{"title":"UV Meters","description":"\u003cp\u003eChoose a UV power meter by its spectral response and the light source you need to measure. A meter built for one UV band or lamp type is not automatically suitable for another.\u003c\/p\u003e\n\u003ch2\u003ePower reading or accumulated energy?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eResult needed\u003c\/th\u003e\n\u003cth\u003eWhat to compare\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrradiance at the sensor\u003c\/td\u003e\n\u003ctd\u003eThe supported UV band and instantaneous reading, commonly expressed in units such as mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiant exposure during a process\u003c\/td\u003e\n\u003ctd\u003eWhether the model integrates irradiance over time and reports energy per area, such as mJ\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission or blocking comparison\u003c\/td\u003e\n\u003ctd\u003eWhether the meter and method support consistent before\/after measurements for the specific sample and source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eProduct starting points\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ls123-digital-uv-power-meter\"\u003eLS123 UV power meter\u003c\/a\u003e for its documented UV measurement and comparison functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ls137-uv-energy-meter\"\u003eLS137 UV energy meter\u003c\/a\u003e for its documented UVA LED application.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ls127c-uv-light-meter\"\u003eLS127C UVC radiometer\u003c\/a\u003e for its documented 254 nm lamp application.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck the exact model's response band, supported source, measurement range and recording method before comparing prices. These models address different tasks; they are not interchangeable substitutes.\u003c\/p\u003e\n\u003ch2\u003eBefore you select a meter\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIdentify the lamp or LED spectrum, not only its advertised wattage.\u003c\/li\u003e\n\u003cli\u003eCheck the sensor range against the expected irradiance at the measurement location.\u003c\/li\u003e\n\u003cli\u003eDecide whether you need a current value, accumulated exposure or a saved measurement record.\u003c\/li\u003e\n\u003cli\u003eKeep the measurement distance, orientation and process timing consistent with your procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA UV reading describes the measured light under the stated conditions. It does not, by itself, establish a process's curing quality or disinfection effectiveness.\u003c\/p\u003e","products":[{"product_id":"ls123-digital-uv-power-meter","title":"UV Power Meter LS123 for Solar Film and Glass Checks","description":"\u003cp\u003eThe Linshang LS123 UV power meter checks ultraviolet irradiance and the UV rejection of solar film or glass. Its 260–380 nm response peaks at 365 nm, with readings in μW\/cm² for sunlight and lower-intensity UV film demonstrations.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-power-meter-ls123-before-after.jpg?v=1793764939\" alt=\"LS123 illustration of readings before and after inserting film\" width=\"990\" height=\"552\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS123 illustration of readings before and after inserting film\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eEstablish a UV reference for film and glass checks\u003c\/h3\u003e\n\u003cp\u003ePlace the detector facing the UV source and record the incident irradiance with the optical path clear. Press 0% to set the rejection reference, then insert the sample between the source and the detector. Keep the source and meter fixed while taking the transmitted reading.\u003c\/p\u003e\n\u003cp\u003eThe display calculates UV rejection from the before-and-after irradiance ratio. Maintain the same source output, distance and alignment when comparing samples. A new source position requires a fresh reference before checking another film or pane.\u003c\/p\u003e\n\u003ch3\u003eLS123 UV measurement specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral response\u003c\/th\u003e\n\u003ctd\u003e260–380 nm; peak 365 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance range\u003c\/th\u003e\n\u003ctd\u003e0–40000 μW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy, H = reference value\u003c\/th\u003e\n\u003ctd\u003eH \u0026lt; 50 μW\/cm²: ±5 μW\/cm²; H ≥ 50 μW\/cm²: ±10%H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUV rejection display\u003c\/th\u003e\n\u003ctd\u003e-999% to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetector diameter\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e4 AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e125 x 69 x 24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApprox. 140 g including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-power-meter-ls123-rejection-display.jpg?v=1793764948\" alt=\"LS123 illustration identifying the UV rejection value\" width=\"990\" height=\"682\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS123 illustration identifying the UV rejection value\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eHold the displayed result\u003c\/h3\u003e\n\u003cp\u003ePress HOLD to retain a measurement for easier viewing, then release it to continue testing. The meter automatically powers off after thirty minutes without operation. Its handheld body suits sample demonstrations and repeated checks with a stable external source.\u003c\/p\u003e\n\u003ch3\u003eMatch the measurement to the response band\u003c\/h3\u003e\n\u003cp\u003eUse the LS123 within its stated irradiance range and 260–380 nm response. The reported rejection depends on both the material and the spectrum of the illumination. Keep those conditions with the result when comparing film or glass samples.\u003c\/p\u003e\n\u003cp\u003eFor consistent records, note the source, measuring position and material identity. Keep the 10 mm aperture clear and use the same detector orientation during each before-and-after comparison.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":41109450162219,"sku":"INS02-2151","price":147.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-power-meter-ls123-front-square-main-1200-v3.jpg?v=1793780000"},{"product_id":"ls136-uv-energy-meter","title":"Thin UV Energy Meter LS136 for Mercury Lamp Curing","description":"\u003cp\u003eThe Linshang LS136 thin UV energy meter measures irradiance, accumulated energy and temperature from high-pressure mercury and halogen lamps. Its 315–400 nm response peaks at 365 nm, and the 7.6 mm-thick metal body fits curing-machine measuring positions with limited clearance.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls136-measurement-display.jpg?v=1793765251\" alt=\"LS136 illustration comparing running and stopped measurement displays\" width=\"990\" height=\"720\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS136 illustration comparing running and stopped measurement displays\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eReview energy and peak values after the run\u003c\/h3\u003e\n\u003cp\u003eDuring measurement, the OLED shows accumulated energy, real-time irradiance, temperature and elapsed time. The stopped result provides energy together with maximum irradiance and maximum temperature. The latest completed test is retained after power-off and appears at the next startup.\u003c\/p\u003e\n\u003cp\u003eManual mode starts and stops from the meter controls. Automatic mode waits for the selected trigger irradiance and records during exposure until the signal falls below the threshold or the 32-minute period is reached. Choose the mode to match the curing process before placing the meter.