instrument uses a rechargeable lithium-polymer battery, with a charging time of 4-6 hours.\u003c\/p\u003e\n\u003cp\u003eFilters, drying accessories and sampling probes are separate package choices. Gallery photographs show the shared pump-detector housing; screen readings are illustrative. A case photograph does not represent two supplied instruments, and a connected cable does not establish included PC export.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"Standard \/ 0-20 ppm","offer_id":67826854723627,"sku":"GAS-S6P8-01","price":679.92,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-50 ppm","offer_id":67826854756395,"sku":"GAS-S6P8-02","price":701.85,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-100 ppm","offer_id":67826854789163,"sku":"GAS-S6P8-03","price":701.85,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-200 ppm","offer_id":67826854821931,"sku":"GAS-S6P8-04","price":947.93,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-500 ppm","offer_id":67826854854699,"sku":"GAS-S6P8-05","price":978.37,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-1000 ppm","offer_id":67826854887467,"sku":"GAS-S6P8-06","price":978.37,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-2000 ppm","offer_id":67826854920235,"sku":"GAS-S6P8-07","price":992.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/pump-sulfur-dioxide-detector-pump-front.jpg?v=1791858872"},{"product_id":"ambient-sulfur-dioxide-detector","title":"Ambient Sulfur Dioxide Detector - 0.001 ppm Resolution","description":"\u003cp\u003eMeasure low sulfur dioxide concentrations in ambient air with the MH2000-SO2 Low Range detector. Choose a 0-1 ppm or 0-5 ppm version, both with 0.001 ppm resolution. This High Precision, single-gas SO2 configuration uses an electrochemical sensor and an internal sampling pump.\u003c\/p\u003e\n\u003ch3\u003eTwo Ambient Measuring Spans\u003c\/h3\u003e\n\u003cp\u003eThe 0-1 ppm option has a lower maximum measuring span, while the 0-5 ppm option covers a broader low-concentration interval. Match the ordered span to the concentration expected in the sample and the measurement procedure. Each order supplies one instrument configured for the selected version; it does not automatically cover both ranges.\u003c\/p\u003e\n\u003cp\u003eResolution describes the stated reading increment. The 0.001 ppm value does not establish a detection limit or numerical measurement accuracy. This ambient-air configuration serves low-concentration SO2 tasks. Select the separate flue-gas-specific or biogas-specific configuration when the application requires one of those sensor arrangements.\u003c\/p\u003e\n\u003ch3\u003eDisplay and Alarm Setup\u003c\/h3\u003e\n\u003cp\u003eThe LCD dot-matrix display shows gas type, concentration, unit, battery level and time. English and Chinese operating interfaces are available. Concentration can be displayed in μmol\/mol, ppm or mg\/m³, with 1 μmol\/mol equivalent to 1 ppm.\u003c\/p\u003e\n\u003cp\u003eTwo alarm stages allow the setpoints to be adjusted. Sound, light and vibration provide the outputs, including an 85 dB sound alarm and blue\/red alarm lights. Self-check, zero calibration, factory reset, and temperature and pressure compensation are provided. Operate the controls according to the supplied instructions for the selected Low Range SO2 version.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-SO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eSulfur dioxide (SO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Precision, ambient-air, single-gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-1 or 0-5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm for both Ambient Low Range options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eμmol\/mol \/ ppm \/ mg\/m³; 1 μmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSampling and Recording Options\u003c\/h3\u003e\n\u003cp\u003eThe internal pump provides up to 1 L\/min flow and ten adjustment settings. The 300 g instrument uses a rechargeable lithium-polymer battery. Filters, drying accessories and sampling probes are separate choices for the intended sampling arrangement.\u003c\/p\u003e\n\u003cp\u003eData logging and PC export are optional and excluded from this base configuration. Gallery images illustrate the common housing and controls. The case view does not represent two supplied instruments, and a connected cable does not indicate included PC export.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-1 ppm","offer_id":67826857017387,"sku":"GAS-S3A7-01","price":1334.15,"currency_code":"USD","in_stock":true},{"title":"0-5 ppm","offer_id":67826857050155,"sku":"GAS-S3A7-02","price":1377.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/ambient-sulfur-dioxide-detector-pump-front.jpg?v=1791858925"},{"product_id":"flue-gas-sulfur-dioxide-detector","title":"Flue Gas SO2 Detector - 200 to 5000 ppm","description":"\u003cp\u003eThe MH2000-SO2 flue-gas-specific detector measures sulfur dioxide with an electrochemical sensor and internal pump sampling. Its High Performance, interference-resistant configuration is available in five ranges: 0-200, 0-500, 0-1000, 0-2000 and 0-5000 ppm. One single-gas instrument is supplied with the measuring span selected when ordering.\u003c\/p\u003e\n\u003ch3\u003eSelect the Flue-Gas Sensor and Range\u003c\/h3\u003e\n\u003cp\u003eMatch the measuring span to the sulfur dioxide concentration required by the sampling procedure. The supplied instrument does not automatically switch between the five order options. Interference resistance identifies this sensor configuration and does not establish complete immunity to every interfering gas.\u003c\/p\u003e\n\u003cp\u003eThe flue-gas-specific sensor serves a different application from the Standard and High Performance SO2 versions designated unsuitable for flue gas. A 0-5000 ppm span is also available in a separate biogas-specific configuration. Choose the application and sensor configuration together, rather than selecting by measuring span alone.\u003c\/p\u003e\n\u003ch3\u003eSampling Arrangement\u003c\/h3\u003e\n\u003cp\u003eThe internal pump delivers up to 1 L\/min flow with ten adjustment settings. Sampling probes, filters and drying accessories are separate package choices. The detector's operating temperature is -20°C to 50°C. This is the instrument environment range and does not establish a temperature rating for a probe placed in a hot flue.\u003c\/p\u003e\n\u003cp\u003eThe housing measures 205 x 75 x 32 mm and weighs 300 g. A rechargeable lithium-polymer battery powers the instrument. Data logging and USB export are optional and excluded from this base configuration. Select the recording option before ordering if stored measurements are needed.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-SO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eSulfur dioxide (SO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Performance, flue-gas-specific, single-gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-200, 0-500, 0-1000, 0-2000 or 0-5000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference resistance\u003c\/td\u003e\n\u003ctd\u003eInterference-resistant sensor configuration for flue-gas SO2 measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling package\u003c\/td\u003e\n\u003ctd\u003eApplication-specific probe, filter and drying accessories are separate choices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eμmol\/mol \/ ppm \/ mg\/m³; 1 μmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eReadings and Alerts\u003c\/h3\u003e\n\u003cp\u003eThe LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available. Two alarm stages have adjustable setpoints, with sound, light and vibration outputs. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support setup.\u003c\/p\u003e\n\u003cp\u003eFollow the supplied instructions for the SO2 sensor and sampling arrangement. Gallery images show the shared housing. A case photograph does not represent a two-instrument package or establish included sampling probes.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-200 ppm","offer_id":67826857541675,"sku":"GAS-S9F4-01","price":1328.31,"currency_code":"USD","in_stock":true},{"title":"0-500 ppm","offer_id":67826857574443,"sku":"GAS-S9F4-02","price":1328.31,"currency_code":"USD","in_stock":true},{"title":"0-1000 ppm","offer_id":67826857607211,"sku":"GAS-S9F4-03","price":1362.72,"currency_code":"USD","in_stock":true},{"title":"0-2000 ppm","offer_id":67826857639979,"sku":"GAS-S9F4-04","price":1385.64,"currency_code":"USD","in_stock":true},{"title":"0-5000 ppm","offer_id":67826857672747,"sku":"GAS-S9F4-05","price":1455.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/flue-gas-sulfur-dioxide-detector-pump-angle.jpg?v=1791858962"},{"product_id":"biogas-sulfur-dioxide-detector","title":"Sulfur Dioxide Detector for Biogas - 0-5000 ppm","description":"\u003cp\u003eThis MH2000-SO2 detector is configured to measure sulfur dioxide in biogas applications over a 0-5000 ppm range. It uses an electrochemical sensor and an internal sampling pump. The High Performance sensor configuration includes interference resistance for its biogas-specific application and is supplied as a single-gas SO2 instrument.\u003c\/p\u003e\n\u003ch3\u003eSO2 Measurement in a Biogas Configuration\u003c\/h3\u003e\n\u003cp\u003eThe measured gas is sulfur dioxide. This instrument does not establish measurement of methane, carbon dioxide, hydrogen sulfide or a complete biogas composition. Select it when the measurement procedure calls for SO2 within the stated 0-5000 ppm span.\u003c\/p\u003e\n\u003cp\u003eA separate flue-gas-specific SO2 option also has a 0-5000 ppm range. The two configurations serve different applications, so the shared span does not make them interchangeable. Interference resistance identifies the selected sensor configuration and does not guarantee complete immunity to every interfering gas.\u003c\/p\u003e\n\u003ch3\u003ePortable Sampling and Readings\u003c\/h3\u003e\n\u003cp\u003eThe internal pump delivers up to 1 L\/min flow and has ten adjustment settings. The LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese operating interfaces are available. Concentration units include μmol\/mol, ppm and mg\/m³.\u003c\/p\u003e\n\u003cp\u003eThe housing measures 205 x 75 x 32 mm and weighs 300 g. It uses a 3.6 V, 2300 mAh rechargeable lithium-polymer battery, with a charging time of 4-6 hours. Filters, drying accessories and probes are separate sampling-package choices.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-SO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eSulfur dioxide (SO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Performance, biogas-specific, single-gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0-5000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference resistance\u003c\/td\u003e\n\u003ctd\u003eInterference-resistant sensor configuration for biogas SO2 measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement scope\u003c\/td\u003e\n\u003ctd\u003eSO2 only; not a multi-gas biogas analyser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eμmol\/mol \/ ppm \/ mg\/m³; 1 μmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from this base configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAlarm and Recording Choices\u003c\/h3\u003e\n\u003cp\u003eTwo alarm stages allow the setpoints to be adjusted. Sound, light and vibration provide the outputs, including an 85 dB sound alarm and blue\/red alarm lights. Temperature and pressure compensation, self-check, zero calibration and factory reset are provided for setup. Follow the supplied instructions for the biogas-specific SO2 configuration and sampling arrangement.\u003c\/p\u003e\n\u003cp\u003eData logging and PC export are optional and excluded from this base configuration. Gallery photographs illustrate the shared housing. Screen readings are illustrative, and the carrying-case image does not represent two supplied instruments or establish included PC export.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-5000 ppm","offer_id":67826857934891,"sku":"GAS-S8B5-01","price":1467.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/biogas-sulfur-dioxide-detector-pump-angle.jpg?v=1791859012"},{"product_id":"infrared-sf6-gas-detector","title":"Infrared SF6 Gas Detector - Sulfur Hexafluoride","description":"\u003cp\u003eThe MH2000-SF6 measures sulfur hexafluoride concentration with an infrared sensor and internal pump sampling. Choose a 0-1000 ppm or 0-2000 ppm version for the measuring span required by the sample and procedure. This portable High Precision configuration is a single-gas SF6 detector, with interference resistance for its selected sensor arrangement.