{"title":"Optical Transmission \u0026 Density Meters","description":"\u003cp\u003eOptical transmission and density meters compare how light passes through lenses, optical filters, glass, film and other supported samples. This collection focuses on component inspection, small test apertures, split-probe visible transmission and optical-density measurement. Choose by wavelength channel, sample clarity, aperture size and the required measurement geometry. Selected models measure UV or infrared transmission alongside visible light, while the optical-density model supports film and diffusing materials. Confirm the sample support and probe arrangement for each instrument. For automotive or architectural solar-film comparisons, browse our \u003ca href=\"\/collections\/tint-meter\"\u003ewindow tint meters\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eChoose the optical measurement setup\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable\u003e\n\u003ccaption\u003eChoose the optical measurement setup\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eProduct starting point\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to compare\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/blue-light-lens-transmission-meter-ls108\"\u003eLS108 lens transmission meter\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCheck the lens sample, supported light channels and UV400 indication.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/infrared-transmission-meter-ls108d\"\u003eLS108D small-aperture meter\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCompare the clear measurement area with the stated aperture and light channel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/split-probe-light-transmittance-meter-ls116\"\u003eLS116 split-probe meter\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCheck access to both sides of a clear sample and probe alignment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/optical-density-meter-ls117\"\u003eLS117 optical-density meter\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMatch film or diffusing samples to the documented optical-density method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","products":[{"product_id":"blue-light-lens-transmission-meter-ls108","title":"Blue Light Lens Transmission Meter LS108 with UV400 Indicator","description":"\u003cp\u003eThe Linshang LS108 blue light lens transmission meter compares optical performance of eyeglass lenses, sunglasses and other small transparent samples. A single 1mm test aperture provides 395nm violet transmission, 430nm blue light transmission and photopic visible light transmission. All three results appear together on a color LCD, making it practical to compare different lens samples at the same test position.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/blue-light-lens-transmission-meter-ls108-three-optical-channels.jpg?v=1793770432\" alt=\"LS108 optical paths for 395nm, 430nm and visible light transmission\" width=\"990\" height=\"670\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS108 optical paths for 395nm, 430nm and visible light transmission\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eLens testing at three optical channels\u003c\/h3\u003e\u003cp\u003eThe 395nm and 430nm channels give wavelength-specific readings. The visible channel uses a 380–760nm response matched to the CIE photopic luminosity function. This combination helps optical retailers and lens processors compare transmission behavior without changing instruments between these measurements.\u003c\/p\u003e\u003cp\u003eFour display interfaces provide transmission and rejection views together with a UV400 indicator. The indicator is a screening aid for the tested sample. Use the individual channel readings when comparing lens types or recording a specific measurement.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/blue-light-lens-transmission-meter-ls108-display-modes.jpg?v=1793770442\" alt=\"Four LS108 display interfaces for transmission and rejection readings\" width=\"990\" height=\"748\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eFour LS108 display interfaces for transmission and rejection readings\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eSet up a repeatable comparison\u003c\/h3\u003e\u003cp\u003eStart the instrument with the test position empty and allow its automatic calibration to establish the 100% reference. Place the intended test area of the lens over the aperture and keep its position steady while reading the screen. The small aperture is useful for finished lenses mounted in a frame as well as loose samples.\u003c\/p\u003e\u003cp\u003eChinese and English display options support daily use at a counter or inspection bench. Consistent sample placement and clean optical surfaces help maintain comparable results across a batch. The stated accuracy applies to colorless, uniform transparent materials within the specified transmission range.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement channels\u003c\/th\u003e\n\u003ctd\u003e395nm violet, 430nm blue and 380–760nm photopic visible light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest aperture\u003c\/th\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay resolution\u003c\/th\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransmittance accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% for colorless, uniform transparent materials within 0–90% transmittance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003eDC 5V \/ 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e170 × 180 × 144 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument weight\u003c\/th\u003e\n\u003ctd\u003e1,570 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68120160763947,"sku":"ELE-A7K4-01","price":490.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/blue-light-lens-transmission-meter-ls108-front-with-glasses-square-main-1200-v3.jpg?v=1793779748"},{"product_id":"infrared-transmission-meter-ls108a","title":"Infrared Transmission Meter LS108A with 1 mm Aperture","description":"\u003cp\u003eThe Linshang LS108A infrared transmission meter measures 850nm IR, 940nm IR and 550nm visible-light transmission through one 1 mm aperture. It is designed for inspecting infrared filter windows, remote-control components and small transmission areas such as the infrared ink openings in phone cover glass. The color display presents the selected channel combination for a direct comparison between parts.