\u003c\/p\u003e\n\u003ch3\u003eLS136 spectral and physical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral response\u003c\/th\u003e\n\u003ctd\u003e315–400 nm; peak 365 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance range\u003c\/th\u003e\n\u003ctd\u003e0–2000 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance accuracy, H = reference value\u003c\/th\u003e\n\u003ctd\u003eH \u0026lt; 5 mW\/cm²: ±0.5 mW\/cm²; H ≥ 5 mW\/cm²: ±10%H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnergy range\u003c\/th\u003e\n\u003ctd\u003e0–999999 mJ\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling speed\u003c\/th\u003e\n\u003ctd\u003e2048 samples\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecording period\u003c\/th\u003e\n\u003ctd\u003e32 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature measurement\u003c\/th\u003e\n\u003ctd\u003e-55°C to +125°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eRechargeable lithium battery, 3.7 V \/ 400 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 dot-matrix OLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e102 mm diameter x 7.6 mm thick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e136 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls136-thin-body.jpg?v=1793765262\" alt=\"LS136 side view illustrating its 7.6 mm thickness\" width=\"990\" height=\"694\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS136 side view illustrating its 7.6 mm thickness\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eRecharge and prepare the measuring position\u003c\/h3\u003e\n\u003cp\u003eThe built-in lithium battery charges through USB from a suitable 5 V supply. Face the sensor toward the UV source and keep the detector clean. The removable heat shield protects the display from close-range, high-power UV irradiation.\u003c\/p\u003e\n\u003cp\u003eThe 7.6 mm body dimension describes the instrument itself. Allow suitable clearance for the measuring arrangement and protective cover. The temperature channel reports process temperature over its listed measuring range.\u003c\/p\u003e\n\u003ch3\u003eKeep the test settings with each result\u003c\/h3\u003e\n\u003cp\u003eUse consistent placement and select the smoothing setting that matches the light-source power frequency. Record the lamp type, trigger mode, exposure time and instrument settings with the energy result. Store the meter in a dry environment to protect the sensor between measurements.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":41109469003819,"sku":"INS02-2152","price":304.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls136-front-square-main-1200-v3.jpg?v=1793780077"},{"product_id":"ls137-uv-energy-meter","title":"UV LED Energy Meter LS137 - 7.6 mm Rechargeable Disc","description":"\u003cp\u003eThe Linshang LS137 UV LED energy meter records irradiance, accumulated energy, temperature and exposure time in a thin disc body. Its 340–420 nm response is calibrated at 395 nm for measurements on suitable UV LED curing sources.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls137-thin-body.jpg?v=1793765357\" alt=\"LS137 illustration showing its 7.6 mm thickness\" width=\"990\" height=\"673\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS137 illustration showing its 7.6 mm thickness\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eFit a 7.6 mm instrument into the measuring setup\u003c\/h3\u003e\n\u003cp\u003eThe 102 mm-diameter metal body is 7.6 mm thick, with a compact OLED for reading real-time values and completed test results. Position the sensor toward the LED source and allow clearance for the instrument and the protective arrangement used in the machine.\u003c\/p\u003e\n\u003cp\u003eThe detector covers common UV LED wavelengths such as 365, 385, 395 and 405 nm. Use the same measuring position and settings for repeated checks, and record the LED wavelength with each result.\u003c\/p\u003e\n\u003ch3\u003eLS137 optical and recording specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral response\u003c\/th\u003e\n\u003ctd\u003e340–420 nm; calibrated at 395 nm UV LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance range\u003c\/th\u003e\n\u003ctd\u003e0–40000 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance resolution\u003c\/th\u003e\n\u003ctd\u003e1 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance accuracy, H = reference value\u003c\/th\u003e\n\u003ctd\u003eH \u0026lt; 50 mW\/cm²: ±5 mW\/cm²; H ≥ 50 mW\/cm²: ±10%H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnergy range\u003c\/th\u003e\n\u003ctd\u003e0–999999 mJ\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling speed\u003c\/th\u003e\n\u003ctd\u003e2048 samples\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecording period\u003c\/th\u003e\n\u003ctd\u003e32 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature measurement\u003c\/th\u003e\n\u003ctd\u003e-55°C to +125°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eRechargeable lithium battery, 3.7 V \/ 400 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 dot-matrix OLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e102 mm diameter x 7.6 mm thick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e136 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls137-measurement-display.jpg?v=1793765345\" alt=\"LS137 illustration of running and stopped measurement readings\" width=\"990\" height=\"719\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS137 illustration of running and stopped measurement readings\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eSelect automatic or manual exposure recording\u003c\/h3\u003e\n\u003cp\u003eManual mode starts and stops with the meter controls. In automatic mode, the instrument waits for the selected trigger level and records while exposure meets that condition. Recording ends when the signal drops below the trigger threshold or the 32-minute period is reached.\u003c\/p\u003e\n\u003cp\u003eDuring a run, the display shows energy, current irradiance, temperature and elapsed time. The stopped result includes accumulated energy, maximum irradiance and maximum temperature. The latest measurement stays available after the meter is switched off.\u003c\/p\u003e\n\u003ch3\u003eCharge and protect the instrument between runs\u003c\/h3\u003e\n\u003cp\u003eUSB charging supplies the built-in rechargeable lithium battery. Use the removable heat shield to protect the display during close-range exposure to high-power lamps. The temperature sensor measures the process within its stated range.\u003c\/p\u003e\n\u003cp\u003eKeep the optical aperture clean, choose smoothing to match the source power frequency and record the trigger settings with the result. Dry storage helps protect the UV sensor between measurement sessions.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":41109471068203,"sku":"INS02-2153","price":305.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls137-front-square-main-1200-v3.jpg?v=1793780087"},{"product_id":"ls120-uv-meter","title":"UV Energy Meter LS120 for Mercury and Halogen Curing Lamps","description":"\u003cp\u003eThe Linshang LS120 UV energy meter records irradiance, accumulated energy, temperature and exposure time for high-pressure mercury and halogen curing lamps. Its 315–400 nm response peaks at 365 nm, with a disc-shaped body for checking UV curing and exposure processes.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls120-process-curves.jpg?v=1793764730\" alt=\"LS120 illustration showing irradiance and temperature curves\" width=\"990\" height=\"826\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS120 illustration showing irradiance and temperature curves\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eReview a curing pass and its process curves\u003c\/h3\u003e\n\u003cp\u003eThe display presents real-time and maximum readings alongside accumulated energy. After a run, inspect the irradiance and temperature curves to see how the process changed during exposure. A 32-minute recording period supports a defined measurement run, and the latest test remains available after power-off.\u003c\/p\u003e\n\u003cp\u003eChoose manual start\/stop for a controlled test or automatic triggering for a conveyor pass. Automatic mode begins when the selected irradiance threshold is exceeded and ends when the irradiance falls below it or the recording period is reached. Set the mode before starting the run.