\u003c\/p\u003e\n\u003ch3\u003eChoose the SF6 Measuring Span\u003c\/h3\u003e\n\u003cp\u003eThe 0-1000 ppm version has a lower maximum measuring span, while the 0-2000 ppm option covers a broader concentration interval. Both have 1 ppm resolution. One instrument is supplied with the range selected when ordering; it does not automatically switch between the two order versions.\u003c\/p\u003e\n\u003cp\u003eThe instrument measures SF6 concentration within that span. The configuration does not establish gas-purity analysis, dew-point measurement or a quantified leak-rate output. Interference resistance identifies the sensor configuration and does not mean complete immunity to every interfering substance.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-SF6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eSulfur hexafluoride (SF6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eInfrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Precision, interference-resistant, single-gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-1000 or 0-2000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e≤±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero shift\u003c\/td\u003e\n\u003ctd\u003e≤±1% F.S. per year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eppm \/ mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow alarm light\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh alarm light\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration functions\u003c\/td\u003e\n\u003ctd\u003eSelf-calibration and zero calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory reset\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eHigh-strength engineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSampling, Display and Instrument Setup\u003c\/h3\u003e\n\u003cp\u003eThe internal pump draws the sample at up to 1 L\/min. An LCD dot-matrix display shows concentration alongside the gas type, unit, battery level and time. The operating temperature is -20°C to 50°C, with non-condensing humidity up to 95% RH. Match the sampling arrangement to these instrument operating conditions.\u003c\/p\u003e\n\u003cp\u003eSound, light and vibration provide the alarm outputs, with adjustable setpoints. Self-calibration, zero calibration and factory reset are available for setup. Use these controls according to the supplied instructions for the selected SF6 version and the measurement procedure.\u003c\/p\u003e\n\u003ch3\u003eRecording and Package Requests\u003c\/h3\u003e\n\u003cp\u003eIf the procedure requires stored readings or PC downloads, specify the recording\/export arrangement when ordering. Sampling filters, drying accessories and probes are separate package choices for the intended measurement arrangement.\u003c\/p\u003e\n\u003cp\u003eThe 300 g housing uses a rechargeable lithium-polymer battery. Gallery photographs illustrate the shared pump-detector housing and controls. Screen readings are illustrative; a case view does not represent two supplied instruments, and a connected cable does not establish included PC export.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-1000 ppm","offer_id":67826922291243,"sku":"GAS-F8R3-01","price":2035.49,"currency_code":"USD","in_stock":true},{"title":"0-2000 ppm","offer_id":67826922324011,"sku":"GAS-F8R3-02","price":2101.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/infrared-sf6-gas-detector-pump-front.jpg?v=1791861530"},{"product_id":"electrochemical-ethylene-oxide-gas-detector","title":"Ethylene Oxide Gas Detector - Electrochemical Pump Sampling","description":"\u003cp\u003eChoose an electrochemical ethylene oxide detector by the concentration span required for your measurement. The MH2000-EO uses internal pump sampling and is available in six Standard versions, from 0-10 ppm through 0-1000 ppm. Ethylene oxide may also be identified as EO or EtO.\u003c\/p\u003e\n\u003ch3\u003eSix Standard Range Options\u003c\/h3\u003e\n\u003cp\u003eThe 0-10, 0-50 and 0-100 ppm versions cover lower maximum concentrations. For a wider measuring interval, select 0-200, 0-500 or 0-1000 ppm. Every option starts at zero and measures the same gas using the electrochemical configuration.\u003c\/p\u003e\n\u003cp\u003eThe range selected when ordering is the measuring span of that instrument. A six-option menu does not mean that one detector switches between all six spans. Match the chosen upper limit to the expected concentration and the requirements of the measurement procedure.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-EO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eEthylene oxide (EO \/ EtO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-10 ppm; 0-50 ppm; 0-100 ppm; 0-200 ppm; 0-500 ppm; 0-1000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eppm \/ mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow alarm light\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh alarm light\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration functions\u003c\/td\u003e\n\u003ctd\u003eSelf-calibration and zero calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory reset\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eHigh-strength engineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eReadings and Instrument Controls\u003c\/h3\u003e\n\u003cp\u003eThe LCD presents the concentration, gas identification, selected unit, battery level and time together. Concentration units can be changed between ppm and mg\/m³. Sound, light and vibration provide alarm outputs, and the alarm setpoints are adjustable.\u003c\/p\u003e\n\u003cp\u003eSelf-calibration and zero calibration are available for instrument setup, along with a factory reset. Follow the supplied instructions for the selected measuring version when using these controls.\u003c\/p\u003e\n\u003ch3\u003eSampling and Order Details\u003c\/h3\u003e\n\u003cp\u003eThe operating limits in the table apply to the instrument. Select the sampling arrangement to keep the measurement within those temperature and non-condensing humidity conditions. If stored readings or PC downloads are required, specify the recording and export arrangement when ordering. Filters, drying accessories and probes are separate package choices.\u003c\/p\u003e\n\u003cp\u003eThis link covers the Standard electrochemical configuration. The PID PPM configuration is offered as a separate product. Gallery photographs show the shared pump-detector housing; displayed readings are illustrative, and the carrying-case view does not represent a two-instrument package.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-10 ppm","offer_id":67827011026987,"sku":"GAS-E6T8-01","price":698.76,"currency_code":"USD","in_stock":true},{"title":"0-50 ppm","offer_id":67827011059755,"sku":"GAS-E6T8-02","price":698.76,"currency_code":"USD","in_stock":true},{"title":"0-100 ppm","offer_id":67827011092523,"sku":"GAS-E6T8-03","price":706.41,"currency_code":"USD","in_stock":true},{"title":"0-200 ppm","offer_id":67827011125291,"sku":"GAS-E6T8-04","price":953.86,"currency_code":"USD","in_stock":true},{"title":"0-500 ppm","offer_id":67827011158059,"sku":"GAS-E6T8-05","price":984.7,"currency_code":"USD","in_stock":true},{"title":"0-1000 ppm","offer_id":67827011190827,"sku":"GAS-E6T8-06","price":984.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/electrochemical-ethylene-oxide-gas-detector-pump-front.jpg?v=1791864224"},{"product_id":"pid-ethylene-oxide-gas-detector","title":"PID Ethylene Oxide Gas Detector - High Precision PPM","description":"\u003cp\u003eThe PID ethylene oxide gas detector is the MH2000-EO High Precision PPM configuration, offered with five measuring spans. Select 0-100, 0-200, 0-1000, 0-2000 or 0-3000 ppm for the concentration interval required by your procedure. This product uses a photoionization sensor rather than the Standard electrochemical configuration.\u003c\/p\u003e\n\u003ch3\u003ePID Configuration and Range Selection\u003c\/h3\u003e\n\u003cp\u003eAll five options use the PPM sensor configuration. The 0-100 and 0-200 ppm versions have lower upper limits; 0-1000, 0-2000 and 0-3000 ppm cover broader intervals. Each starts at zero. The order selection identifies one measuring version, not five ranges that can be exchanged during operation.\u003c\/p\u003e\n\u003cp\u003eSensor configuration and upper measuring limit are separate purchase decisions. A 0-100 or 0-200 ppm PID version and an electrochemical version with the same span are different configurations. Use the PID label when specifying this product, together with the selected range and ethylene oxide gas identity.\u003c\/p\u003e\n\u003ch3\u003ePump Sampling and Controls\u003c\/h3\u003e\n\u003cp\u003eInternal pump sampling brings the sample to the instrument. The LCD shows the gas concentration together with the gas type, unit, battery level and time. Adjustable alarm points and sound, light and vibration outputs support the instrument's concentration alarm functions.\u003c\/p\u003e\n\u003cp\u003eSelf-calibration, zero calibration and factory reset are available. Use the supplied instructions for the selected PID version and the intended measurement procedure when setting up the instrument.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-EO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eEthylene oxide (EO \/ EtO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003ePhotoionization (PID)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Precision, PPM sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-100 ppm; 0-200 ppm; 0-1000 ppm; 0-2000 ppm; 0-3000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eppm \/ mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow alarm light\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh alarm light\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration functions\u003c\/td\u003e\n\u003ctd\u003eSelf-calibration and zero calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory reset\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eHigh-strength engineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecify the Measurement Arrangement\u003c\/h3\u003e\n\u003cp\u003eChoose the sampling arrangement for the operating conditions listed above. Recording, PC export, filters, drying accessories and probes should be specified as order requirements when needed. Gallery views illustrate the shared housing and controls; screen readings do not identify the supplied PID sensor or range, and a case photograph does not establish a two-instrument bundle.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-100 ppm","offer_id":67827013976107,"sku":"GAS-P4E7-01","price":2535.23,"currency_code":"USD","in_stock":true},{"title":"0-200 ppm","offer_id":67827014008875,"sku":"GAS-P4E7-02","price":2505.23,"currency_code":"USD","in_stock":true},{"title":"0-1000 ppm","offer_id":67827014041643,"sku":"GAS-P4E7-03","price":2591.24,"currency_code":"USD","in_stock":true},{"title":"0-2000 ppm","offer_id":67827014074411,"sku":"GAS-P4E7-04","price":2591.24,"currency_code":"USD","in_stock":true},{"title":"0-3000 ppm","offer_id":67827014107179,"sku":"GAS-P4E7-05","price":2636.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/pid-ethylene-oxide-gas-detector-pump-front.jpg?v=1791864309"},{"product_id":"pump-phosphine-gas-detector","title":"Pump Phosphine Gas Detector - Standard \u0026 High Performance","description":"\u003cp\u003eThe MH2000-PH3 is an electrochemical phosphine gas detector with internal pump sampling. Select a Standard version from eight measuring spans, or a High Performance version in 0-2000 or 0-3000 ppm. The instrument measures PH3 concentration and presents the reading on an LCD dot-matrix display.\u003c\/p\u003e\n\u003ch3\u003eChoose the Performance and Measuring Span\u003c\/h3\u003e\n\u003cp\u003eStandard options are 0-5, 0-20, 0-50, 0-100, 0-500, 0-1000, 0-2000 and 0-3000 ppm. High Performance options are available only in 0-2000 and 0-3000 ppm. Choose both the performance grade and range when ordering; a higher upper measuring limit does not by itself identify a different performance grade.\u003c\/p\u003e\n\u003cp\u003eThe 2000 and 3000 ppm versions in either grade are single-gas configurations. This product measures phosphine only. Each ordered instrument has its selected span; the range menu does not represent interchangeable measuring ranges on one unit.