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/infrared-transmission-meter-ls108a-aperture-comparison.jpg?v=1793770513\" alt=\"LS108A 1mm and LS108D 0.5mm aperture comparison\" width=\"990\" height=\"650\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS108A 1mm and LS108D 0.5mm aperture comparison\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003ePosition small optical parts\u003c\/h3\u003e\u003cp\u003eAll three channels share the same test hole, reducing the need to reposition a small sample between wavelengths. An alignment indicator helps locate the measurement point. The 1mm aperture provides a compact test area. The related LS108D uses a smaller 0.5mm aperture for narrower openings.\u003c\/p\u003e\u003cp\u003eThe visible reading is measured at 550nm. Select a three-channel view or a two-channel view combining 550nm with either infrared wavelength to suit the part under inspection.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/infrared-transmission-meter-ls108a-pc-measurement.jpg?v=1793770505\" alt=\"LS108A connected to a computer for transmission inspection\" width=\"2000\" height=\"1333\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS108A connected to a computer for transmission inspection\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRecord results with USB PC software\u003c\/h3\u003e\u003cp\u003eA USB Type-C connection links the meter to its PC software for ongoing measurements. The software supports upper and lower QC limits, pass\/fail evaluation, measurement counting and pass-rate summaries, helping operators screen batches against their chosen transmission criteria.\u003c\/p\u003e\u003cp\u003eFor startup calibration, keep the optical path empty until the 100% reference is established. Position the sample over the aperture without blocking the light path elsewhere. Use consistent orientation when comparing coated or patterned parts. The accuracy specification applies to colorless, uniform transparent materials within 0–90% transmission.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOptical channels\u003c\/th\u003e\n\u003ctd\u003e850nm IR, 940nm IR and 550nm visible light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest aperture\u003c\/th\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePC connection\u003c\/th\u003e\n\u003ctd\u003eUSB Type-C, QC inspection software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay resolution\u003c\/th\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransmittance accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% for colorless, uniform transparent materials within 0–90% transmittance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003eDC 5V \/ 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e170 × 180 × 144 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument weight\u003c\/th\u003e\n\u003ctd\u003e1,570 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68120161681451,"sku":"ELE-B8T6-01","price":480.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/infrared-transmission-meter-ls108a-front-view-square-main-1200-v3.jpg?v=1793779762"},{"product_id":"infrared-transmission-meter-ls108d","title":"Infrared Transmission Meter LS108D with 0.5 mm Aperture","description":"\u003cp\u003eThe Linshang LS108D infrared transmission meter measures 850nm IR, 940nm IR and 550nm visible-light transmission through one 0.5 mm aperture. It is designed for inspecting infrared filter windows, remote-control components and small transmission areas such as the infrared ink openings in phone cover glass. The color display presents the selected channel combination for a direct comparison between parts.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/infrared-transmission-meter-ls108d-aperture-comparison.jpg?v=1793770581\" alt=\"LS108A 1mm and LS108D 0.5mm aperture comparison\" width=\"990\" height=\"650\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS108A 1mm and LS108D 0.5mm aperture comparison\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003ePosition small optical parts\u003c\/h3\u003e\u003cp\u003eAll three channels share the same test hole, reducing the need to reposition a small sample between wavelengths. An alignment indicator helps locate the measurement point. The 0.5mm aperture is suited to particularly small openings. The related LS108A uses a larger 1mm aperture.\u003c\/p\u003e\u003cp\u003eThe visible reading is measured at 550nm. Select a three-channel view or a two-channel view combining 550nm with either infrared wavelength to suit the part under inspection.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/infrared-transmission-meter-ls108d-pc-measurement.jpg?v=1793770572\" alt=\"LS108D connected to a computer for transmission inspection\" width=\"2000\" height=\"1125\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS108D connected to a computer for transmission inspection\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRecord results with USB PC software\u003c\/h3\u003e\u003cp\u003eA USB Type-C connection links the meter to its PC software for ongoing measurements. The software supports upper and lower QC limits, pass\/fail evaluation, measurement counting and pass-rate summaries, helping operators screen batches against their chosen transmission criteria.\u003c\/p\u003e\u003cp\u003eFor startup calibration, keep the optical path empty until the 100% reference is established. Position the sample over the aperture without blocking the light path elsewhere. Use consistent orientation when comparing coated or patterned parts. The accuracy specification applies to colorless, uniform transparent materials within 0–90% transmission.