\u003c\/p\u003e\n\u003ch3\u003eLS120 optical and recording specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral response\u003c\/th\u003e\n\u003ctd\u003e315–400 nm; peak 365 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance range\u003c\/th\u003e\n\u003ctd\u003e0–2000 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance accuracy, H = reference value\u003c\/th\u003e\n\u003ctd\u003eH \u0026lt; 5 mW\/cm²: ±0.5 mW\/cm²; H ≥ 5 mW\/cm²: ±10%H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnergy range\u003c\/th\u003e\n\u003ctd\u003e0–999999 mJ\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling speed\u003c\/th\u003e\n\u003ctd\u003e2048 samples\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecording period\u003c\/th\u003e\n\u003ctd\u003e32 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature measurement\u003c\/th\u003e\n\u003ctd\u003e-55°C to +125°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e2 AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e240 x 160 dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e120 mm diameter x 13 mm thick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls120-pc-reporting.jpg?v=1793764740\" alt=\"LS120 shown with Windows measurement reporting software\" width=\"990\" height=\"752\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS120 shown with Windows measurement reporting software\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eExport the completed measurement\u003c\/h3\u003e\n\u003cp\u003eConnect by USB to the Windows PC software after the run has stopped. The software reads recorded data, displays the irradiance and temperature curves, exports measurements and generates reports for process records. Keep the lamp type, measuring position and instrument settings with the exported results.\u003c\/p\u003e\n\u003ch3\u003ePosition the sensor for repeatable checks\u003c\/h3\u003e\n\u003cp\u003eThe sensing aperture is on the back of the meter and should face the UV source. Keep its surface clean and use the same measuring position for repeated process comparisons. Select smoothing to match the lamp’s power frequency when applicable.\u003c\/p\u003e\n\u003cp\u003eThe temperature channel measures the process over its specified range. Plan placement and handling around the instrument’s operating conditions, and store the meter dry between uses to protect the UV sensor.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":41112105779243,"sku":"INS02-2154","price":829.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls120-front-square-main-1200-v3.jpg?v=1793779979"},{"product_id":"ls128-uv-meter","title":"UV LED Energy Meter LS128 with Irradiance and Temperature Curves","description":"\u003cp\u003eThe Linshang LS128 UV LED energy meter measures irradiance, accumulated energy and temperature during LED curing. Its 340–420 nm spectral response is calibrated at 395 nm and supports checks on UV LED sources such as 365, 385, 395 and 405 nm lamps.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls128-process-curves.jpg?v=1793765153\" alt=\"LS128 illustration of irradiance and temperature curve review\" width=\"990\" height=\"721\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS128 illustration of irradiance and temperature curve review\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eCapture the UV LED exposure profile\u003c\/h3\u003e\n\u003cp\u003eThe current LS128 measuring range reaches 200000 mW\/cm² with 1 mW\/cm² resolution. A 32-minute run records the exposure while the display provides real-time and maximum values. Irradiance and temperature curves can be reviewed after measurement to examine changes through the process.\u003c\/p\u003e\n\u003cp\u003eUse manual mode to start and stop a test directly. Automatic mode waits for the selected irradiance threshold, records while the trigger condition is met and stops when the signal falls below the threshold or the recording period is reached. This helps align recording with the lamp exposure during conveyor checks.\u003c\/p\u003e\n\u003ch3\u003eLS128 spectral and recording data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral response\u003c\/th\u003e\n\u003ctd\u003e340–420 nm; calibrated at 395 nm UV LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance range\u003c\/th\u003e\n\u003ctd\u003e0–200000 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance resolution\u003c\/th\u003e\n\u003ctd\u003e1 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy for H ≥ 50 mW\/cm²\u003c\/th\u003e\n\u003ctd\u003e±10%H, where H is the reference value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnergy range\u003c\/th\u003e\n\u003ctd\u003e0–999999 mJ\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling speed\u003c\/th\u003e\n\u003ctd\u003e2048 samples\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecording period\u003c\/th\u003e\n\u003ctd\u003e32 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature measurement\u003c\/th\u003e\n\u003ctd\u003e-55°C to +125°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e2 AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e240 x 160 dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e120 mm diameter x 13 mm thick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls128-pc-reporting.jpg?v=1793765164\" alt=\"LS128 shown with Windows test report software\" width=\"990\" height=\"683\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS128 shown with Windows test report software\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eRead curves and export process records\u003c\/h3\u003e\n\u003cp\u003eConnect the USB interface to Windows PC software in the stopped state to read the recorded data. The software supports curve review, spreadsheet export and report generation. The latest measurement remains stored after the meter is switched off.\u003c\/p\u003e\n\u003cp\u003eRecord the LED wavelength, measuring position, trigger mode and relevant smoothing settings with the results. Using the same optical conditions makes repeat measurements easier to compare across curing runs.\u003c\/p\u003e\n\u003ch3\u003eOrient the detector toward the source\u003c\/h3\u003e\n\u003cp\u003eThe sensor is on the rear face of the disc. Keep the sensing area clean and place it consistently during each test. The separate temperature channel covers -55°C to +125°C; use the instrument within its operating conditions and store it in a dry environment between measurements.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":41112170037291,"sku":"INS02-2155","price":831.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-energy-meter-ls128-front-square-main-1200-v3.jpg?v=1793780056"},{"product_id":"ls127c-uv-light-meter","title":"UVC Light Meter LS127C for 254 nm Lamp Irradiance and Energy","description":"\u003cp\u003eThe Linshang LS127C integrated UVC light meter measures irradiance and accumulated UV energy from 254 nm low-pressure mercury lamps. Its built-in detector, statistical display and stored records support repeated lamp-output measurements at a defined position.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-light-meter-ls127c-display-statistics.jpg?v=1793765042\" alt=\"LS127C illustration identifying irradiance, energy and statistical values\" width=\"990\" height=\"739\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS127C illustration identifying irradiance, energy and statistical values\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eRead irradiance, dose and measurement statistics\u003c\/h3\u003e\n\u003cp\u003eThe display shows real-time irradiance with maximum, minimum and average values, elapsed measuring time and the optional accumulated-energy display. HOLD retains a result, while stored records allow the completed measurements to be reviewed later.\u003c\/p\u003e\n\u003cp\u003eAutomatic shutdown can be enabled with a selectable delay from 1 to 255 minutes. Measurement data is saved before shutdown, and the latest record is displayed at the next startup. Set the recording conditions and measuring units before beginning a series of lamp checks.\u003c\/p\u003e\n\u003ch3\u003eLS127C UVC specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral response\u003c\/th\u003e\n\u003ctd\u003e230–280 nm; peak 254 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance range\u003c\/th\u003e\n\u003ctd\u003e0–20000 μW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrradiance resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 μW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnergy range\u003c\/th\u003e\n\u003ctd\u003e0–9999999 μJ\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative indication error\u003c\/th\u003e\n\u003ctd\u003eH \u0026lt; 50 μW\/cm²: ±4 μW\/cm²; H ≥ 50 μW\/cm²: ±8%H, relative to NIM standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse time\u003c\/th\u003e\n\u003ctd\u003eLess than 0.5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecording time\u003c\/th\u003e\n\u003ctd\u003e0–99999 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay units\u003c\/th\u003e\n\u003ctd\u003eμW\/cm², mW\/cm² or W\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e2 AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e240 x 160 dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApprox. 