\u003c\/p\u003e\n\u003ch3\u003eSampling and Operator Controls\u003c\/h3\u003e\n\u003cp\u003eTen suction levels provide pump adjustment, with flow up to 1 L\/min. The interface supports English and Chinese. Concentration units can be switched between µmol\/mol, ppm and mg\/m³; 1 µmol\/mol equals 1 ppm.\u003c\/p\u003e\n\u003cp\u003eTwo-stage sound and light alarms use adjustable setpoints, with vibration also available as an alarm output. Self-check, zero calibration and factory reset support setup. Temperature and pressure compensation are included as instrument functions. Use the supplied instructions for the selected PH3 configuration and measurement procedure.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-PH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003ePhosphine (PH3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance options\u003c\/td\u003e\n\u003ctd\u003eStandard \/ High Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard measuring spans\u003c\/td\u003e\n\u003ctd\u003e0-5 ppm; 0-20 ppm; 0-50 ppm; 0-100 ppm; 0-500 ppm; 0-1000 ppm; 0-2000 ppm; 0-3000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Performance measuring spans\u003c\/td\u003e\n\u003ctd\u003e0-2000 ppm; 0-3000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas configuration\u003c\/td\u003e\n\u003ctd\u003eSingle-gas PH3; 2000\/3000 ppm versions are single-gas only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eµmol\/mol, ppm, mg\/m³; 1 µmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish \/ Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo-stage sound and light alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue low alarm \/ red high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup functions\u003c\/td\u003e\n\u003ctd\u003eSelf-check and zero calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory reset\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensation functions\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eHigh-strength engineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording\u003c\/td\u003e\n\u003ctd\u003eOptional; more than 100,000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording interval\u003c\/td\u003e\n\u003ctd\u003e5-3600 seconds, adjustable with optional recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC transfer\u003c\/td\u003e\n\u003ctd\u003eUSB download and printing with optional data function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecording Options and Package\u003c\/h3\u003e\n\u003cp\u003eData recording and USB transfer are optional functions. With recording fitted, capacity exceeds 100,000 records and the interval can be adjusted from 5 to 3600 seconds. Specify recording and PC download requirements when selecting the order configuration.\u003c\/p\u003e\n\u003cp\u003eThe standard package contains the detector, carrying case, charging\/data cable and instruction manual. A supplied cable does not include the optional recording function by itself. Gallery photographs illustrate the shared pump-detector housing and controls; screen readings are illustrative, and the case view does not represent two supplied instruments.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"Standard \/ 0-5 ppm","offer_id":67827151765547,"sku":"GAS-P6H9-01","price":687.1,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-20 ppm","offer_id":67827151798315,"sku":"GAS-P6H9-02","price":687.1,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-50 ppm","offer_id":67827151831083,"sku":"GAS-P6H9-03","price":698.84,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-100 ppm","offer_id":67827151863851,"sku":"GAS-P6H9-04","price":698.84,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-500 ppm","offer_id":67827151896619,"sku":"GAS-P6H9-05","price":976.28,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-1000 ppm","offer_id":67827151929387,"sku":"GAS-P6H9-06","price":976.28,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-2000 ppm","offer_id":67827151962155,"sku":"GAS-P6H9-07","price":1180.11,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-3000 ppm","offer_id":67827151994923,"sku":"GAS-P6H9-08","price":1217.74,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-2000 ppm","offer_id":67827152027691,"sku":"GAS-P6H9-09","price":1312.14,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-3000 ppm","offer_id":67827152060459,"sku":"GAS-P6H9-10","price":1354.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/pump-phosphine-gas-detector-pump-angle.jpg?v=1791871640"},{"product_id":"hydrogen-chloride-gas-detector-pump","title":"Hydrogen Chloride Detector with Adjustable Pump Sampling","description":"\u003cp\u003eMeasure hydrogen chloride concentration with the MH2000-HCL electrochemical detector and its adjustable internal sampling pump. This portable HCl detector is available in Standard, High Precision and High Performance configurations, with the measuring span selected for the order.\u003c\/p\u003e\n\u003ch3\u003eHCl Configurations and Measuring Spans\u003c\/h3\u003e\n\u003cp\u003eStandard and High Precision versions each offer 0-10, 0-20, 0-50 and 0-100 ppm. They share the same available spans but are separate performance configurations. Select the performance grade as well as the range to identify the required version.\u003c\/p\u003e\n\u003cp\u003eHigh Performance versions cover 0-500, 0-1000 or 0-2000 ppm and are single-gas instruments. All options on this page measure hydrogen chloride only. The menu describes eleven order combinations, with one selected configuration supplied per instrument.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-HCL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eHydrogen chloride (HCl)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance options\u003c\/td\u003e\n\u003ctd\u003eStandard \/ High Precision \/ High Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard measuring spans\u003c\/td\u003e\n\u003ctd\u003e0-10 ppm; 0-20 ppm; 0-50 ppm; 0-100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Precision measuring spans\u003c\/td\u003e\n\u003ctd\u003e0-10 ppm; 0-20 ppm; 0-50 ppm; 0-100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Performance measuring spans\u003c\/td\u003e\n\u003ctd\u003e0-500 ppm; 0-1000 ppm; 0-2000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas configuration\u003c\/td\u003e\n\u003ctd\u003eSingle-gas HCl; High Performance versions are single-gas only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eµmol\/mol, ppm, mg\/m³; 1 µmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish \/ Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo-stage sound and light alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue low alarm \/ red high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup functions\u003c\/td\u003e\n\u003ctd\u003eSelf-check and zero calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory reset\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensation functions\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eHigh-strength engineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording\u003c\/td\u003e\n\u003ctd\u003eOptional; more than 100,000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording interval\u003c\/td\u003e\n\u003ctd\u003e5-3600 seconds, adjustable with optional recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC transfer\u003c\/td\u003e\n\u003ctd\u003eUSB download and printing with optional data function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSampling Adjustment and Display\u003c\/h3\u003e\n\u003cp\u003eThe internal pump provides ten suction levels and flow up to 1 L\/min. An LCD dot-matrix display presents the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available, and the concentration display can switch between µmol\/mol, ppm and mg\/m³.\u003c\/p\u003e\n\u003cp\u003eTwo-stage sound and light alarms have adjustable setpoints, with vibration also available as an alarm output. Self-check and zero calibration support instrument setup, alongside factory reset and temperature and pressure compensation functions. Follow the supplied instructions for the chosen HCl configuration when using these controls.\u003c\/p\u003e\n\u003ch3\u003eRecording and Package Choices\u003c\/h3\u003e\n\u003cp\u003eOptional recording stores more than 100,000 readings, with an adjustable interval of 5 to 3600 seconds. USB download and printing are optional data functions. Specify these requirements when ordering so the selected package matches the intended recordkeeping procedure.\u003c\/p\u003e\n\u003cp\u003eThe standard package contains the detector, carrying case, charging\/data cable and instruction manual. The cable alone does not provide the optional recording function. Gallery images illustrate the shared pump-detector housing; screen readings are illustrative and the case view does not represent two supplied detectors.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"Standard \/ 0-10 ppm","offer_id":67828453769259,"sku":"GAS-H4C8-01","price":957.86,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-20 ppm","offer_id":67828453802027,"sku":"GAS-H4C8-02","price":957.86,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-50 ppm","offer_id":67828453834795,"sku":"GAS-H4C8-03","price":981.11,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-100 ppm","offer_id":67828453867563,"sku":"GAS-H4C8-04","price":993.26,"currency_code":"USD","in_stock":true},{"title":"High Precision \/ 0-10 ppm","offer_id":67828453900331,"sku":"GAS-H4C8-05","price":1338.58,"currency_code":"USD","in_stock":true},{"title":"High Precision \/ 0-20 ppm","offer_id":67828453933099,"sku":"GAS-H4C8-06","price":957.86,"currency_code":"USD","in_stock":true},{"title":"High Precision \/ 0-50 ppm","offer_id":67828453965867,"sku":"GAS-H4C8-07","price":1371.36,"currency_code":"USD","in_stock":true},{"title":"High Precision \/ 0-100 ppm","offer_id":67828453998635,"sku":"GAS-H4C8-08","price":1377.47,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-500 ppm","offer_id":67828454031403,"sku":"GAS-H4C8-09","price":1621.6,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-1000 ppm","offer_id":67828454064171,"sku":"GAS-H4C8-10","price":1652.89,"currency_code":"USD","in_stock":true},{"title":"High Performance \/ 0-2000 ppm","offer_id":67828454096939,"sku":"GAS-H4C8-11","price":1652.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/hydrogen-chloride-gas-detector-pump-pump-angle.jpg?v=1791874221"},{"product_id":"hydrogen-cyanide-gas-detector","title":"Hydrogen Cyanide Gas Detector - 10\/50\/100 ppm","description":"\u003cp\u003eThe MH2000-HCN Standard detector measures hydrogen cyanide concentration with an electrochemical sensor and internal pump sampling. Choose a 0-10, 0-50 or 0-100 ppm version for the concentration interval required by your measurement procedure.\u003c\/p\u003e\n\u003ch3\u003eThree Standard HCN Range Options\u003c\/h3\u003e\n\u003cp\u003eEach option starts at zero and has a different upper measuring limit. The selected range identifies the version supplied with the order. A three-option menu represents three instrument configurations; one detector is supplied with its selected span.\u003c\/p\u003e\n\u003cp\u003eThis link covers the Standard electrochemical configuration. A separate HCN configuration is available for smelting applications when the measurement specification calls for that sensor arrangement. Identify the gas, performance configuration and range together when selecting the instrument.\u003c\/p\u003e\n\u003ch3\u003eDisplay and Sampling Controls\u003c\/h3\u003e\n\u003cp\u003eThe internal pump has ten adjustable suction levels, with flow up to 1 L\/min. The LCD displays concentration alongside the gas type, unit, battery level and time. English and Chinese interfaces are available. Units can be switched between µmol\/mol, ppm and mg\/m³, with 1 µmol\/mol equal to 1 ppm.\u003c\/p\u003e\n\u003cp\u003eAdjustable setpoints control the two-stage sound and light alarms, and vibration is also available as an alarm output. Instrument setup includes self-check, zero calibration, factory reset, and temperature and pressure compensation functions. Use the supplied instructions for the selected HCN version.