{"product_id":"oxygen-detector-mh2000-o2","title":"Handheld Pump Oxygen Meter, Oxygen level detector for Concentration and Air Quality Detection","description":"\u003ch2\u003eChoose a Pump-Sampling Oxygen Range\u003c\/h2\u003e\n\u003cp\u003eThe MH2000-O2 listing is an oxygen-concentration instrument with internal pump sampling. Compare the oxygen-range option and record-handling requirements for the job. The different spans in the table are range choices to clarify for the supplied unit, not a claim that every unit covers every span.\u003c\/p\u003e\n\u003ch3\u003eListed Purchase Options\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0-25%Vol\u003c\/td\u003e\n\u003ctd\u003eINS03-8089\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0-30%Vol\u003c\/td\u003e\n\u003ctd\u003eINS03-8090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0-50%Vol\u003c\/td\u003e\n\u003ctd\u003eINS03-8091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0-100%Vol\u003c\/td\u003e\n\u003ctd\u003eINS03-8092\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eSelect one listed option. Different ranges or pump configurations are separate supplied versions; they are not all combined in one unit.\u003c\/p\u003e\n\u003ch3\u003eQuestions That Help You Choose\u003c\/h3\u003e\n\u003ch4\u003eWhich O2 range will the supplied unit use?\u003c\/h4\u003e\n\u003cp\u003eSpecify the concentration span needed and confirm the corresponding supplied configuration; do not treat the full list as one combined range.\u003c\/p\u003e\n\u003ch4\u003eDoes the task require an internal pump?\u003c\/h4\u003e\n\u003cp\u003eThis listing describes a built-in pump. Compare the diffusion-based MH-1200H-S-O2 if that arrangement fits the measurement plan.\u003c\/p\u003e\n\u003ch4\u003eWill I need measurement records?\u003c\/h4\u003e\n\u003cp\u003eCompare the listed logging and USB download with the records required for the work.\u003c\/p\u003e\n\u003cp\u003eFor the buying comparison, read \u003ca href=\"\/blogs\/gas-detector\/pumped-vs-diffusion-gas-detector\"\u003epump vs. diffusion selection\u003c\/a\u003e and \u003ca href=\"\/blogs\/gas-detector\/single-gas-vs-multi-gas-detector\"\u003esingle-gas vs. multi-gas comparison\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eCompare \u003ca href=\"\/products\/oxygen-gas-detector-yt-1200h-s-o2\"\u003ediffusion O2 option\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eCompare a Single-Option O2 Listing\u003c\/h3\u003e\u003cp\u003eThe \u003ca href=\"\/products\/portable-o2-gas-detector-k100a\"\u003eK-100A oxygen listing\u003c\/a\u003e presents one O2 purchase option. This MH2000 page offers separate oxygen-range variants and identifies an internal pump. Compare the required span and sampling arrangement; the K-100A page does not identify an internal pump.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDescription\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Handheld Pump Oxygen Detector is an advanced O2 gas detector designed for accurate oxygen concentration detection in various environments. This air quality detector features a fast response time of ≤30s, thanks to its internal sampling pump and high-precision sensors from world-renowned brands, approved by third-party testing organizations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features include:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe oxygen monitor is fast-responding, highly accurate and comes with a built-in sampling pump.\u003c\/li\u003e\n\u003cli\u003eSwitchable gas concentration units (PPM and mg\/m3) with a single press.\u003c\/li\u003e\n\u003cli\u003eSelf-calibration and zero calibration functions for improved accuracy and reliability.\u003c\/li\u003e\n\u003cli\u003eEasy restoration to factory settings with one press to avoid mis-operations.\u003c\/li\u003e\n\u003cli\u003eOxygen meter has multi-mode alarms, including light, sound and vibration, and can set alarm points to enhance user safety.\u003c\/li\u003e\n\u003cli\u003eExtensive data logging capability with storage for over 100,000 sets of data, quickly accessible on the detector.\u003c\/li\u003e\n\u003cli\u003eHigh-speed USB data transmission for efficient downloading to PC.\u003c\/li\u003e\n\u003cli\u003eLong-lasting lithium polymer rechargeable battery providing 14 hours of continuous operation for toxic gases and 10 hours for combustible gases.\u003c\/li\u003e\n\u003cli\u003eDurable high-intensity engineering plastic housing, suitable for various conditions and environments, with IP65 protection making it water-proof, dust-proof, and explosion-proof.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis detector is ideal for use in farms, livestock areas, liquid ammonia plants, public toilets, septic tanks, and other industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable width=\"878\" style=\"height: 470.251px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003eSampling\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003eWith internal sampling pump, flow rate is up to 1L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 39.1875px;\"\u003eData logging\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 39.1875px;\"\u003eData logging with adjustable interval, and available for data downloading to PC through USB cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003eGas\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003eOxygen O2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003eMeasure Range\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003e0-25%vol, 0-30%vol, 0-50%vol, 0-100%VOL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003e0.01%vol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003ePrecision\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003e≤±2%F.S. (higher precision is available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003eResponse Time\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003e≤10S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003eZero shift\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003e≤±1%（F.S.\/year）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 39.1875px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 39.1875px;\"\u003eLCD dot matrix display, with display of gas type, real time gas concentration, battery power, time, gas unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003eTemperature\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003e-20℃～50℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003e0-95%RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003eExplosion-Proof\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003eExibⅡCT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 39.1875px;\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 39.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.375px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 78.375px;\"\u003eAlarm\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 78.375px;\"\u003eSound: 85dB\u003cbr\u003eLight: LED, low alarm: blue, high alarm: red\u003cbr\u003eVibration: the detector will vibrate when powered on\u003cbr\u003eAlarm point is settable according to customer requirement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 39.1875px;\"\u003eBattery\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 39.1875px;\"\u003e3.6V 2300mAh lithium polymer rechargeable battery, operate time is about 12h continuously, charging time: 4-6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003e205x75x32mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"149\" style=\"height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd width=\"563\" style=\"height: 19.5938px;\"\u003e300g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eContinue Your Oxygen Detector Comparison\u003c\/h2\u003e\n\u003cp\u003eFor the MH2000-O2, compare the internal pump and the selected oxygen range with the measurement task. Read the \u003ca href=\"\/blogs\/gas-detector\/oxygen-detector-for-confined-spaces\"\u003eoxygen detector selection guide\u003c\/a\u003e to compare the measurement questions before choosing a model. A guide or product listing does not determine suitability for a site procedure.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-25%Vol","offer_id":41124699570219,"sku":"INS03-8089","price":593.27,"currency_code":"USD","in_stock":true},{"title":"0-30%Vol","offer_id":41124699602987,"sku":"INS03-8090","price":581.14,"currency_code":"USD","in_stock":true},{"title":"0-50%Vol","offer_id":41124699635755,"sku":"INS03-8091","price":1086.77,"currency_code":"USD","in_stock":true},{"title":"0-100%Vol","offer_id":41124699668523,"sku":"INS03-8092","price":1089.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/A5797BD0E06364CE.jpg?v=1716951858","url":"https:\/\/mcooh.com\/products\/oxygen-detector-mh2000-o2","provider":"Mcooh","version":"1.0","type":"link"}