232 g including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-light-meter-ls127c-pc-software.jpg?v=1793765051\" alt=\"LS127C Windows software shown on a laptop\" width=\"990\" height=\"682\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS127C Windows software shown on a laptop\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3\u003eReview records on a computer or by Bluetooth\u003c\/h3\u003e\n\u003cp\u003eThe USB interface connects to Windows software for reading records, exporting measurements and generating reports. Bluetooth monitoring uses a WeChat mini program with a Chinese interface. The specified wireless distance is up to 50 m in an open area, with the actual connection dependent on the surroundings.\u003c\/p\u003e\n\u003ch3\u003eKeep the detector position and lamp type consistent\u003c\/h3\u003e\n\u003cp\u003eThe one-metre hook supports positioning beneath a lamp for a defined-distance measurement. Use the same sensor orientation, lamp position and measuring settings for repeated checks. This instrument measures UVC output in its specified response band, so select it for the corresponding 254 nm mercury-lamp application.\u003c\/p\u003e\n\u003cp\u003eKeep the detector clean and store the meter dry between uses. Record the lamp identity, measuring distance, instrument settings and elapsed time with the results.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":41132227690539,"sku":"INS02-2158","price":465.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-light-meter-ls127c-front-square-main-1200-v3.jpg?v=1793780044"},{"product_id":"ultraviolet-radiation-detector-uv-meter","title":"Digital Ultraviolet Radiation Detector with Temperature Display – Portable UV Meter for Home and Outdoor Use","description":"\u003cp\u003eThe Digital Ultraviolet Radiation Detector with Temperature Display – Portable UV Meter for Home and Outdoor Use measures ultraviolet radiation for household and travel checks. This portable UV detector suits buyers who want to check UV from sunlight, indoor lighting, or UV lamps using an LCD readout.\u003c\/p\u003e\u003cp\u003eBefore choosing it as your UV reader, match the light source to the listed 350–380 nm band. The specifications do not establish coverage outside that band, so check compatibility with your intended source in the manual before ordering.\u003c\/p\u003e\n\u003ch2\u003eChoose the Configuration for Your Measurement\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement band:\u003c\/strong\u003e Check that the listed 350–380 nm band suits the UV source you intend to measure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange and readings:\u003c\/strong\u003e Review the detection range in the specifications and check the manual for how to interpret the displayed readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay and placement:\u003c\/strong\u003e The LCD display window is 2.2 inches, and a rear bracket supports placement during use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e The detector operates through a USB interface or two AAA batteries. Batteries are not included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Details and Specifications\u003c\/h2\u003e\n\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eStay protected from harmful UV rays with our Digital Ultraviolet Radiation Detector. This small, accurate, and portable UV meter provides real-time detection of ultraviolet radiation, ensuring you and your loved ones are safe. With a compact and lightweight design, it's easy to use and carry, making it an essential tool for both home and travel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable Design:\u003c\/strong\u003e Compact and lightweight for easy use and carry\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear LCD Display:\u003c\/strong\u003e Easily read measurements on the digital screen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Placement:\u003c\/strong\u003e Equipped with a bracket on the back for convenient placement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultifunctional:\u003c\/strong\u003e Ideal for daily household use and travel, detecting UV levels, providing early warnings, and measuring UV radiation doses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Application:\u003c\/strong\u003e Suitable for detecting UV radiation from sunlight, indoor lighting, UV lamps, and more\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Testing:\u003c\/strong\u003e Verify the effectiveness of UV-protection products like car films, curtains, protective clothing, glasses, and more\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Power Supply:\u003c\/strong\u003e Operates via USB interface or battery (not included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhether you're indoors or outdoors, our UV meter helps you stay aware of UV exposure, protecting you from potential harm. Ensure safety with this reliable and user-friendly device.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMaterial: ABS\u003cbr\u003eDisplay window: 2.2 inches\u003cbr\u003eWorking voltage: 5V\u003cbr\u003eBand: 350~380nano\u003cbr\u003ePower: 2 * AAA battery (not included)\u003cbr\u003eDetection error: less than 15%\u003cbr\u003eSampling speed: less than 3 seconds\u003cbr\u003eDetection ran-ge: 0-22 0-3000uw \/ c-m²\u003cbr\u003eStandby time: 2-3 hours\u003cbr\u003eDisplay type: digital display\u003cbr\u003eDisplay principle: LCD display\u003cbr\u003eDetection principle: lighting analysis and detection\u003cbr\u003eApplication technology: sen-sor technology application\u003cbr\u003eItem size: 127 * 54 * 18mm \/ 5.0 * 2.1 * 0.7in\u003cbr\u003eItem weight: 96g \/ 3.4ounce\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking List:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1 * Ultraviolet Radiation Detector\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 * User Manual\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eQuestions Before Ordering\u003c\/h2\u003e\n\u003ch3\u003eCan this UV detector check sunlight and indoor UV sources?\u003c\/h3\u003e\n\u003cp\u003eThe description lists sunlight, indoor lighting, and UV lamps as applications. Check that your intended source matches the listed 350–380 nm measurement band.\u003c\/p\u003e\n\u003ch3\u003eCan I use it to check UV-protection products?\u003c\/h3\u003e\n\u003cp\u003eThe description lists protective testing of car films, curtains, protective clothing, and glasses. Check the manual for the testing procedure and how to interpret the results.\u003c\/p\u003e\n\u003ch3\u003eWhat comes with the detector?\u003c\/h3\u003e\n\u003cp\u003eThe packing list includes the ultraviolet radiation detector and a user manual. AAA batteries are not included.\u003c\/p\u003e\n\u003ch3\u003eWhat is the temperature measurement range?\u003c\/h3\u003e\n\u003cp\u003eThe supplied description does not give a temperature measurement range or accuracy. Check the specifications or manual for those details before ordering.\u003c\/p\u003e\n\u003ch2\u003eSelection and Use Guides\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/uv-meter\"\u003eBrowse more UV Meters\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mcooh","offers":[{"title":"Default Title","offer_id":41132227952683,"sku":"INS02-3302","price":77.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/2186E5B68F1A1DA2.jpg?v=1720591690"},{"product_id":"uv-irradiance-meter-rgm-uvab","title":"RGM-UVA+B Meter – UV Irradiance Meter for Reptile Lamps Automotive Insulation Film","description":"\u003cdiv class=\"detailmodule_text\"\u003e\n\u003ch3 class=\"detail-desc-decorate-title\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp\u003eThe RGM-UVA+B Meter is a precision tool designed to measure the UVA and UVB irradiance of various UV lamps, ensuring optimal performance for a range of applications. Ideal for UV aging tests, reptile lamps, acrylic shield transmission, and eyewear UV block comparison, this meter provides accurate and reliable readings with an error margin of ±10% REF.NIST.