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-HCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eHydrogen cyanide (HCN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-10 ppm; 0-50 ppm; 0-100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas configuration\u003c\/td\u003e\n\u003ctd\u003eSingle-gas HCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eµmol\/mol, ppm, mg\/m³; 1 µmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish \/ Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo-stage sound and light alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue low alarm \/ red high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup functions\u003c\/td\u003e\n\u003ctd\u003eSelf-check and zero calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory reset\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensation functions\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eHigh-strength engineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording\u003c\/td\u003e\n\u003ctd\u003eOptional; more than 100,000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording interval\u003c\/td\u003e\n\u003ctd\u003e5-3600 seconds, adjustable with optional recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC transfer\u003c\/td\u003e\n\u003ctd\u003eUSB download and printing with optional data function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecording and Supplied Package\u003c\/h3\u003e\n\u003cp\u003eData recording and USB download or printing are optional functions. The recording option stores more than 100,000 readings, with intervals adjustable from 5 to 3600 seconds. Specify these functions when the procedure requires recorded measurements or PC transfer.\u003c\/p\u003e\n\u003cp\u003eThe standard package contains the detector, carrying case, charging\/data cable and instruction manual. Gallery photographs illustrate the shared pump housing and controls. Screen readings are illustrative. The order contains one detector, and recording is supplied only when selected as an optional function.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-10 ppm","offer_id":67828676427819,"sku":"GAS-H6N8-01","price":934.36,"currency_code":"USD","in_stock":true},{"title":"0-50 ppm","offer_id":67828676460587,"sku":"GAS-H6N8-02","price":965.96,"currency_code":"USD","in_stock":true},{"title":"0-100 ppm","offer_id":67828676493355,"sku":"GAS-H6N8-03","price":965.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/hydrogen-cyanide-gas-detector-front-view.jpg?v=1791880798"},{"product_id":"hcn-gas-detector-smelting","title":"HCN Gas Detector for Smelting - High Precision","description":"\u003cp\u003eFor smelting applications requiring an interference-resistant HCN sensor configuration, select this MH2000-HCN High Precision hydrogen cyanide detector. It combines electrochemical sensing with internal pump sampling and is offered in 0-10, 0-50 or 0-100 ppm versions.\u003c\/p\u003e\n\u003ch3\u003eSmelting Configuration and Range Selection\u003c\/h3\u003e\n\u003cp\u003eThis is the High Precision configuration for smelting, with interference resistance as a sensor feature. Select it by application and sensor configuration, then choose the upper measuring limit needed by the measurement procedure.\u003c\/p\u003e\n\u003cp\u003eAll three ranges begin at zero. The chosen span identifies one order version. Although the Standard HCN product offers the same three spans, this link identifies the dedicated smelting configuration. Include that configuration name when specifying the instrument for purchase.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-HCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eHydrogen cyanide (HCN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Precision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-10 ppm; 0-50 ppm; 0-100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas configuration\u003c\/td\u003e\n\u003ctd\u003eSingle-gas HCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended application\u003c\/td\u003e\n\u003ctd\u003eSmelting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor feature\u003c\/td\u003e\n\u003ctd\u003eInterference resistance for this HCN sensor configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eµmol\/mol, ppm, mg\/m³; 1 µmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish \/ Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo-stage sound and light alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue low alarm \/ red high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup functions\u003c\/td\u003e\n\u003ctd\u003eSelf-check and zero calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory reset\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensation functions\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eHigh-strength engineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording\u003c\/td\u003e\n\u003ctd\u003eOptional; more than 100,000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording interval\u003c\/td\u003e\n\u003ctd\u003e5-3600 seconds, adjustable with optional recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC transfer\u003c\/td\u003e\n\u003ctd\u003eUSB download and printing with optional data function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSampling Arrangement and Instrument Setup\u003c\/h3\u003e\n\u003cp\u003eTen suction levels adjust the internal pump, with flow up to 1 L\/min. The instrument operating limits are -20°C to 50°C and 0-95% RH under non-condensing conditions. Plan the sampling arrangement around those instrument operating conditions.\u003c\/p\u003e\n\u003cp\u003eAn LCD dot-matrix display presents gas concentration, gas identity, unit, battery level and time. English and Chinese interfaces are supported, with selectable concentration units. Two-stage sound and light alarms use adjustable setpoints, and vibration is also available as an alarm output.\u003c\/p\u003e\n\u003cp\u003eSelf-check, zero calibration, factory reset and temperature and pressure compensation are available for setup. Follow the supplied instructions for the selected HCN configuration and the intended measurement procedure when using these controls.\u003c\/p\u003e\n\u003ch3\u003eRecording and Package\u003c\/h3\u003e\n\u003cp\u003eOptional recording supports more than 100,000 readings and an adjustable 5-3600 second interval. Specify optional USB download and printing requirements when ordering. The standard package includes the instrument, carrying case, charging\/data cable and instruction manual.\u003c\/p\u003e\n\u003cp\u003eGallery views show the shared pump-detector housing; displayed readings are illustrative. The package contains one detector; recording is supplied only when selected as an optional function.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-10 ppm","offer_id":67828676886571,"sku":"GAS-S8N3-01","price":2276.09,"currency_code":"USD","in_stock":true},{"title":"0-50 ppm","offer_id":67828676919339,"sku":"GAS-S8N3-02","price":2276.09,"currency_code":"USD","in_stock":true},{"title":"0-100 ppm","offer_id":67828676952107,"sku":"GAS-S8N3-03","price":2321.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/hcn-gas-detector-smelting-front-view.jpg?v=1791880880"},{"product_id":"pid-voc-gas-detector","title":"PID VOC Gas Detector - Portable Pump Monitor","description":"\u003cp\u003eThe MH2000-VOC is a portable photoionization detector for volatile organic compound concentration readings. Its High Precision PPM sensor configuration is available in five measuring spans, with an internal pump drawing the sample to the instrument. Use it for VOC concentration checks in a painting workshop, selecting the measuring span for the sampling task.\u003c\/p\u003e\n\u003ch3\u003eSelect the PPM Measuring Span\u003c\/h3\u003e\n\u003cp\u003eChoose 0-100, 0-200, 0-1000, 0-2000 or 0-5000 ppm. Each option begins at zero, and the upper limit identifies the measuring version supplied with the order. Match the chosen interval to the concentration expected by the measurement procedure.\u003c\/p\u003e\n\u003cp\u003eAll five order options use the PID PPM configuration. The selection menu identifies one instrument version at a time. Include the VOC configuration and selected span together when specifying the detector for purchase.\u003c\/p\u003e\n\u003ch3\u003eSampling, Display and Alarm Controls\u003c\/h3\u003e\n\u003cp\u003eThe internal pump has ten suction levels, with flow up to 1 L\/min. The LCD shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are supported, and concentration display units include µmol\/mol, ppm and mg\/m³.\u003c\/p\u003e\n\u003cp\u003eTwo-stage sound and light alarms use adjustable setpoints. Self-check and zero calibration support setup, along with factory reset and temperature and pressure compensation functions. Follow the supplied instructions for the chosen VOC configuration when setting up these controls.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-VOC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eVolatile organic compounds (VOC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003ePhotoionization (PID)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHigh Precision, PPM sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range options\u003c\/td\u003e\n\u003ctd\u003e0-100 ppm; 0-200 ppm; 0-1000 ppm; 0-2000 ppm; 0-5000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication example\u003c\/td\u003e\n\u003ctd\u003eVOC concentration checks in painting workshops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 suction levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eµmol\/mol, ppm, mg\/m³; 1 µmol\/mol = 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface languages\u003c\/td\u003e\n\u003ctd\u003eEnglish \/ Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound and light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo-stage sound and light alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue low alarm \/ red high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup functions\u003c\/td\u003e\n\u003ctd\u003eSelf-check and zero calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory reset\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensation functions\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eHigh-strength engineering plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording\u003c\/td\u003e\n\u003ctd\u003eOptional; more than 100,000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording interval\u003c\/td\u003e\n\u003ctd\u003e5-3600 seconds, adjustable with optional recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC transfer\u003c\/td\u003e\n\u003ctd\u003eUSB download and printing with optional data function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecording Options and Package\u003c\/h3\u003e\n\u003cp\u003eData recording and USB download or printing are optional. With recording fitted, storage exceeds 100,000 readings and the interval can be set from 5 to 3600 seconds. Specify these functions when the procedure requires stored measurements or PC transfer.\u003c\/p\u003e\n\u003cp\u003eThe standard package contains one detector, a carrying case, charging\/data cable and instruction manual. Gallery photographs illustrate the shared pump-detector housing and controls; screen readings are illustrative. Optional recording is supplied when selected as an order requirement.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-100 ppm","offer_id":67828711129131,"sku":"GAS-V7P4-01","price":2566.19,"currency_code":"USD","in_stock":true},{"title":"0-200 ppm","offer_id":67828711161899,"sku":"GAS-V7P4-02","price":2566.19,"currency_code":"USD","in_stock":true},{"title":"0-1000 ppm","offer_id":67828711194667,"sku":"GAS-V7P4-03","price":2613.68,"currency_code":"USD","in_stock":true},{"title":"0-2000 ppm","offer_id":67828711227435,"sku":"GAS-V7P4-04","price":2613.68,"currency_code":"USD","in_stock":true},{"title":"0-5000 ppm","offer_id":67828711260203,"sku":"GAS-V7P4-05","price":2685.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/pid-voc-gas-detector-angled-view.jpg?v=1791883246"},{"product_id":"car-paint-thickness-gauge-ls239","title":"Car Paint Thickness Gauge with Vehicle Records - LS239","description":"\u003cp\u003eThe Linshang LS239 car paint thickness gauge measures coatings on steel and aluminum panels from 0 to 5000 µm. It combines an integrated ruby-tipped probe with vehicle records and Bluetooth reporting for used-car inspection and bodywork assessment.\u003c\/p\u003e\n\u003ch3\u003eChoose a simple check or a vehicle record\u003c\/h3\u003e\n\u003cp\u003eSimple mode supports individual readings and stores up to 60 measurements. Expert mode organizes results into 19 component groups, with six measurement points per group and capacity for up to 999 vehicles. This keeps readings associated with their inspection locations when comparing panels around a car.