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOptical channels\u003c\/th\u003e\n\u003ctd\u003e850nm IR, 940nm IR and 550nm visible light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest aperture\u003c\/th\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePC connection\u003c\/th\u003e\n\u003ctd\u003eUSB Type-C, QC inspection software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay resolution\u003c\/th\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransmittance accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% for colorless, uniform transparent materials within 0–90% transmittance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003eDC 5V \/ 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e170 × 180 × 144 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument weight\u003c\/th\u003e\n\u003ctd\u003e1,570 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68120162074667,"sku":"ELE-C9N5-01","price":688.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/infrared-transmission-meter-ls108d-front-view-square-main-1200-v3.jpg?v=1793779775"},{"product_id":"uv-ir-visible-transmission-meter-ls108h","title":"UV IR Visible Transmission Meter LS108H with 1mm Aperture","description":"\u003cp\u003eThe Linshang LS108H UV IR visible transmission meter brings three optical measurements together for glass, lenses, plastics and other uniform transparent materials. It measures 365nm UV transmission, 940nm infrared transmission and visible light transmission through a single 1mm aperture. A parallel light path supports measurements on both thin and thicker samples placed in the optical opening.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-ir-visible-transmission-meter-ls108h-three-channel-path.jpg?v=1793770642\" alt=\"LS108H shared optical path for visible light 940nm IR and 365nm UV\" width=\"990\" height=\"659\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS108H shared optical path for visible light 940nm IR and 365nm UV\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eThree readings from one test position\u003c\/h3\u003e\u003cp\u003eThe visible channel covers 380–760nm with a response matched to the CIE photopic luminosity function. UV and infrared channels provide readings at their specified wavelengths. Results appear together on the color LCD, so an operator can see how the same test point behaves in all three channels.\u003c\/p\u003e\u003cp\u003eThis arrangement is useful for comparing coated glass, molded plastic windows and small lens samples. The compact test spot helps isolate the area of interest while the shared light path avoids moving the sample between separate optical tests.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-ir-visible-transmission-meter-ls108h-one-mm-aperture.jpg?v=1793770652\" alt=\"LS108H 1mm aperture for measuring small transparent materials\" width=\"990\" height=\"659\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS108H 1mm aperture for measuring small transparent materials\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eCompare samples consistently\u003c\/h3\u003e\u003cp\u003ePower on with no sample in the measurement path and allow the instrument to establish its 100% reference. Place the intended area of the material over the aperture and keep it stable while comparing the readings. Chinese and English display choices are available.\u003c\/p\u003e\u003cp\u003eUse clean surfaces and the same sample orientation when checking a batch. The stated transmission accuracy applies to colorless, uniform transparent materials within 0–90% transmission. For colored, patterned or scattering specimens, select the test method according to the material and the intended comparison.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement channels\u003c\/th\u003e\n\u003ctd\u003e365nm UV, 940nm IR and 380–760nm photopic visible light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest aperture\u003c\/th\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOptical path\u003c\/th\u003e\n\u003ctd\u003eParallel light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay resolution\u003c\/th\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransmittance accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% for colorless, uniform transparent materials within 0–90% transmittance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003eDC 5V \/ 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e170 × 180 × 144 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument weight\u003c\/th\u003e\n\u003ctd\u003e1,570 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68120162304043,"sku":"ELE-D6P8-01","price":505.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-ir-visible-transmission-meter-ls108h-front-glass-square-main-1200-v3.jpg?v=1793779786"},{"product_id":"split-probe-light-transmittance-meter-ls116","title":"Split-Probe Light Transmittance Meter LS116 for Clear Materials","description":"\u003cp\u003eThe Linshang LS116 light transmittance meter measures photopic visible transmission through clear, uniform glass, film, acrylic and other transparent materials. Its separate light-source and receiving probes can be positioned on opposite sides of an installed panel or placed in the supplied pedestal for bench measurements. The handheld display keeps the reading accessible when the sample is large or awkward to reach.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/light-transmittance-meter-ls116-two-measurement-setups.jpg?v=1793770708\" alt=\"LS116 field measurement and pedestal measurement setups\" width=\"990\" height=\"630\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS116 field measurement and pedestal measurement setups\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eUse split probes in the field or on a pedestal\u003c\/h3\u003e\u003cp\u003eThe parallel optical path covers a transmission range from 0.001% to 99.8%. A 380–760nm spectral response matched to the CIE photopic luminosity function supports visible-transmission comparisons. Probe cables provide a 1m connection for positioning around the specimen.\u003c\/p\u003e\u003cp\u003eThe pedestal holds the probes in alignment for repeated checks. Remove the probes from the holder for larger glass panels, maintaining alignment across the selected test point. HOLD freezes a reading, and the instrument stores up to nine measurements for review.