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e Measures UVA and UVB irradiance with ±10% REF.NIST accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Applications:\u003c\/strong\u003e Suitable for UV aging, reptile lamps, acrylic shield transmission, and eyewear UV block comparison\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear Display:\u003c\/strong\u003e Equipped with an LCD that clearly shows the UVA and UVB irradiance values\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser-Friendly:\u003c\/strong\u003e Easy to operate, making it perfect for both professional and personal use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable Design:\u003c\/strong\u003e Compact and lightweight for convenience in various testing environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEnsure your UV lamps are performing optimally and providing the necessary irradiance for your specific needs with the RGM-UVA+B Meter.\u003c\/p\u003e\n\u003cp class=\"detail-desc-decorate-content\" data-spm-anchor-id=\"a2g0o.detail.1000023.i6.6a3bJ4blJ4blkV\"\u003e\u003cstrong\u003eapplications\u003c\/strong\u003e\u003cbr\u003eautomotive glass film, outdoor UV detection, low-intensity UV detection, sun lamp UV intensity detection\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Parameter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eModel : RGM-UVA B \u003cbr\u003eIrrad. Range : 0-1999 µW\/cm² UVA+B\u003cbr\u003ePeak Spectral Response : λp=370 nm\u003cbr\u003eResolution : 1 µW\/cm²\u003cbr\u003eConv. Rate : 3.0 Readings\/Sec\u003cbr\u003eDisplay : 3.5 Digit LCD\u003cbr\u003eDigit Size : 0.4 inch high\u003cbr\u003eOper. Temp : 32° F TO 90° F\u003cbr\u003eOper. Humid. : 5% TO 80% RH\u003cbr\u003eAccuracy : ±10% REF.NIST\u003cbr\u003eDimensions (in.) : 4.2L x 2.4W x 0.9D (in.)\u003cbr\u003eWeight : 4.5 OZ.\u003cbr\u003ePower Source : 2×1.5-Volt DC Battery(Batteries not included)\u003cbr\u003eLens : UV Glass\u003c\/p\u003e\n\u003ch3 class=\"detail-desc-decorate-title\" data-spm-anchor-id=\"a2g0o.detail.1000023.i4.6a3bJ4blJ4blkV\"\u003ePacking list\u003c\/h3\u003e\n\u003cp class=\"detail-desc-decorate-content\"\u003e1 x UVA B Meter\u003cbr\u003e1 x English manual\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"Default Title","offer_id":41132227985451,"sku":"INS02-3303","price":297.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/B63AD77DD174169D.jpg?v=1720591706"},{"product_id":"multi-probe-uv-light-meter-ls125","title":"Multi-Probe UV Light Meter LS125 with Selected UVA, UVB or UVC Probe","description":"\u003cp\u003eThe Linshang LS125 multi-probe UV light meter measures irradiance and accumulated energy using a detachable digital probe. Choose one of twelve probe kits for UVA, UVB, UVC or blue-light measurement. Each option supplies one LS125 main unit and one selected probe, with the probe response, aperture and measuring range matched to the light source being checked.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/multi-probe-uv-light-meter-ls125-probe-recognition.jpg?v=1793768831\" alt=\"LS125 recognizing the connected digital probe model\" width=\"990\" height=\"723\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS125 recognizing the connected digital probe model\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eChoose a probe for the light source\u003c\/h3\u003e\u003cp\u003eThe host recognizes the connected probe and adjusts its displayed units and measurement interface. A 1mm aperture is available for LED point sources through the UVALED-X1 option. The UVCWP-X1 option provides a waterproof probe for immersion to 1m, while the main unit stays dry.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVC-X0\u003c\/th\u003e\n\u003ctd\u003e230–280nm, 254nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVCWP-X1\u003c\/th\u003e\n\u003ctd\u003e230–280nm, 254nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVC-X2\u003c\/th\u003e\n\u003ctd\u003e210–250nm, 222nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVCLED-X0\u003c\/th\u003e\n\u003ctd\u003e230–315nm, for 260–285nm LEDs. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVB-X0\u003c\/th\u003e\n\u003ctd\u003e280–315nm, 310nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVA-X0\u003c\/th\u003e\n\u003ctd\u003e315–400nm, 365nm peak. 0–2000 mW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVA-X1\u003c\/th\u003e\n\u003ctd\u003e315–400nm, 365nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVA-X2\u003c\/th\u003e\n\u003ctd\u003e315–365nm, 340nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVALED-X0\u003c\/th\u003e\n\u003ctd\u003e340–420nm, calibrated at 395nm. 0–200000 mW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVALED-X1\u003c\/th\u003e\n\u003ctd\u003e340–420nm, calibrated at 395nm. 0–200000 mW\/cm². 1mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVALED-X3\u003c\/th\u003e\n\u003ctd\u003e340–420nm, calibrated at 395nm. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBL-X0\u003c\/th\u003e\n\u003ctd\u003e410–490nm, calibrated at 450nm. 0–2000 mW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIrradiance, energy and response\u003c\/h3\u003e\u003cp\u003eThe LCD displays real-time, maximum, minimum and average irradiance alongside duration and accumulated energy. UVA-X0, UVALED-X0, UVALED-X1 and BL-X0 sample at 2048 readings per second. The other listed probes sample at six readings per second.\u003c\/p\u003e\u003cp\u003eFor μW-range probes, accuracy is ±5μW\/cm² below 50μW\/cm² and ±10%H at or above that level. UVA-X0 uses ±0.5mW\/cm² below 5mW\/cm² and ±10%H at or above it. UVALED-X0, UVALED-X1 and BL-X0 use ±5mW\/cm² below 50mW\/cm² and ±10%H at or above it. H is the reference irradiance.\u003c\/p\u003e\u003ch3\u003eHost specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e240 x 160 dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFour AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHost dimensions \/ weight\u003c\/th\u003e\n\u003ctd\u003e148 x 76 x 26mm \/ approx. 194g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProbe connection\u003c\/th\u003e\n\u003ctd\u003ePush-pull locking connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy range\u003c\/th\u003e\n\u003ctd\u003e0–9999999μJ\/cm² for μW-range probes, or 0–9999999mJ\/cm² for mW-range probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuration range\u003c\/th\u003e\n\u003ctd\u003e0–99999s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecords\u003c\/th\u003e\n\u003ctd\u003eNine saved measurement records, read on the host display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/multi-probe-uv-light-meter-ls125-irradiance-energy-statistics.jpg?v=1793768841\" alt=\"LS125 display identifying irradiance, energy, duration and statistics\" width=\"990\" height=\"689\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS125 display identifying irradiance, energy, duration and statistics\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eMeasurement records and handling\u003c\/h3\u003e\u003cp\u003eUse HOLD to retain a completed reading and review saved records on the instrument. Select smoothing to suit AC-powered sources when using a high-speed probe. Keep the sensing surface clean and protect it from humidity during storage. UVCLED-X0 measurements require control of strong ambient light because of the probe's wider spectral response. Position the probe with appropriate UV exposure controls in place before energizing the source.