\u003c\/p\u003e\n\u003cp\u003eBluetooth connects the instrument to the mobile app for recording measurements and generating reports. Adjustable alarm limits and a three-color backlight help distinguish readings against the limits selected for the inspection. While connected to the app or WeChat Mini Program, the instrument uses simple mode with alarms disabled; disconnecting restores the selected measurement mode.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/car-paint-thickness-gauge-ls239-vehicle-records.jpg?v=1793696650\" alt=\"LS239 expert measurement mode illustrating grouped vehicle inspection records\" width=\"990\" height=\"788\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS239 expert measurement mode illustrating grouped vehicle inspection records\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRecognize the substrate before comparing paint\u003c\/h3\u003e\n\u003cp\u003eThe gauge automatically distinguishes steel and aluminum and can indicate galvanized iron, ferrous putty and non-metal substrates. Thickness measurement applies to suitable metal substrates; a non-metal indication does not provide a paint-thickness reading on plastic or carbon fiber.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/car-paint-thickness-gauge-ls239-bluetooth-app.jpg?v=1793696663\" alt=\"LS239 gauge used beside a phone displaying the measurement app\" width=\"2000\" height=\"1333\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS239 gauge used beside a phone displaying the measurement app\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLS239\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd\u003e0–5000 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement principles\u003c\/th\u003e\n\u003ctd\u003eHall effect for ferrous substrates; eddy current for aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy, 0–3000 µm\u003c\/th\u003e\n\u003ctd\u003e±(3%H + 2 µm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy, 3000–5000 µm\u003c\/th\u003e\n\u003ctd\u003e±(5%H + 2 µm); H is the standard value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSelectable resolution\u003c\/th\u003e\n\u003ctd\u003e0.1, 1 or 10 µm; displayed resolution varies with range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpecified measuring interval\u003c\/th\u003e\n\u003ctd\u003e0.5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum measuring area\u003c\/th\u003e\n\u003ctd\u003e25 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum substrate thickness\u003c\/th\u003e\n\u003ctd\u003eSteel: 0.2 mm; aluminum: 0.05 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003e3.7 V, 1200 mAh rechargeable lithium battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay and data transfer\u003c\/th\u003e\n\u003ctd\u003e192 x 64 LCD; Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument dimensions\u003c\/th\u003e\n\u003ctd\u003e108 x 70 x 31 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument weight\u003c\/th\u003e\n\u003ctd\u003e88.8 g including battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBefore a vehicle inspection\u003c\/h3\u003e\n\u003cp\u003ePerform the appropriate zero adjustment when first using the gauge or when the substrate or measurement conditions change. Compare readings across suitable panels together with the substrate indications; a thickness reading alone does not establish a vehicle's repair history.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68113254416427,"sku":"THK-Q7M4-01","price":201.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/car-paint-thickness-gauge-ls239-front-square-main-1200-v3.jpg?v=1793779723"},{"product_id":"dry-film-thickness-gauge-ls220h","title":"Dry Film Thickness Gauge LS220H - 0-5000 µm, Fe\/NFe","description":"\u003cp\u003eThe Linshang LS220H dry film thickness gauge measures non-magnetic coatings on steel or iron and non-conductive coatings on non-ferrous metals such as aluminum and copper. Its integrated Fe\/NFe probe covers 0–5000 µm, making it suitable for checking paint, powder coatings and anodized layers on compatible metal substrates.\u003c\/p\u003e\n\u003ch3\u003eMatch the measurement to the substrate\u003c\/h3\u003e\n\u003cp\u003eSelect Fe mode for a ferrous base, NFe mode for a non-ferrous base, or automatic Fe\/NFe identification when working across both. The probe uses Hall effect measurement for ferrous substrates and eddy current measurement for non-ferrous substrates.\u003c\/p\u003e\n\u003cp\u003eThe ruby-tipped probe is built into the gauge for one-hand use. Take individual point measurements with the probe perpendicular to the surface; lift the gauge between readings rather than sliding the probe across the coating.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coating-thickness-gauge-ls220h-ruby-probe.jpg?v=1793701263\" alt=\"Ruby-tipped integrated probe on the LS220H thickness gauge\" width=\"2000\" height=\"1333\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eRuby-tipped integrated probe on the LS220H thickness gauge\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRange, accuracy and measurement limits\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd\u003e0–5000 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy; H is the reference thickness\u003c\/th\u003e\n\u003ctd\u003e0–3000 µm: ≤±(3%H + 2 µm); 3000–5000 µm: ≤±(5%H + 2 µm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.1 µm at 0–99.9 µm; 1 µm at 100–999 µm; 0.01 mm at 1.00–5.00 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring interval\u003c\/th\u003e\n\u003ctd\u003e0.5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum measuring area\u003c\/th\u003e\n\u003ctd\u003e25 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum substrate thickness\u003c\/th\u003e\n\u003ctd\u003eFe: 0.2 mm; NFe: 0.05 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum curvature radius\u003c\/th\u003e\n\u003ctd\u003eConvex: 5 mm; concave: 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnits\u003c\/th\u003e\n\u003ctd\u003eµm \/ mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 48 dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eTwo 1.5 V AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions and instrument weight\u003c\/th\u003e\n\u003ctd\u003e101 x 62 x 28 mm; 79 g including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coating-thickness-gauge-ls220h-substrate-modes.jpg?v=1793701272\" alt=\"LS220H display illustrating Fe, NFe and automatic substrate modes\" width=\"990\" height=\"1174\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS220H display illustrating Fe, NFe and automatic substrate modes\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eZero adjustment and recent readings\u003c\/h3\u003e\n\u003cp\u003ePerform zero adjustment on a suitable uncoated substrate when first using the gauge, after replacing batteries, or when the material or ambient conditions change. The gauge retains the nine most recent readings, with the oldest value replaced as new readings are taken.\u003c\/p\u003e\n\u003cp\u003eCheck that the workpiece meets the minimum area, thickness and curvature requirements. The coating\/substrate combination matters: this gauge does not measure every coating on every metal.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68113896734763,"sku":"THK-R8T6-01","price":244.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coating-thickness-gauge-ls220h-front-square-main-1200-v3.jpg?v=1793779641"},{"product_id":"flat-plate-coating-thickness-gauge-ls226","title":"Flat-Plate Coating Thickness Gauge LS226 - Dual Display","description":"\u003cp\u003eThe Linshang LS226 coating thickness gauge is designed for measurements on flat coated metal plates. Its integrated probe uses the instrument's own weight to provide consistent positioning, while front and top displays make readings visible from different viewing positions.\u003c\/p\u003e\n\u003ch3\u003eFlat-workpiece checks with Fe\/NFe detection\u003c\/h3\u003e\n\u003cp\u003eThe gauge measures non-magnetic coatings on ferrous metal and non-conductive coatings on non-ferrous metal. Automatic substrate identification switches between Fe and NFe; fixed-substrate modes are also available.\u003c\/p\u003e\n\u003cp\u003eTypical measurement tasks include paint on metal, anodized layers and coatings on thin sheet substrates. The minimum measuring area is 15 mm in diameter. Check that the substrate is at least 0.2 mm thick for Fe or 0.05 mm for NFe before comparing results.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coating-thickness-gauge-ls226-dual-display.jpg?v=1793701362\" alt=\"Front and top displays on the LS226 coating thickness gauge\" width=\"990\" height=\"628\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eFront and top displays on the LS226 coating thickness gauge\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eCalibration, QC and measurement records\u003c\/h3\u003e\n\u003cp\u003eZero adjustment and one- to five-point calibration let the measurement setup be matched to the workpiece. Normal and QC modes are available for routine readings and checks against thickness limits.\u003c\/p\u003e\n\u003cp\u003eSingle measurement mode is recommended for precision measurements. Continuous mode takes readings about every 0.1 s, but does not store measurement data or allow access to the history interface while it is active. In single measurement use, the instrument stores the nine most recent readings.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coating-thickness-gauge-ls226-qc-mode.jpg?v=1793701370\" alt=\"LS226 normal and QC mode displays during coating checks\" width=\"990\" height=\"646\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS226 normal and QC mode displays during coating checks\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eLS226 specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntegrated probe tip\u003c\/th\u003e\n\u003ctd\u003eCemented carbide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePrinciples\u003c\/th\u003e\n\u003ctd\u003eFe: magnetic induction; NFe: eddy current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd\u003e0–2000 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy; H is the reference thickness\u003c\/th\u003e\n\u003ctd\u003e0–1000 µm: ≤±(2%H + 1 µm); 1000–2000 µm: ≤±3%H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.1 µm at 0–99.9 µm; 1 µm at 100–2000 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSingle measuring interval\u003c\/th\u003e\n\u003ctd\u003e0.3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnits\u003c\/th\u003e\n\u003ctd\u003eµm \/ mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 48 dot-matrix LCD; front and top displays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eTwo 1.5 V AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions and instrument weight\u003c\/th\u003e\n\u003ctd\u003e90 x 65 x 28 mm; 123 g including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eBluetooth connects the gauge to the UT and HL mobile app. The app supports Android and does not support iOS. Keep the probe steady during individual measurements and perform zero adjustment on an appropriate uncoated substrate when material or conditions change.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68113930682411,"sku":"THK-V4N8-01","price":446.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coating-thickness-gauge-ls226-front-square-main-1200-v3.jpg?v=1793779673"},{"product_id":"multi-probe-coating-thickness-gauge-ls227","title":"Multi-Probe Coating Thickness Gauge LS227 - Probe Kits","description":"\u003cp\u003eBuild a coating-thickness inspection setup around the Linshang LS227 touchscreen main unit and a probe suited to the workpiece. Each configuration on this page pairs one LS227 main unit with the single probe named in the selected option. Additional probes and test stands are separate options.\u003c\/p\u003e\n\u003ch3\u003eChoose the probe for the coating and geometry\u003c\/h3\u003e\n\u003cp\u003eFerrous probes measure non-magnetic coatings on ferromagnetic metal. Non-ferrous probes measure non-conductive coatings on non-ferromagnetic metal. Dual-substrate probes support both combinations. The connected probe determines the measuring range, access geometry and accuracy.