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/light-transmittance-meter-ls116-thick-glass-test.jpg?v=1793770720\" alt=\"LS116 split probes aligned across a thick glass sample\" width=\"2000\" height=\"1123\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS116 split probes aligned across a thick glass sample\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eMatch the setup to the material\u003c\/h3\u003e\u003cp\u003eUse samples larger than 10mm in diameter and less than 100mm thick. For startup, align the probes with an empty light path and allow the warm-up and calibration sequence to establish the 100% reference. Keep the same alignment and control ambient light during measurements, especially for samples with low transmission.\u003c\/p\u003e\u003cp\u003eThe stated ±1% accuracy applies to colorless, uniform transparent materials. Four AAA alkaline batteries power the portable instrument. Its automatic shutdown can be disabled when a longer inspection session is required.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVisible response\u003c\/th\u003e\n\u003ctd\u003e380–760nm, CIE photopic response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransmission range\u003c\/th\u003e\n\u003ctd\u003e0.001–99.8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.001% at 0–10%, 0.01% at 10–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±1% for colorless, uniform transparent materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSample size\u003c\/th\u003e\n\u003ctd\u003eDiameter greater than 10mm, thickness less than 100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStored readings\u003c\/th\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003e4 × AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHandheld dimensions\u003c\/th\u003e\n\u003ctd\u003e148 × 76 × 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument weight\u003c\/th\u003e\n\u003ctd\u003e622 g without batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68120162566187,"sku":"ELE-E7V9-01","price":516.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/light-transmittance-meter-ls116-front-glass-square-main-1200-v3.jpg?v=1793779955"},{"product_id":"optical-density-meter-ls117","title":"Optical Density Meter LS117 for Film and Diffusing Materials","description":"\u003cp\u003eThe Linshang LS117 optical density meter measures 0–6 OD and visible transmittance for film and light-diffusing materials. Typical samples include aluminized film, photographic film, opalescent acrylic, frosted sheets and lamp diffusers. Its separate light-source and receiving probes can be mounted in a fixed holder or positioned by hand to suit the shape of the specimen.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/optical-density-meter-ls117-od-transmission-screen.jpg?v=1793770779\" alt=\"LS117 screen displaying optical density and transmittance together\" width=\"990\" height=\"699\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS117 screen displaying optical density and transmittance together\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRead density and transmission together\u003c\/h3\u003e\u003cp\u003eThe display shows optical density and percentage transmission at the same time. A 2mm aperture provides a localized measurement area, while the 380–760nm response follows the CIE photopic luminosity function. Fine transmission resolution supports comparison of low-transmission samples.\u003c\/p\u003e\u003cp\u003eFAST mode takes approximately 1.1 seconds for samples below 5 OD. SLOW mode takes approximately 2.8 seconds for samples above 5 OD. HOLD freezes a result, and up to nine readings can be stored for review during an inspection.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/optical-density-meter-ls117-fixed-handheld-modes.jpg?v=1793770792\" alt=\"LS117 fixed holder and handheld measurement arrangements\" width=\"990\" height=\"616\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS117 fixed holder and handheld measurement arrangements\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eChoose a fixed or handheld arrangement\u003c\/h3\u003e\u003cp\u003eThe fixed holder maintains alignment for film and small samples. Handheld positioning accommodates larger diffusers and irregular parts when the two probes can be aligned on opposite sides. Start with an empty, aligned optical path and complete the warm-up and reference calibration before testing.\u003c\/p\u003e\u003cp\u003eControl strong ambient light and follow the prescribed calibration arrangement for the material being measured. High-transmission measurements require the black flannelette setup described in the operating instructions to reduce reflection effects. Four AAA batteries support portable operation.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOptical density range\u003c\/th\u003e\n\u003ctd\u003e0–6 OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOD accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.02 at 0–2 OD, ±1% at 2–4 OD, ±2% at 4–6 OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOD resolution\u003c\/th\u003e\n\u003ctd\u003e0.001 at 0–2 OD, 0.01 at 2–4 OD, 0.1 at 4–6 OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransmittance accuracy\u003c\/th\u003e\n\u003ctd\u003e±1% at 0–50%, ±2% at 50–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransmittance resolution\u003c\/th\u003e\n\u003ctd\u003e0.0005% at 0–10%, 0.005% at 10–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAperture\u003c\/th\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003e4 × AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHandheld dimensions\u003c\/th\u003e\n\u003ctd\u003e148 × 76 × 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument weight\u003c\/th\u003e\n\u003ctd\u003e576 g without batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68120163090475,"sku":"ELE-F8R3-01","price":965.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/optical-density-meter-ls117-film-holder-square-main-1200-v3.jpg?v=1793779967"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/collections\/light-transmittance-meter-ls116-front-glass-square-main-1200-v3.jpg?v=1793784882","url":"https:\/\/mcooh.com\/collections\/optical-transmission-density-meters.oembed","provider":"Mcooh","version":"1.0","type":"link"}