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"LS125 + UVC-X0","offer_id":68120014585899,"sku":"UVM-F6R8-01","price":739.51,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVCWP-X1","offer_id":68120014618667,"sku":"UVM-F6R8-02","price":767.39,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVC-X2","offer_id":68120014651435,"sku":"UVM-F6R8-03","price":793.68,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVCLED-X0","offer_id":68120014684203,"sku":"UVM-F6R8-04","price":768.98,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVB-X0","offer_id":68120014716971,"sku":"UVM-F6R8-05","price":742.68,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVA-X0","offer_id":68120014749739,"sku":"UVM-F6R8-06","price":719.52,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVA-X1","offer_id":68120014782507,"sku":"UVM-F6R8-07","price":744.28,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVA-X2","offer_id":68120014815275,"sku":"UVM-F6R8-08","price":721.02,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVALED-X0","offer_id":68120014848043,"sku":"UVM-F6R8-09","price":745.88,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVALED-X1","offer_id":68120014880811,"sku":"UVM-F6R8-10","price":722.53,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVALED-X3","offer_id":68120014913579,"sku":"UVM-F6R8-11","price":712.12,"currency_code":"USD","in_stock":true},{"title":"LS125 + BL-X0","offer_id":68120014946347,"sku":"UVM-F6R8-12","price":734.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/multi-probe-uv-light-meter-ls125-host-uvc-probe-square-main-1200-v3.jpg?v=1793780013"},{"product_id":"touchscreen-uv-light-meter-ls135","title":"Touchscreen UV Light Meter LS135 with Interchangeable Probe Kits","description":"\u003cp\u003eView a live irradiance curve alongside energy and statistical readings on the Linshang LS135 touchscreen UV light meter. Its 3.5-inch IPS display supports configurable measurement views, and the host recognizes the interchangeable digital probe. Select a kit containing one main unit and one probe for the wavelength band and intensity range required by your application.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/touchscreen-uv-light-meter-ls135-power-curve.jpg?v=1793768906\" alt=\"LS135 touchscreen showing a real-time UV irradiance curve\" width=\"990\" height=\"772\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS135 touchscreen showing a real-time UV irradiance curve\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eMatch the probe to the source\u003c\/h3\u003e\u003cp\u003eTwelve probe choices cover UVA, UVB, UVC and blue-light sources. The selected aperture matters for small light spots, while the spectral response should match the lamp or LED being measured. UVCWP-X1 is the waterproof probe option, rated for immersion to 1m. Keep the host outside the water.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVC-X0\u003c\/th\u003e\n\u003ctd\u003e230–280nm, 254nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVCWP-X1\u003c\/th\u003e\n\u003ctd\u003e230–280nm, 254nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVC-X2\u003c\/th\u003e\n\u003ctd\u003e210–250nm, 222nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVCLED-X0\u003c\/th\u003e\n\u003ctd\u003e230–315nm, for 260–285nm LEDs. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVB-X0\u003c\/th\u003e\n\u003ctd\u003e280–315nm, 310nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVA-X0\u003c\/th\u003e\n\u003ctd\u003e315–400nm, 365nm peak. 0–2000 mW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVA-X1\u003c\/th\u003e\n\u003ctd\u003e315–400nm, 365nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVA-X2\u003c\/th\u003e\n\u003ctd\u003e315–365nm, 340nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVALED-X0\u003c\/th\u003e\n\u003ctd\u003e340–420nm, calibrated at 395nm. 0–200000 mW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVALED-X1\u003c\/th\u003e\n\u003ctd\u003e340–420nm, calibrated at 395nm. 0–200000 mW\/cm². 1mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVALED-X3\u003c\/th\u003e\n\u003ctd\u003e340–420nm, calibrated at 395nm. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBL-X0\u003c\/th\u003e\n\u003ctd\u003e410–490nm, calibrated at 450nm. 0–2000 mW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMeasurement performance\u003c\/h3\u003e\u003cp\u003eReal-time, maximum, minimum and average irradiance appear with measurement duration, accumulated energy and uniformity. High-speed UVA-X0, UVALED-X0, UVALED-X1 and BL-X0 probes sample at 2048 readings per second. The remaining probe options sample at six readings per second.\u003c\/p\u003e\u003cp\u003eFor μW-range probes, accuracy is ±5μW\/cm² below 50μW\/cm² and ±10%H at or above that level. UVA-X0 uses ±0.5mW\/cm² below 5mW\/cm² and ±10%H at or above it. UVALED-X0, UVALED-X1 and BL-X0 use ±5mW\/cm² below 50mW\/cm² and ±10%H at or above it. H is the reference irradiance.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/touchscreen-uv-light-meter-ls135-windows-software.jpg?v=1793768913\" alt=\"LS135 connected to Windows software for measurement data review\" width=\"990\" height=\"724\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS135 connected to Windows software for measurement data review\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRecords, export and remote viewing\u003c\/h3\u003e\u003cp\u003eSave and name up to 1000 measurement records from the touchscreen. A USB connection to Windows software supports record retrieval, curve display, Excel export and printed reports. Bluetooth also supports remote measurement viewing through a WeChat mini-program.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHost display\u003c\/th\u003e\n\u003ctd\u003e3.5-inch IPS touchscreen, 480 x 320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e3.7V, 4000mAh rechargeable lithium-ion battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB power input\u003c\/th\u003e\n\u003ctd\u003eDC 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHost dimensions \/ weight\u003c\/th\u003e\n\u003ctd\u003e141 x 70.4 x 22mm \/ approx. 277g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy range\u003c\/th\u003e\n\u003ctd\u003e0–9999999μJ\/cm² for μW-range probes, or 0–9999999mJ\/cm² for mW-range probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuration range\u003c\/th\u003e\n\u003ctd\u003e0–99999s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProbe connection\u003c\/th\u003e\n\u003ctd\u003ePush-pull locking connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eSet smoothing to match the source's AC supply when using a high-speed probe. Control strong ambient light for UVCLED-X0 readings and keep all optical surfaces clean. Establish the probe position and appropriate UV shielding before turning on the light source.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"LS135 + UVC-X0","offer_id":68120016093227,"sku":"UVM-C7P5-01","price":745.88,"currency_code":"USD","in_stock":true},{"title":"LS135 + UVCWP-X1","offer_id":68120016125995,"sku":"UVM-C7P5-02","price":773.8,"currency_code":"USD","in_stock":true},{"title":"LS135 + UVC-X2","offer_id":68120016158763,"sku":"UVM-C7P5-03","price":797.1,"currency_code":"USD","in_stock":true},{"title":"LS135 + UVCLED-X0","offer_id":68120016191531,"sku":"UVM-C7P5-04","price":772.19,"currency_code":"USD","in_stock":true},{"title":"LS135 + UVB-X0","offer_id":68120016224299,"sku":"UVM-C7P5-05","price":749.11,"currency_code":"USD","in_stock":true},{"title":"LS135 + UVA-X0","offer_id":68120016257067,"sku":"UVM-C7P5-06","price":725.56,"currency_code":"USD","in_stock":true},{"title":"LS135 + UVA-X1","offer_id":68120016289835,"sku":"UVM-C7P5-07","price":747.49,"currency_code":"USD","in_stock":true},{"title":"LS135 + UVA-X2","offer_id":68120016322603,"sku":"UVM-C7P5-08","price":724.04,"currency_code":"USD","in_stock":true},{"title":"LS135 + UVALED-X0","offer_id":68120016355371,"sku":"UVM-C7P5-09","price":739.51,"currency_code":"USD","in_stock":true},{"title":"LS135 + UVALED-X1","offer_id":68120016388139,"sku":"UVM-C7P5-10","price":716.54,"currency_code":"USD","in_stock":true},{"title":"LS135 + UVALED-X3","offer_id":68120016420907,"sku":"UVM-C7P5-11","price":707.75,"currency_code":"USD","in_stock":true},{"title":"LS135 + BL-X0","offer_id":68120016453675,"sku":"UVM-C7P5-12","price":730.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/touchscreen-uv-light-meter-ls135-stand-probe-square-main-1200-v3.jpg?v=1793780067"},{"product_id":"narrow-probe-uv-led-meter-ls126a","title":"UV LED Light Meter LS126A with 7.2mm Narrow Probe","description":"\u003cp\u003eThe Linshang LS126A UV LED light meter measures irradiance and accumulated energy where a conventional round probe is difficult to place. Its separate sensor is 7.2mm wide with a 3mm test aperture, providing access to narrow measurement positions in curing and exposure equipment. The spectral response covers 340–420nm, with calibration referenced to a 395nm UV LED source.