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eProbe option\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRange\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSubstrate and shape\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eF600-X0\u003c\/td\u003e\n\u003ctd\u003e0–600 µm\u003c\/td\u003e\n\u003ctd\u003eFerrous; Straight, small tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF1600-X0\u003c\/td\u003e\n\u003ctd\u003e0–1600 µm\u003c\/td\u003e\n\u003ctd\u003eNon-ferrous; Straight, small tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFNF2000-X0\u003c\/td\u003e\n\u003ctd\u003e0–2000 µm\u003c\/td\u003e\n\u003ctd\u003eFerrous and non-ferrous; Straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFNF5000-X0\u003c\/td\u003e\n\u003ctd\u003e0–5000 µm\u003c\/td\u003e\n\u003ctd\u003eFerrous and non-ferrous; Straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFNF20000-X0\u003c\/td\u003e\n\u003ctd\u003e10–20000 µm\u003c\/td\u003e\n\u003ctd\u003eFerrous and non-ferrous; Wide-range straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFNF2000-X1\u003c\/td\u003e\n\u003ctd\u003e0–2000 µm\u003c\/td\u003e\n\u003ctd\u003eFerrous and non-ferrous; 90 Degree right-angle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF2000-X2\u003c\/td\u003e\n\u003ctd\u003e0–2000 µm\u003c\/td\u003e\n\u003ctd\u003eFerrous; 90 Degree long-rod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF2000-X2\u003c\/td\u003e\n\u003ctd\u003e0–2000 µm\u003c\/td\u003e\n\u003ctd\u003eNon-ferrous; 90 Degree long-rod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe NF1600-X0 range is 0–1600 µm. The FNF20000-X0 starts at 10 µm and is intended for thicker coatings; its 20000 µm upper limit does not apply to the other probe options.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coating-thickness-gauge-ls227-touchscreen.jpg?v=1793701453\" alt=\"LS227 touchscreen showing coating thickness and inspection data\" width=\"990\" height=\"782\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS227 touchscreen showing coating thickness and inspection data\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eTouchscreen QC and grouped inspection records\u003c\/h3\u003e\n\u003cp\u003eThe 3.5-inch touchscreen displays readings together with maximum, minimum, average and standard deviation. Configure QC thickness limits for acceptance checks and organize measurements by workpiece or batch. Storage supports up to 100 groups and 10000 records in total across all groups.\u003c\/p\u003e\n\u003cp\u003eZero adjustment and one- to five-point calibration are supported. The following accuracy specifications require five-point calibration; H is the reference thickness.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eProbe\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eAccuracy after five-point calibration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eInterval\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eF600-X0\u003c\/td\u003e\n\u003ctd\u003e±(2%H + 0.3 µm)\u003c\/td\u003e\n\u003ctd\u003e1.5 s single; 0.4 s continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF1600-X0\u003c\/td\u003e\n\u003ctd\u003e±(2%H + 0.3 µm)\u003c\/td\u003e\n\u003ctd\u003e0.4 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFNF2000-X0\u003c\/td\u003e\n\u003ctd\u003eH \u0026lt; 1000 µm: ±(2%H + 1 µm); H ≥ 1000 µm: ±3%H\u003c\/td\u003e\n\u003ctd\u003e0.8 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFNF5000-X0\u003c\/td\u003e\n\u003ctd\u003eH \u0026lt; 1000 µm: ±(2%H + 1 µm); 1000 ≤ H \u0026lt; 3000 µm: ±3%H; H ≥ 3000 µm: ±5%H\u003c\/td\u003e\n\u003ctd\u003e0.8 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFNF20000-X0\u003c\/td\u003e\n\u003ctd\u003eH \u0026lt; 15000 µm: ±(3%H + 2 µm); H ≥ 15000 µm: ±5%H\u003c\/td\u003e\n\u003ctd\u003e0.8 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFNF2000-X1\u003c\/td\u003e\n\u003ctd\u003eH \u0026lt; 1000 µm: ±(2%H + 1 µm); H ≥ 1000 µm: ±3%H\u003c\/td\u003e\n\u003ctd\u003e0.8 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF2000-X2\u003c\/td\u003e\n\u003ctd\u003eH \u0026lt; 1000 µm: ±(2%H + 1 µm); H ≥ 1000 µm: ±3%H\u003c\/td\u003e\n\u003ctd\u003e0.6 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF2000-X2\u003c\/td\u003e\n\u003ctd\u003eH \u0026lt; 1000 µm: ±(2%H + 1 µm); H ≥ 1000 µm: ±3%H\u003c\/td\u003e\n\u003ctd\u003e0.4 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coating-thickness-gauge-ls227-measurement-statistics.jpg?v=1793701460\" alt=\"LS227 display illustrating maximum, minimum, average and standard deviation\" width=\"990\" height=\"783\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS227 display illustrating maximum, minimum, average and standard deviation\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eMain unit and data connections\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e3.5-inch touchscreen; 480 x 320 IPS color display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e3.7 V, 4000 mAh rechargeable lithium battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain unit dimensions\u003c\/th\u003e\n\u003ctd\u003e141 x 71 x 22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain unit weight\u003c\/th\u003e\n\u003ctd\u003eApproximately 200 g including battery; probe weight is additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnits\u003c\/th\u003e\n\u003ctd\u003eµm \/ mm \/ mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZinc coating mass display\u003c\/th\u003e\n\u003ctd\u003eg\/m² available only with F600-X0 or F2000-X2, using zinc density 7.13 g\/cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMobile connection\u003c\/th\u003e\n\u003ctd\u003eBluetooth; UT and HL app for Android; iOS is not supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePC connection\u003c\/th\u003e\n\u003ctd\u003eUSB; Windows software for measurement, record retrieval and Excel export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eWhile connected to the mobile app, the instrument shows the current measurement and does not save readings locally. Use the appropriate recording workflow for the inspection. When choosing a probe, also check its minimum substrate thickness, curvature limits and access requirements against the part.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"LS227 + F600-X0","offer_id":68113962696747,"sku":"THK-H6P3-01","price":604.01,"currency_code":"USD","in_stock":true},{"title":"LS227 + NF1600-X0","offer_id":68113962729515,"sku":"THK-H6P3-02","price":625.89,"currency_code":"USD","in_stock":true},{"title":"LS227 + FNF2000-X0","offer_id":68113962762283,"sku":"THK-H6P3-03","price":342.86,"currency_code":"USD","in_stock":true},{"title":"LS227 + FNF5000-X0","offer_id":68113962795051,"sku":"THK-H6P3-04","price":436.11,"currency_code":"USD","in_stock":true},{"title":"LS227 + FNF20000-X0","offer_id":68113962827819,"sku":"THK-H6P3-05","price":678.05,"currency_code":"USD","in_stock":true},{"title":"LS227 + FNF2000-X1","offer_id":68113962860587,"sku":"THK-H6P3-06","price":676.59,"currency_code":"USD","in_stock":true},{"title":"LS227 + F2000-X2","offer_id":68113962893355,"sku":"THK-H6P3-07","price":651.53,"currency_code":"USD","in_stock":true},{"title":"LS227 + NF2000-X2","offer_id":68113962926123,"sku":"THK-H6P3-08","price":674.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coating-thickness-gauge-ls227-main-unit-probe-square-main-1200-v3.jpg?v=1793779684"},{"product_id":"plating-thickness-gauge-ls225-f500","title":"Plating Thickness Gauge LS225 + F500 - 0-500 µm","description":"\u003cp\u003eThe Linshang LS225 + F500 plating thickness gauge measures non-magnetic coatings on steel, iron and other ferromagnetic metal substrates. The kit pairs one LS225 display unit with one F500 magnetic-induction probe, covering 0–500 µm for thin plating and paint inspection.\u003c\/p\u003e\n\u003ch3\u003eInspect coatings on small metal parts\u003c\/h3\u003e\n\u003cp\u003eUse the F500 probe for compatible zinc, copper, chromium or paint coatings on ferrous parts such as screws, bolts and formed hardware. The minimum measuring area is 7 mm in diameter. Check the substrate thickness and curvature limits before choosing a measurement location; the probe cannot measure every coating and substrate combination.\u003c\/p\u003e\n\u003cp\u003eThe separate cable-connected probe lets you position the tip while keeping the screen in view. Hold the probe perpendicular to the workpiece and lift it clear between single readings. A matching test fixture is optional and is not included in this host-and-probe kit.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/plating-thickness-gauge-ls225-f500-calibration.jpg?v=1793755687\" alt=\"LS225 multi-point calibration with the F500 probe and reference films\" width=\"990\" height=\"1141\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS225 multi-point calibration with the F500 probe and reference films\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eCalibration and recent-reading statistics\u003c\/h3\u003e\n\u003cp\u003ePerform zero adjustment on a suitable uncoated reference before calibration. One- to five-point calibration is available; the accuracy specification below applies after five-point calibration. Prepare calibration films in increasing thickness and keep the probe stable during each reading.\u003c\/p\u003e\n\u003cp\u003eThe display calculates the maximum, minimum, average and standard deviation of the latest nine valid readings. Up to nine recent records are retained after power-off. This supports a short sequence of checks on a workpiece without manually calculating the basic statistics.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/plating-thickness-gauge-ls225-f500-statistics.jpg?v=1793755706\" alt=\"LS225 recent-reading statistics shown during F500 measurement\" width=\"990\" height=\"1260\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS225 recent-reading statistics shown during F500 measurement\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eF500 measurement specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePrinciple and substrate\u003c\/th\u003e\n\u003ctd\u003eMagnetic induction; ferromagnetic metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRange\u003c\/th\u003e\n\u003ctd\u003e0–500 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.1 µm at 0–99.9 µm; 1 µm at 100–500 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy after five-point calibration\u003c\/th\u003e\n\u003ctd\u003e≤±(2%H + 0.3 µm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRepeatability with matching test fixture\u003c\/th\u003e\n\u003ctd\u003e≤±(0.8%H + 0.1 µm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference thickness\u003c\/th\u003e\n\u003ctd\u003eH is the standard\/reference thickness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring interval\u003c\/th\u003e\n\u003ctd\u003e1.5 s in single mode; 0.4 s in continuous mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum measuring area\u003c\/th\u003e\n\u003ctd\u003e7 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum substrate thickness\u003c\/th\u003e\n\u003ctd\u003e0.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum curvature radius\u003c\/th\u003e\n\u003ctd\u003eConvex: 1.5 mm; concave: 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProbe dimensions\u003c\/th\u003e\n\u003ctd\u003e110 x 15 mm, excluding connecting cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnits\u003c\/th\u003e\n\u003ctd\u003eµm \/ mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e240 x 160 dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFour 1.5 V AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHost dimensions\u003c\/th\u003e\n\u003ctd\u003e148 x 76 x 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument weight\u003c\/th\u003e\n\u003ctd\u003e194 g host including batteries; 81 g probe; 275 g combined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating environment\u003c\/th\u003e\n\u003ctd\u003e0–50°C; 0–85% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eChoose the appropriate measuring setup\u003c\/h3\u003e\n\u003cp\u003eUse single measurement mode for precision checks. For repeatability testing under the stated specification, use the matching optional fixture to control probe placement. The repeatability formula is a conditional specification, rather than a fixed 0.1 µm accuracy claim. The kit includes one host and one F500 probe; other probes and the test fixture are separate options.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68119056252971,"sku":"THK-K9S5-01","price":770.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/plating-thickness-gauge-ls225-f500-front-square-main-1200-v3.jpg?v=1793780765"},{"product_id":"large-aperture-spectrophotometer-ls177","title":"Large-Aperture Spectrophotometer LS177 for Powders and Granules","description":"\u003cp\u003eThe Linshang LS177 large-aperture spectrophotometer measures color across a 50mm sample opening. Its benchtop design suits powder, plastic masterbatch, textured cloth and opaque liquid samples, where a wider measurement area helps capture a representative portion of the material. The 7-inch touchscreen displays color values and spectral reflectance for routine incoming-material and production checks.