{"product_id":"digital-glass-thickness-meter-ls201","title":"Digital Glass Thickness Meter LS201 for Double and Triple Glazing","description":"\u003cp\u003eThe Linshang LS201 digital glass thickness meter displays glass-layer and air-gap readings from one side of a glazing unit. Laser reflection and CCD detection support checks on double glazing, triple glazing and laminated assemblies. The digital readout helps document pane and cavity dimensions when access to the glass edge is limited.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/digital-glass-thickness-meter-ls201-layer-identification.jpg?v=1793767557\" alt=\"LS201 digital display identifying glass layers and air spaces\" width=\"990\" height=\"688\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS201 digital display identifying glass layers and air spaces\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRead the glazing structure\u003c\/h3\u003e\u003cp\u003eThe meter covers glass thickness up to 70mm and air-space thickness up to 45mm. For a triple-glazed unit, its display can identify three glass layers and two intervening air spaces. The stated measurement accuracy is ±(0.1mm + 1%H), where H is the reference thickness.\u003c\/p\u003e\u003cp\u003eFor laminated glass, the laminate interlayer cannot be measured independently. Its thickness is included in an adjacent glass value, and the instrument may show a combined glass result when it cannot resolve the internal interface. Account for this behavior when interpreting a laminated assembly.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/digital-glass-thickness-meter-ls201-manual-mode.jpg?v=1793767573\" alt=\"LS201 manual mode for setting layer types and estimated thickness\" width=\"990\" height=\"754\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS201 manual mode for setting layer types and estimated thickness\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eAutomatic and manual measurement\u003c\/h3\u003e\u003cp\u003eAutomatic mode can present several possible layer results for review. Select the result that matches the sample structure. Manual mode lets the operator enter layer types and estimated thicknesses when the automatic results do not fit the glazing. Keep the expected glass arrangement available when checking a complex unit.\u003c\/p\u003e\u003ch3\u003eDetails and specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement principle\u003c\/th\u003e\n\u003ctd\u003eLaser reflection with CCD detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGlass \/ air-space range\u003c\/th\u003e\n\u003ctd\u003eUp to 70mm \/ up to 45mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement accuracy\u003c\/th\u003e\n\u003ctd\u003e±(0.1mm + 1%H), H is reference thickness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModes\u003c\/th\u003e\n\u003ctd\u003eAutomatic and manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e240 x 160 dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum measurement area\u003c\/th\u003e\n\u003ctd\u003e5 x 50mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFour alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e130 x 72 x 33mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e330g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003ePreparing an installed-window check\u003c\/h3\u003e\u003cp\u003ePlace the back of the instrument closely against a clean glass surface. Strong direct sunlight, dirt, scratches or a highly reflective low-E layer can prevent layer identification. Where appropriate, change the accessible measurement surface and review the result against the known assembly.\u003c\/p\u003e\u003cp\u003eKeep the detector clean and avoid looking into the rear laser outlet. Check that people on the other side of the glass are clear of the beam before taking a reading. English and Chinese interface settings are available.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68119903731755,"sku":"THK-L9T5-01","price":841.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/digital-glass-thickness-meter-ls201-front-display-square-main-1200-v3.jpg?v=1793780684","url":"https:\/\/mcooh.com\/products\/digital-glass-thickness-meter-ls201","provider":"Mcooh","version":"1.0","type":"link"}