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-led-light-meter-ls126a-probe-dimensions.jpg?v=1793769168\" alt=\"LS126A probe dimensions showing 7.2mm width and 3mm sensing aperture\" width=\"990\" height=\"691\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS126A probe dimensions showing 7.2mm width and 3mm sensing aperture\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eFit the probe into a narrow measurement position\u003c\/h3\u003e\u003cp\u003eThe probe measures 36 x 7.2 x 4.7mm and connects to the handheld unit through a 0.8m cable. Position the aperture toward the light source and keep its orientation and distance consistent across comparisons. Typical source wavelengths include 365, 375, 385, 395 and 405nm within the specified response band.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-led-light-meter-ls126a-measurement-statistics.jpg?v=1793769179\" alt=\"LS126A screen identifying irradiance, energy, time and statistics\" width=\"990\" height=\"747\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS126A screen identifying irradiance, energy, time and statistics\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eIrradiance and accumulated energy\u003c\/h3\u003e\u003cp\u003eA 2048-readings-per-second sampling rate supports measurement of changing light output. The instrument displays real-time, maximum, minimum and average irradiance, measurement duration and accumulated energy. Select smoothing for 50Hz or 60Hz AC-powered light sources, or switch smoothing off for a suitable DC source.\u003c\/p\u003e\u003cp\u003eHOLD retains the displayed result and saves the measurement record. The instrument keeps nine records, with the most recent accessible first. Auto-off can be enabled to shut down after ten minutes without operation.\u003c\/p\u003e\u003ch3\u003eDetails and specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS126A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpectral response\u003c\/th\u003e\n\u003ctd\u003e340–420nm, calibrated at 395nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIrradiance range\u003c\/th\u003e\n\u003ctd\u003e0–20000mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e1mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003eBelow 50mW\/cm², ±5mW\/cm². At or above 50mW\/cm², ±10%H. H is reference irradiance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy \/ duration range\u003c\/th\u003e\n\u003ctd\u003e0–9999999mJ\/cm² \/ 0–99999s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSampling speed\u003c\/th\u003e\n\u003ctd\u003e2048 readings\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest aperture\u003c\/th\u003e\n\u003ctd\u003e3mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay \/ batteries\u003c\/th\u003e\n\u003ctd\u003e240 x 160 LCD \/ four AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHost size \/ instrument weight\u003c\/th\u003e\n\u003ctd\u003e170 x 76 x 26mm \/ approx. 232g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eHandling between checks\u003c\/h3\u003e\u003cp\u003eKeep the photosensitive opening clean and store the instrument in a dry environment. Arrange the sensor and cable before energizing the UV source, using the exposure controls required for the equipment. Record the source wavelength, position and selected units with the reading to make later comparisons consistent.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68120017207339,"sku":"UVM-M8D3-01","price":790.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uv-led-light-meter-ls126a-front-narrow-probe-square-main-1200-v3.jpg?v=1793780025"},{"product_id":"uvc-254nm-light-meter-ls126c","title":"254nm UVC Light Meter LS126C with Recording and USB Export","description":"\u003cp\u003eThe Linshang LS126C 254nm UVC light meter records irradiance and accumulated energy from low-pressure mercury lamps. Its external sensor responds over 230–280nm with a 254nm peak reference. The supplied one-meter test hook helps position the sensor for lamp checks, while the handheld unit stores time-based measurements for later review.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uvc-light-meter-ls126c-recording-display.jpg?v=1793769237\" alt=\"LS126C display identifying irradiance, energy, duration and clock\" width=\"990\" height=\"750\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS126C display identifying irradiance, energy, duration and clock\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRecord changes over time\u003c\/h3\u003e\u003cp\u003eSelect a storage interval of 1, 10 or 60 seconds for a recording period of 10, 100 or 600 minutes when automatic shutdown is disabled. A record holds up to 600 sampled values, replacing the oldest values when that limit is reached. The instrument retains up to 25 records.\u003c\/p\u003e\u003cp\u003eWith timed shutdown enabled, the recording interval is fixed at one second and the shutdown time can be selected from one to ten minutes. Real-time, maximum, minimum and average irradiance appear with duration, a real-time clock and accumulated energy when enabled.\u003c\/p\u003e\u003ch3\u003eLS126C specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpectral response\u003c\/th\u003e\n\u003ctd\u003e230–280nm, 254nm peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIrradiance range \/ resolution\u003c\/th\u003e\n\u003ctd\u003e0–20000μW\/cm² \/ 0.1μW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative indication error\u003c\/th\u003e\n\u003ctd\u003eBelow 50μW\/cm², ±4μW\/cm². At or above 50μW\/cm², ±8%H relative to NIM reference. H is reference irradiance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy range\u003c\/th\u003e\n\u003ctd\u003e0–9999999μJ\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResponse time\u003c\/th\u003e\n\u003ctd\u003eLess than 0.5s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensor aperture \/ cable\u003c\/th\u003e\n\u003ctd\u003e10mm diameter \/ 1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay \/ batteries\u003c\/th\u003e\n\u003ctd\u003e240 x 160 LCD \/ four AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHost dimensions \/ instrument weight\u003c\/th\u003e\n\u003ctd\u003e148 x 76 x 26mm \/ approx. 300g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uvc-light-meter-ls126c-pc-export.jpg?v=1793769249\" alt=\"LS126C connected to PC software for data export and reports\" width=\"990\" height=\"697\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS126C connected to PC software for data export and reports\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eExport and lamp-check setup\u003c\/h3\u003e\u003cp\u003eConnect by USB to the dedicated PC software to read stored records, display irradiance curves, export measurements to Excel and prepare printed reports. HOLD keeps a current reading visible for recording and review.\u003c\/p\u003e\u003cp\u003eSet up the hook and sensor while the UV source is off, then follow the lamp's measurement procedure and appropriate exposure controls. Use the required distance and orientation consistently between checks. Keep the sensor clean and dry, and protect the photosensitive surface during storage. This meter's spectral response is suited to the specified mercury-lamp application.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68120018255915,"sku":"UVM-V9H6-01","price":668.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/uvc-light-meter-ls126c-front-probe-square-main-1200-v3.jpg?v=1793780035"},{"product_id":"four-band-uv-energy-meter-ls138","title":"Four-Band UV Energy Meter LS138 for UVA, UVB, UVC and UVV","description":"\u003cp\u003eCapture four spectral bands during a curing check with the Linshang LS138 four-band UV energy meter. The disc-shaped instrument records irradiance and accumulated energy for UVA, UVB, UVC and UVV, together with temperature and exposure duration. It suits process checks on UV curing, coating, exposure and printing equipment where the band-by-band result matters.