\u003c\/p\u003e\u003ch3\u003eColor measurement across a wider sample\u003c\/h3\u003e\u003cp\u003eD\/8 integrating-sphere geometry with specular reflection included (SCI) provides the measurement basis. A full-spectrum LED illuminates the sample, with reflectance displayed from 400 to 700nm at 10nm intervals. The D65 illuminant and 10-degree observer give a consistent reference for comparing batches under the same settings. A reading takes approximately 1.5 seconds.\u003c\/p\u003e\u003cp\u003eAvailable outputs include CIE Lab, Luv, LCh, Yxy, RGB and CMYK, along with whiteness, yellowness and reflectance values. The instrument also offers several color-difference formulas, including ΔE*ab and ΔE00, so a quality-control procedure can use its chosen calculation.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/large-aperture-spectrophotometer-ls177-reflectance-curve.jpg?v=1793766482\" alt=\"LS177 spectral reflectance curve on the touchscreen\" width=\"1000\" height=\"1450\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS177 spectral reflectance curve on the touchscreen\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRepeatable batch comparison\u003c\/h3\u003e\u003cp\u003eSave a reference color and compare subsequent samples against it. An adjustable color-difference threshold supports pass\/fail decisions based on your own acceptance criteria. Repeatability is specified as a standard deviation of ΔE*ab ≤0.03 for 30 measurements of a white calibration tile at three-second intervals after calibration.\u003c\/p\u003e\u003ch3\u003eDetails and specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS177\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOptical geometry\u003c\/th\u003e\n\u003ctd\u003eD\/8, SCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement aperture\u003c\/th\u003e\n\u003ctd\u003e50mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIlluminant \/ observer\u003c\/th\u003e\n\u003ctd\u003eD65 \/ 10 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReflectance display\u003c\/th\u003e\n\u003ctd\u003e400–700nm, 10nm interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement time\u003c\/th\u003e\n\u003ctd\u003eApprox. 1.5s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInter-instrument agreement\u003c\/th\u003e\n\u003ctd\u003eΔE*ab ≤0.4, average of 12 BCRA II color tiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTouchscreen\u003c\/th\u003e\n\u003ctd\u003e7-inch, 1024 x 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eBluetooth and USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003eAC 100–277V, 50\/60Hz, 0.4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions \/ net weight\u003c\/th\u003e\n\u003ctd\u003e211 x 264 x 155mm \/ approx. 3.29kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/large-aperture-spectrophotometer-ls177-pc-software.jpg?v=1793766492\" alt=\"LS177 connected to Windows color measurement software\" width=\"1000\" height=\"1189\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS177 connected to Windows color measurement software\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eData review and sample handling\u003c\/h3\u003e\u003cp\u003eBluetooth connects to the LSColor mobile app, while USB supports Windows software for reviewing measurements, exporting data and preparing reports. Keep the calibration tile and sample opening clean, and use consistent sample depth, coverage and placement across a batch. Opaque liquids can be presented in suitable sample cuvettes. Consistent preparation is especially important for loose powders and uneven granules.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68119861624875,"sku":"SPC-C8R5-01","price":2028.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/large-aperture-spectrophotometer-ls177-front-granules-square-main-1200-v3.jpg?v=1793780591"},{"product_id":"coffee-roast-colorimeter-ls177c","title":"Coffee Roast Colorimeter LS177C with SCAA and HCCI Readings","description":"\u003cp\u003eCompare roast color between coffee batches with the Linshang LS177C coffee roast colorimeter. A 50mm measurement aperture accommodates coffee bean samples, and the 7-inch touchscreen presents SCAA\/Agtron, HCCI, roast-degree and CIE Lab readings. The benchtop format suits roasters who need a consistent numerical record alongside their existing roast assessment.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coffee-roast-colorimeter-ls177c-roast-index-display.jpg?v=1793766555\" alt=\"LS177C display showing SCAA, HCCI and roast color readings\" width=\"990\" height=\"610\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS177C display showing SCAA, HCCI and roast color readings\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRoast indices and color comparison\u003c\/h3\u003e\u003cp\u003eThe LS177C uses D\/8 SCI optical geometry with a D65 illuminant and 10-degree observer. A measurement takes approximately 1.5 seconds. Coffee-specific sample dishes provide a repeatable way to present the material over the opening. Keep the fill level and bean placement consistent when comparing batches, since an uneven sample surface can affect the reading.\u003c\/p\u003e\u003cp\u003eUse the roast-index display to record a batch result, or compare a sample with a saved reference using CIE Lab and ΔE*ab. Color readings describe the measured sample appearance. Roast-profile decisions can then incorporate the other checks used in your production process.\u003c\/p\u003e\u003ch3\u003eInstrument details\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS177C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCoffee outputs\u003c\/th\u003e\n\u003ctd\u003eSCAA\/Agtron number, HCCI and roast degree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor outputs\u003c\/th\u003e\n\u003ctd\u003eCIE Lab and ΔE*ab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAperture \/ geometry\u003c\/th\u003e\n\u003ctd\u003e50mm \/ D\/8 SCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIlluminant \/ observer\u003c\/th\u003e\n\u003ctd\u003eD65 \/ 10 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement time\u003c\/th\u003e\n\u003ctd\u003eApprox. 1.5s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003eStandard deviation ΔE*ab ≤0.03 for 30 white-tile readings at 3s intervals after calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInter-instrument agreement\u003c\/th\u003e\n\u003ctd\u003eΔE*ab ≤0.4, average of 12 BCRA II tiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTouchscreen\u003c\/th\u003e\n\u003ctd\u003e7-inch, 1024 x 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003eAC 100–277V, 50\/60Hz, 0.4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnectivity \/ net weight\u003c\/th\u003e\n\u003ctd\u003eUSB and Bluetooth \/ approx. 3.29kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coffee-roast-colorimeter-ls177c-user-calibration.jpg?v=1793766564\" alt=\"LS177C user calibration settings for coffee roast indices\" width=\"990\" height=\"664\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS177C user calibration settings for coffee roast indices\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eCalibration and reporting\u003c\/h3\u003e\u003cp\u003eWhite-tile calibration establishes the optical reference. The coffee settings also support multipoint SCAA calibration and an HCCI coefficient, allowing the instrument to follow the reference procedure used in your workflow. Apply the same settings to both a reference batch and later comparisons.\u003c\/p\u003e\u003cp\u003eBluetooth links the instrument to the LSColor mobile app, and USB connects it to Windows software. Review measurements, export records and prepare reports for batch documentation. Clean the sample dish between materials and keep the measurement opening clear so residual beans or particles do not influence the next sample.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68119862444075,"sku":"CLR-K6V3-01","price":1352.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/coffee-roast-colorimeter-ls177c-front-beans-square-main-1200-v3.jpg?v=1793780601"},{"product_id":"small-aperture-spectrophotometer-ls178","title":"Small-Aperture Spectrophotometer LS178 with 1mm Split Probe","description":"\u003cp\u003eThe Linshang LS178 small-aperture spectrophotometer uses a separate 1mm probe to measure color on small components and narrow colored areas. The cabled probe can be positioned independently of the touchscreen unit, helping you place the measurement opening against fittings, molded parts, cable surfaces and other samples with limited accessible color area.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/small-aperture-spectrophotometer-ls178-one-mm-aperture.jpg?v=1793766613\" alt=\"LS178 probe underside showing the 1mm measurement aperture\" width=\"990\" height=\"734\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS178 probe underside showing the 1mm measurement aperture\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003ePositioning small samples\u003c\/h3\u003e\u003cp\u003ePlace the probe against the sample or turn its opening upward to present a small item from above. The sample must cover the aperture and remain steady during the approximately one-second reading. Consistent contact and orientation help comparisons between similar parts, especially when the surface is curved or textured.\u003c\/p\u003e\u003cp\u003eD\/8 SCI geometry includes specular reflection in the measurement. A full-spectrum LED, D65 illuminant and 10-degree observer form the optical reference. Reflectance values are displayed from 400 to 700nm at 10nm intervals, alongside the selected color coordinates.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/small-aperture-spectrophotometer-ls178-color-formulas.jpg?v=1793766624\" alt=\"LS178 color-space and color-difference formula settings\" width=\"990\" height=\"788\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS178 color-space and color-difference formula settings\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eColor data and connectivity\u003c\/h3\u003e\u003cp\u003eThe touchscreen offers CIE Lab, LCh, Luv, Yxy, RGB and CMYK, plus whiteness, yellowness and reflectance options. Color-difference calculations include ΔE*ab and ΔE00. Save a reference, measure the next part and apply your chosen tolerance to a pass\/fail comparison.\u003c\/p\u003e\u003cp\u003eBluetooth connects to the LSColor mobile app, while USB supports Windows software for data review, export and report preparation. The handheld unit contains a rechargeable battery and uses a USB Type-C connection for charging.\u003c\/p\u003e\u003ch3\u003eDetails and specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement aperture\u003c\/th\u003e\n\u003ctd\u003e1mm, separate cabled probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGeometry\u003c\/th\u003e\n\u003ctd\u003eD\/8 SCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIlluminant \/ observer\u003c\/th\u003e\n\u003ctd\u003eD65 \/ 10 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReflectance display\u003c\/th\u003e\n\u003ctd\u003e400–700nm, 10nm interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement time\u003c\/th\u003e\n\u003ctd\u003eApprox. 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003eStandard deviation ΔE*ab ≤0.03 for 30 white-tile readings at 3s intervals after calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInter-instrument agreement\u003c\/th\u003e\n\u003ctd\u003eΔE*ab ≤0.4, average of 12 BCRA II tiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTouchscreen\u003c\/th\u003e\n\u003ctd\u003e3.5-inch, 480 x 320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e3.7V, 4000mAh rechargeable lithium battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface \/ net weight\u003c\/th\u003e\n\u003ctd\u003eBluetooth and USB Type-C \/ approx. 390g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMeasurement preparation\u003c\/h3\u003e\u003cp\u003eCalibrate with the white reference tile and keep the opening clean. Select the same color space, comparison formula and tolerance for both reference and sample measurements. A 1mm opening targets a local area, so check several representative points when the part has a visibly uneven color pattern.