{"product_id":"ammonia-gas-detector-mh2000-nh3","title":"Ammonia Gas Detector with Pump - NH3 Range Options","description":"\u003cp\u003eChoose an ammonia detector around the required NH3 range and sensor configuration. The MH2000-NH3 uses an internal sampling pump to draw a gas sample to its electrochemical sensor. Standard options cover six ranges from 0-100 to 0-5000 ppm; the High Precision configuration uses a CITY sensor and offers separate 0-50, 0-100 and 0-1000 ppm versions. Select the configuration and range together when ordering. Each option is one detector with its selected measuring span.\u003c\/p\u003e\n\u003ch3\u003eChoose the Sensor Configuration and Range\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eAvailable measuring ranges\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e0-100 \/ 200 \/ 500 \/ 1000 \/ 2000 \/ 5000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Precision (CITY)\u003c\/td\u003e\n\u003ctd\u003e0-50 \/ 100 \/ 1000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eBoth configurations measure ammonia. A 0-100 ppm Standard option and a 0-100 ppm High Precision option are different sensor configurations, even though they share a measuring span. Choose the span for the expected concentration and measurement task; the maximum available range is not the range of every instrument. The configuration selector shows the combinations available to order.\u003c\/p\u003e\n\u003ch3\u003ePump Sampling and On-Instrument Controls\u003c\/h3\u003e\n\u003cp\u003eThe pump provides up to 1 L\/min flow with ten adjustment settings. The LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available, with ppm and mg\/m³ concentration displays. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup.\u003c\/p\u003e\n\u003cp\u003eTwo alarm stages have adjustable setpoints. Sound, light and vibration provide different alert outputs, including an 85 dB sound alarm and blue low-alarm\/red high-alarm indicators. Use the supplied instructions and the measurement procedure for setup and operation.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMH2000-NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetected gas\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor configurations\u003c\/td\u003e\n\u003ctd\u003eStandard; High Precision (CITY sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard ranges\u003c\/td\u003e\n\u003ctd\u003e0-100, 0-200, 0-500, 0-1000, 0-2000 and 0-5000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Precision ranges\u003c\/td\u003e\n\u003ctd\u003e0-50, 0-100 and 0-1000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling method\u003c\/td\u003e\n\u003ctd\u003eInternal sampling pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump adjustment\u003c\/td\u003e\n\u003ctd\u003e10 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD dot matrix; gas type, concentration, unit, battery level and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating languages\u003c\/td\u003e\n\u003ctd\u003eEnglish and Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration units\u003c\/td\u003e\n\u003ctd\u003eppm \/ mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm outputs\u003c\/td\u003e\n\u003ctd\u003eSound, light and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm stages\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm setpoints\u003c\/td\u003e\n\u003ctd\u003eUser adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound alarm\u003c\/td\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm lights\u003c\/td\u003e\n\u003ctd\u003eBlue for low alarm; red for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement compensation\u003c\/td\u003e\n\u003ctd\u003eTemperature and pressure compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument controls\u003c\/td\u003e\n\u003ctd\u003eSelf-check, zero calibration and factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.6 V, 2300 mAh rechargeable lithium polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4-6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 75 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument weight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording \/ PC export\u003c\/td\u003e\n\u003ctd\u003eOptional; excluded from the High Precision base options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecording Options and Supplied Instrument\u003c\/h3\u003e\n\u003cp\u003eData logging and PC export are optional and are not included in these High Precision base options. If measurement records are required, ask about the recording configuration before ordering. Optional sampling filters, drying accessories and high-temperature probes are separate choices; their appearance in a product gallery does not establish that they are included with every option.\u003c\/p\u003e\n\u003cp\u003eThe instrument weighs 300 g and has a rechargeable lithium-polymer battery. Gallery images illustrate the shared instrument housing, including views with a carrying case. An image showing several views of the detector does not represent a multi-detector order. For use, follow the instructions supplied with the selected NH3 instrument.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"Standard \/ 0-100ppm","offer_id":41114327384107,"sku":"INS03-8064","price":711.32,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-200ppm","offer_id":41114327416875,"sku":"INS03-8065","price":712.78,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-500ppm","offer_id":41114327449643,"sku":"INS03-8066","price":802.83,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-1000ppm","offer_id":41114327482411,"sku":"INS03-8067","price":804.49,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-2000ppm","offer_id":41114327515179,"sku":"INS03-8068","price":1141.08,"currency_code":"USD","in_stock":true},{"title":"Standard \/ 0-5000ppm","offer_id":41114327547947,"sku":"INS03-8069","price":1143.45,"currency_code":"USD","in_stock":true},{"title":"High Precision (CITY) \/ 0-50ppm","offer_id":67815677820971,"sku":"GAS-A8M4-07","price":1257.83,"currency_code":"USD","in_stock":true},{"title":"High Precision (CITY) \/ 0-100ppm","offer_id":67815677853739,"sku":"GAS-A8M4-08","price":1301.21,"currency_code":"USD","in_stock":true},{"title":"High Precision (CITY) \/ 0-1000ppm","offer_id":67815677886507,"sku":"GAS-A8M4-09","price":1244.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/D5CA7BBF2D3805C2.jpg?v=1716948431","url":"https:\/\/mcooh.com\/products\/ammonia-gas-detector-mh2000-nh3","provider":"Mcooh","version":"1.0","type":"link"}