{"product_id":"ndt-uv-visible-light-meter-ls331","title":"NDT Light Meter LS331 for UV Irradiance, Illuminance and CCT","description":"\u003cp\u003eThe Linshang LS331 NDT light meter measures UV irradiance, visible illuminance and correlated color temperature together. It supports viewing-condition checks for fluorescent penetrant and magnetic-particle inspection work. The separate optical head can be placed at the measurement position while the handheld unit displays the readings.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/ndt-light-meter-ls331-simultaneous-readings.jpg?v=1793769370\" alt=\"LS331 simultaneous UV, illuminance and color-temperature display\" width=\"990\" height=\"675\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS331 simultaneous UV, illuminance and color-temperature display\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eRead UV and visible-light conditions together\u003c\/h3\u003e\u003cp\u003eA UV detector with a 365nm peak reference covers a 315–405nm response band. Visible illuminance is measured with a spectral sensor using the photopic response, and the screen also displays correlated color temperature. These outputs help document the lighting conditions at the inspection area.\u003c\/p\u003e\u003cp\u003eMaximum UV and illuminance values are retained for review alongside the real-time readings. HOLD freezes the current display, and stored measurements can be retrieved on the instrument. USB connects to dedicated PC software for record reading and Excel export.\u003c\/p\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/ndt-light-meter-ls331-measurement-ranges.jpg?v=1793769379\" alt=\"LS331 display and labeled UV and visible-light measuring ranges\" width=\"990\" height=\"696\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003cfigcaption\u003eLS331 display and labeled UV and visible-light measuring ranges\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3\u003eMeasurement details\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLinshang LS331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUV response\u003c\/th\u003e\n\u003ctd\u003e315–405nm, 365nm peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUV irradiance range \/ resolution\u003c\/th\u003e\n\u003ctd\u003e0–200000μW\/cm² \/ 0.1μW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUV accuracy\u003c\/th\u003e\n\u003ctd\u003eBelow 50μW\/cm², ±5μW\/cm². At or above 50μW\/cm², ±10%H. H is reference irradiance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIlluminance range \/ resolution\u003c\/th\u003e\n\u003ctd\u003e0–1000000lux \/ 0.1lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIlluminance accuracy\u003c\/th\u003e\n\u003ctd\u003e≤±(4%H + 2lux), calibrated under CIE standard A. H is reference illuminance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIlluminance units\u003c\/th\u003e\n\u003ctd\u003eLux and foot-candles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCCT range\u003c\/th\u003e\n\u003ctd\u003e1000–100000K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResponse time\u003c\/th\u003e\n\u003ctd\u003eLess than 0.7s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest aperture\u003c\/th\u003e\n\u003ctd\u003e21mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay \/ power\u003c\/th\u003e\n\u003ctd\u003e240 x 160 LCD \/ two AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument weight\u003c\/th\u003e\n\u003ctd\u003eApprox. 232g including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSet up a consistent lighting check\u003c\/h3\u003e\u003cp\u003ePosition the sensor at the inspection location and keep its orientation consistent between readings. Record the source arrangement and selected units with the measurement so repeat checks use the same conditions. Appropriate UV exposure controls remain part of the inspection setup.\u003c\/p\u003e\u003cp\u003eChoose an automatic shutdown setting that suits the measurement session, and keep the optical surface clean. Store the probe in a dry place between uses to protect its humidity-sensitive optical components. The meter's separate UV and visible readings allow each lighting quantity to be assessed against the inspection procedure being used.\u003c\/p\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":68120019828779,"sku":"UVM-P6G9-01","price":832.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/ndt-light-meter-ls331-front-sensor-square-main-1200-v3.jpg?v=1793781166","url":"https:\/\/mcooh.com\/products\/ndt-uv-visible-light-meter-ls331","provider":"Mcooh","version":"1.0","type":"link"}