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68119863328811,"sku":"SPC-P9H4-01","price":1310.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/small-aperture-spectrophotometer-ls178-front-split-probe-square-main-1200-v3.jpg?v=1793780622"},{"product_id":"printing-colorimeter-ls372-4mm","title":"Printing Colorimeter LS372 with 4mm Aperture and D50 Reference","description":"\u003cp\u003eCheck color differences on prints, labels and packaging with the Linshang LS372 printing colorimeter. A 4mm aperture targets small color areas, while the D50 reference and 2-degree observer suit a print-focused measurement workflow. The upright handheld body and 3.5-inch touchscreen make reference and sample readings accessible at the work surface.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/printing-colorimeter-ls372-aperture-positioning.jpg?v=1793766691\" alt=\"LS372 4mm measurement aperture and sample positioning plate\" width=\"990\" height=\"783\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS372 4mm measurement aperture and sample positioning plate\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eSmall-area print checks\u003c\/h3\u003e\u003cp\u003eThe LS372 uses 45\/0 optical geometry and takes a reading in approximately one second. Its positioning plate helps locate the aperture over the intended patch. Place the instrument on a clean, flat area with enough uniform color to cover the opening, and use consistent sample backing and placement for comparisons.\u003c\/p\u003e\u003cp\u003eRead CIE Lab, LCh, Luv and Yxy coordinates, or choose other available outputs such as RGB and CMYK. Spectral reflectance is displayed from 400 to 700nm at 10nm intervals. Several color-difference formulas are available, including ΔE*ab and ΔE00.\u003c\/p\u003e\u003ch3\u003eReference-based quality control\u003c\/h3\u003e\u003cp\u003eMeasure and save a reference, then compare production samples against it. Set the acceptance threshold to match the job's requirements so the pass\/fail indication follows the tolerance selected by your team. A built-in white calibration tile in the protective bottom cap provides the optical calibration reference.\u003c\/p\u003e\u003ch3\u003eDetails and specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS372\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOptical geometry\u003c\/th\u003e\n\u003ctd\u003e45\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement aperture\u003c\/th\u003e\n\u003ctd\u003e4mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIlluminant \/ observer\u003c\/th\u003e\n\u003ctd\u003eD50 \/ 2 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReflectance display\u003c\/th\u003e\n\u003ctd\u003e400–700nm, 10nm interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement time\u003c\/th\u003e\n\u003ctd\u003eApprox. 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003eStandard deviation ΔE*ab ≤0.03 for 30 white-tile readings at 3s intervals after calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTouchscreen\u003c\/th\u003e\n\u003ctd\u003e3.5-inch, 480 x 320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e3.7V, 4000mAh rechargeable lithium battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eBluetooth and USB Type-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions \/ net weight\u003c\/th\u003e\n\u003ctd\u003e86 x 62.5 x 158mm \/ approx. 225g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/printing-colorimeter-ls372-app-pc-reporting.jpg?v=1793766699\" alt=\"LS372 mobile app, Windows software and color measurement report\" width=\"990\" height=\"743\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS372 mobile app, Windows software and color measurement report\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eStore and share comparison records\u003c\/h3\u003e\u003cp\u003eConnect to the LSColor mobile app by Bluetooth or use the Windows software over USB to review measurements, export data and prepare reports. Keep the same illuminant, observer and formula settings when sharing reference values between checks. The rechargeable battery supports portable use, with charging through the Type-C connection.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68119864311851,"sku":"CLR-T5M8-01","price":249.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/printing-colorimeter-ls372-front-view-square-main-1200-v3.jpg?v=1793781216"},{"product_id":"window-film-tint-meter-ls161","title":"Window Film Tint Meter LS161 with 940nm IR Channel","description":"\u003cp\u003eThe Linshang LS161 window film tint meter compares visible light transmission with UV and infrared rejection on thin film samples. Its 940nm infrared channel helps distinguish how films respond at that test wavelength. A compact gray body and color display make it practical for sample demonstrations, receiving checks and film quality-control work.\u003c\/p\u003e\u003ch3\u003eThree optical readings on one display\u003c\/h3\u003e\u003cp\u003eInsert a film less than 0.8mm thick into the slot to see the result. The visible channel follows the CIE photopic response across 380–760nm, while the ultraviolet channel uses a 365nm peak wavelength. Select visible transmission alone, three transmission readings, or visible transmission with UV and IR rejection.\u003c\/p\u003e\u003cp\u003eThe infrared result is specific to the 940nm channel. When comparing film samples, use the same instrument and display mode so each reading describes the same optical quantity. The slot is intended for thin film samples, with the material covering the measurement area.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/window-film-tint-meter-ls161-rotating-display.jpg?v=1793767266\" alt=\"LS161 display rotating for readings in either orientation\" width=\"990\" height=\"616\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS161 display rotating for readings in either orientation\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRead and retain film results\u003c\/h3\u003e\u003cp\u003eThe 240 x 240 TFT screen uses colored progress bars to make the selected readings easy to scan. Its display rotates through 180 degrees for viewing from either orientation. Press HOLD while measuring to retain the values after removing the film, then release HOLD to resume testing.\u003c\/p\u003e\u003ch3\u003eLS161 specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInfrared channel\u003c\/th\u003e\n\u003ctd\u003e940nm peak wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUV channel\u003c\/th\u003e\n\u003ctd\u003e365nm peak wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVisible response\u003c\/th\u003e\n\u003ctd\u003e380–760nm, CIE photopic response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±2% for colorless, uniform light-transmitting material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSample thickness\u003c\/th\u003e\n\u003ctd\u003eLess than 0.8mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e240 x 240 TFT color screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFour AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e101 x 52 x 25.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003eApprox. 70g excluding batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/window-film-tint-meter-ls161-hold-function.jpg?v=1793767277\" alt=\"LS161 HOLD function retaining film test readings\" width=\"990\" height=\"615\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS161 HOLD function retaining film test readings\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eBefore each comparison\u003c\/h3\u003e\u003cp\u003eStart the instrument with the test slot empty so its self-test and calibration can complete. Four replaceable AAA alkaline batteries power the meter, and automatic shutdown follows three minutes without button operation. Keep the slot clear of dirt and avoid corrosive materials during handling.\u003c\/p\u003e\u003cp\u003eUse the retained reading to record or discuss a sample result. The single-button operation and pocket-sized format suit repeated checks on separate film pieces where a full glass panel does not need to fit through the slot.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68119901143083,"sku":"TNT-J7D4-01","price":86.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/window-film-tint-meter-ls161-front-display-square-main-1200-v3.jpg?v=1793780160"},{"product_id":"window-film-tint-meter-ls161a","title":"1400nm Window Film Tint Meter LS161A with Color Display","description":"\u003cp\u003eA 1400nm infrared channel gives the Linshang LS161A window film tint meter a distinct reference for comparing solar film samples. It reads visible light transmission and UV\/IR rejection, with selectable display combinations on a color screen. The blue pocket-sized instrument is intended for thin films that fit its narrow measurement slot.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/window-film-tint-meter-ls161a-ir-channel-comparison.jpg?v=1793767344\" alt=\"LS161 and LS161A labeled with 940nm and 1400nm infrared channels\" width=\"1000\" height=\"1000\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS161 and LS161A labeled with 940nm and 1400nm infrared channels\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eChoose the infrared reference for your film check\u003c\/h3\u003e\u003cp\u003eThe LS161A measures infrared response at a peak wavelength of 1400nm. This channel differs from the 940nm reference used by the LS161, so identify the wavelength when recording or sharing results. Use a consistent channel to compare films within your own sample set.\u003c\/p\u003e\u003cp\u003eThe ultraviolet channel has a 365nm peak wavelength, and the visible channel follows the CIE photopic response over 380–760nm. Choose VLT alone, VLT\/UVT\/IRT, or VLT with ultraviolet and infrared rejection. These settings let you present the optical readings relevant to the comparison being made.\u003c\/p\u003e\u003ch3\u003eColor display and retained readings\u003c\/h3\u003e\u003cp\u003eColor-coded progress bars accompany the measurement values on the 240 x 240 TFT screen. Automatic 180-degree display rotation makes readings accessible when the meter is turned around. HOLD freezes the result so it can be read after the sample is removed. Cancel HOLD before starting another measurement.\u003c\/p\u003e\u003ch3\u003eLS161A specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS161A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInfrared channel\u003c\/th\u003e\n\u003ctd\u003e1400nm peak wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUV channel\u003c\/th\u003e\n\u003ctd\u003e365nm peak wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVisible response\u003c\/th\u003e\n\u003ctd\u003e380–760nm, CIE photopic response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±2% for colorless, uniform light-transmitting material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSample thickness\u003c\/th\u003e\n\u003ctd\u003eLess than 0.8mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e240 x 240 TFT color screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFour AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e101 x 52 x 25.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003eApprox. 70g excluding batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/window-film-tint-meter-ls161a-sample-thickness.jpg?v=1793767357\" alt=\"LS161A thin-film measurement slot shown with its 0.8mm opening\" width=\"1000\" height=\"1000\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS161A thin-film measurement slot shown with its 0.8mm opening\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eSample fit and routine use\u003c\/h3\u003e\u003cp\u003eUse film less than 0.8mm thick and position it across the slot's optical path. Switch the meter on with the slot empty to allow the self-test and calibration to finish. Four AAA alkaline batteries provide power, with automatic shutdown after three minutes without button operation.\u003c\/p\u003e\u003cp\u003eThe meter suits portable film demonstrations and routine comparisons of individual film pieces. Keep the sample and opening clean, then record the selected display mode with the result so a later check can use the same settings.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68119901405227,"sku":"TNT-V8C5-01","price":136.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/window-film-tint-meter-ls161a-held-comparison-square-main-1200-v3.jpg?v=1793780192"}],"url":"https:\/\/mcooh.com\/collections\/new-arrivals.oembed?page=4","provider":"Mcooh","version":"1.0","type":"link"}