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/four-band-uv-energy-meter-ls138-energy-temperature-readings.jpg?v=1793769308\" alt=\"LS138 display showing separate band energy, irradiance and temperature\" width=\"990\" height=\"779\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS138 display showing separate band energy, irradiance and temperature\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eFour spectral bands in one run\u003c\/h3\u003e\u003cp\u003eSelect one to four measurement bands before starting. Each band has its own response range and peak reference. The display presents band results, irradiance curves and a temperature curve so changes during the run can be reviewed together.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVC\u003c\/th\u003e\n\u003ctd\u003e230–280nm, 254nm peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVB\u003c\/th\u003e\n\u003ctd\u003e280–315nm, 310nm peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVA\u003c\/th\u003e\n\u003ctd\u003e315–400nm, 365nm peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVV\u003c\/th\u003e\n\u003ctd\u003e395–445nm, 420nm peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIrradiance range \/ resolution\u003c\/th\u003e\n\u003ctd\u003e0–2000mW\/cm² \/ 0.01mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy range\u003c\/th\u003e\n\u003ctd\u003e0–999999mJ\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003eBelow 5mW\/cm², ±0.5mW\/cm². At or above 5mW\/cm², ±10%H with ±5% typical. H is reference irradiance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature measurement range\u003c\/th\u003e\n\u003ctd\u003e-55 to +125 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument operating range\u003c\/th\u003e\n\u003ctd\u003e0–100 degrees C, non-condensing conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSampling \/ stored data\u003c\/th\u003e\n\u003ctd\u003e2048 samples\/s \/ irradiance 32 readings\/s and temperature 2 readings\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecording duration\u003c\/th\u003e\n\u003ctd\u003eUp to 32 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay \/ power\u003c\/th\u003e\n\u003ctd\u003e240 x 160 LCD \/ two AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions \/ net weight\u003c\/th\u003e\n\u003ctd\u003e120mm diameter x 13mm thick \/ 225g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/four-band-uv-energy-meter-ls138-windows-reports.jpg?v=1793769316\" alt=\"LS138 connected to PC software for curves and reports\" width=\"990\" height=\"780\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS138 connected to PC software for curves and reports\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRecording modes and Windows reports\u003c\/h3\u003e\u003cp\u003eManual mode starts and stops a measurement through the instrument controls. Automatic mode waits for its trigger conditions, which helps when a conveyor must travel before reaching the lamp. A run ends at the selected stopping condition or the 32-minute recording limit.\u003c\/p\u003e\u003cp\u003eThe USB connection supports Windows software for reading stored data, reviewing each band's irradiance curve and the temperature curve, exporting measurements to Excel and generating reports. Keep the band selection, smoothing and measurement position consistent when comparing runs.\u003c\/p\u003e\u003ch3\u003eSensor care and positioning\u003c\/h3\u003e\u003cp\u003eThe optical sensors are on the back of the instrument and should face the source at the intended test location. Keep them clean and protect them from humidity during storage. The temperature sensor's displayed range is distinct from the instrument's operating conditions, so check the equipment environment before placing the meter in a process line.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68120018976811,"sku":"UVM-J5T8-01","price":1343.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/four-band-uv-energy-meter-ls138-front-readings-square-main-1200-v3.jpg?v=1793780097"},{"product_id":"ndt-uv-visible-light-meter-ls331","title":"NDT Light Meter LS331 for UV Irradiance, Illuminance and CCT","description":"\u003cp\u003eThe Linshang LS331 NDT light meter measures UV irradiance, visible illuminance and correlated color temperature together. It supports viewing-condition checks for fluorescent penetrant and magnetic-particle inspection work. The separate optical head can be placed at the measurement position while the handheld unit displays the readings.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/ndt-light-meter-ls331-simultaneous-readings.jpg?v=1793769370\" alt=\"LS331 simultaneous UV, illuminance and color-temperature display\" width=\"990\" height=\"675\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS331 simultaneous UV, illuminance and color-temperature display\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRead UV and visible-light conditions together\u003c\/h3\u003e\u003cp\u003eA UV detector with a 365nm peak reference covers a 315–405nm response band. Visible illuminance is measured with a spectral sensor using the photopic response, and the screen also displays correlated color temperature. These outputs help document the lighting conditions at the inspection area.\u003c\/p\u003e\u003cp\u003eMaximum UV and illuminance values are retained for review alongside the real-time readings. HOLD freezes the current display, and stored measurements can be retrieved on the instrument. USB connects to dedicated PC software for record reading and Excel export.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/ndt-light-meter-ls331-measurement-ranges.jpg?v=1793769379\" alt=\"LS331 display and labeled UV and visible-light measuring ranges\" width=\"990\" height=\"696\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS331 display and labeled UV and visible-light measuring ranges\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eMeasurement details\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUV response\u003c\/th\u003e\n\u003ctd\u003e315–405nm, 365nm peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUV irradiance range \/ resolution\u003c\/th\u003e\n\u003ctd\u003e0–200000μW\/cm² \/ 0.1μW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUV accuracy\u003c\/th\u003e\n\u003ctd\u003eBelow 50μW\/cm², ±5μW\/cm². At or above 50μW\/cm², ±10%H. H is reference irradiance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIlluminance range \/ resolution\u003c\/th\u003e\n\u003ctd\u003e0–1000000lux \/ 0.1lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIlluminance accuracy\u003c\/th\u003e\n\u003ctd\u003e≤±(4%H + 2lux), calibrated under CIE standard A. H is reference illuminance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIlluminance units\u003c\/th\u003e\n\u003ctd\u003eLux and foot-candles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCCT range\u003c\/th\u003e\n\u003ctd\u003e1000–100000K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResponse time\u003c\/th\u003e\n\u003ctd\u003eLess than 0.7s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest aperture\u003c\/th\u003e\n\u003ctd\u003e21mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay \/ power\u003c\/th\u003e\n\u003ctd\u003e240 x 160 LCD \/ two AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument weight\u003c\/th\u003e\n\u003ctd\u003eApprox. 232g including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSet up a consistent lighting check\u003c\/h3\u003e\u003cp\u003ePosition the sensor at the inspection location and keep its orientation consistent between readings. Record the source arrangement and selected units with the measurement so repeat checks use the same conditions. Appropriate UV exposure controls remain part of the inspection setup.\u003c\/p\u003e\u003cp\u003eChoose an automatic shutdown setting that suits the measurement session, and keep the optical surface clean. Store the probe in a dry place between uses to protect its humidity-sensitive optical components. The meter's separate UV and visible readings allow each lighting quantity to be assessed against the inspection procedure being used.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68120019828779,"sku":"UVM-P6G9-01","price":832.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/ndt-light-meter-ls331-front-sensor-square-main-1200-v3.jpg?v=1793781166"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/collections\/LS120UVMeter.jpg?v=1783058858","url":"https:\/\/mcooh.com\/collections\/uv-meter.oembed?page=2","provider":"Mcooh","version":"1.0","type":"link"}