{"product_id":"multi-probe-uv-light-meter-ls125","title":"Multi-Probe UV Light Meter LS125 with Selected UVA, UVB or UVC Probe","description":"\u003cp\u003eThe Linshang LS125 multi-probe UV light meter measures irradiance and accumulated energy using a detachable digital probe. Choose one of twelve probe kits for UVA, UVB, UVC or blue-light measurement. Each option supplies one LS125 main unit and one selected probe, with the probe response, aperture and measuring range matched to the light source being checked.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/multi-probe-uv-light-meter-ls125-probe-recognition.jpg?v=1793768831\" alt=\"LS125 recognizing the connected digital probe model\" width=\"990\" height=\"723\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS125 recognizing the connected digital probe model\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eChoose a probe for the light source\u003c\/h3\u003e\u003cp\u003eThe host recognizes the connected probe and adjusts its displayed units and measurement interface. A 1mm aperture is available for LED point sources through the UVALED-X1 option. The UVCWP-X1 option provides a waterproof probe for immersion to 1m, while the main unit stays dry.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVC-X0\u003c\/th\u003e\n\u003ctd\u003e230–280nm, 254nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVCWP-X1\u003c\/th\u003e\n\u003ctd\u003e230–280nm, 254nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVC-X2\u003c\/th\u003e\n\u003ctd\u003e210–250nm, 222nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVCLED-X0\u003c\/th\u003e\n\u003ctd\u003e230–315nm, for 260–285nm LEDs. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVB-X0\u003c\/th\u003e\n\u003ctd\u003e280–315nm, 310nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVA-X0\u003c\/th\u003e\n\u003ctd\u003e315–400nm, 365nm peak. 0–2000 mW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVA-X1\u003c\/th\u003e\n\u003ctd\u003e315–400nm, 365nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVA-X2\u003c\/th\u003e\n\u003ctd\u003e315–365nm, 340nm peak. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVALED-X0\u003c\/th\u003e\n\u003ctd\u003e340–420nm, calibrated at 395nm. 0–200000 mW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVALED-X1\u003c\/th\u003e\n\u003ctd\u003e340–420nm, calibrated at 395nm. 0–200000 mW\/cm². 1mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUVALED-X3\u003c\/th\u003e\n\u003ctd\u003e340–420nm, calibrated at 395nm. 0–200000 μW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBL-X0\u003c\/th\u003e\n\u003ctd\u003e410–490nm, calibrated at 450nm. 0–2000 mW\/cm². 10mm aperture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIrradiance, energy and response\u003c\/h3\u003e\u003cp\u003eThe LCD displays real-time, maximum, minimum and average irradiance alongside duration and accumulated energy. UVA-X0, UVALED-X0, UVALED-X1 and BL-X0 sample at 2048 readings per second. The other listed probes sample at six readings per second.\u003c\/p\u003e\u003cp\u003eFor μW-range probes, accuracy is ±5μW\/cm² below 50μW\/cm² and ±10%H at or above that level. UVA-X0 uses ±0.5mW\/cm² below 5mW\/cm² and ±10%H at or above it. UVALED-X0, UVALED-X1 and BL-X0 use ±5mW\/cm² below 50mW\/cm² and ±10%H at or above it. H is the reference irradiance.\u003c\/p\u003e\u003ch3\u003eHost specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e240 x 160 dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFour AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHost dimensions \/ weight\u003c\/th\u003e\n\u003ctd\u003e148 x 76 x 26mm \/ approx. 194g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProbe connection\u003c\/th\u003e\n\u003ctd\u003ePush-pull locking connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy range\u003c\/th\u003e\n\u003ctd\u003e0–9999999μJ\/cm² for μW-range probes, or 0–9999999mJ\/cm² for mW-range probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuration range\u003c\/th\u003e\n\u003ctd\u003e0–99999s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecords\u003c\/th\u003e\n\u003ctd\u003eNine saved measurement records, read on the host display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/multi-probe-uv-light-meter-ls125-irradiance-energy-statistics.jpg?v=1793768841\" alt=\"LS125 display identifying irradiance, energy, duration and statistics\" width=\"990\" height=\"689\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS125 display identifying irradiance, energy, duration and statistics\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eMeasurement records and handling\u003c\/h3\u003e\u003cp\u003eUse HOLD to retain a completed reading and review saved records on the instrument. Select smoothing to suit AC-powered sources when using a high-speed probe. Keep the sensing surface clean and protect it from humidity during storage. UVCLED-X0 measurements require control of strong ambient light because of the probe's wider spectral response. Position the probe with appropriate UV exposure controls in place before energizing the source.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"LS125 + UVC-X0","offer_id":68120014585899,"sku":"UVM-F6R8-01","price":739.51,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVCWP-X1","offer_id":68120014618667,"sku":"UVM-F6R8-02","price":767.39,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVC-X2","offer_id":68120014651435,"sku":"UVM-F6R8-03","price":793.68,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVCLED-X0","offer_id":68120014684203,"sku":"UVM-F6R8-04","price":768.98,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVB-X0","offer_id":68120014716971,"sku":"UVM-F6R8-05","price":742.68,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVA-X0","offer_id":68120014749739,"sku":"UVM-F6R8-06","price":719.52,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVA-X1","offer_id":68120014782507,"sku":"UVM-F6R8-07","price":744.28,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVA-X2","offer_id":68120014815275,"sku":"UVM-F6R8-08","price":721.02,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVALED-X0","offer_id":68120014848043,"sku":"UVM-F6R8-09","price":745.88,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVALED-X1","offer_id":68120014880811,"sku":"UVM-F6R8-10","price":722.53,"currency_code":"USD","in_stock":true},{"title":"LS125 + UVALED-X3","offer_id":68120014913579,"sku":"UVM-F6R8-11","price":712.12,"currency_code":"USD","in_stock":true},{"title":"LS125 + BL-X0","offer_id":68120014946347,"sku":"UVM-F6R8-12","price":734.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/multi-probe-uv-light-meter-ls125-host-uvc-probe-square-main-1200-v3.jpg?v=1793780013","url":"https:\/\/mcooh.com\/products\/multi-probe-uv-light-meter-ls125","provider":"Mcooh","version":"1.0","type":"link"}