{"product_id":"portable-chlorine-gas-detector-mh-1200h-s-cl2","title":"Portable Chlorine (Cl2) Detector with Diffusion Sampling","description":"\u003cp\u003eThe MH-1200H-S-CL2 is a portable chlorine (Cl2) gas detector for site checks that call for a concentration reading at the instrument. Its electrochemical sensor measures surrounding air by diffusion, and the rear clip and protective cover support carrying the detector during inspection rounds. Choose the required CL2 range when ordering; each range is a separate instrument configuration.\u003c\/p\u003e\u003ch3\u003eChoose a Chlorine Range\u003c\/h3\u003e\u003cp\u003eThe four available measurement spans are 0-10, 0-20, 0-50, and 0-100 ppm. Select the range that matches your monitoring procedure and expected concentration span. The standard instrument uses diffusion sampling. An external sampling pump is an optional setup for tasks that require a different sampling arrangement; confirm that configuration before ordering.\u003c\/p\u003e\u003ch3\u003eDisplay and Alarm Review\u003c\/h3\u003e\u003cp\u003eThe monochrome dot-matrix LCD displays the concentration and supports ppm and mg\/m³ units. Backlight timing can be adjusted, and the light can activate automatically during an alarm. Audible, visual, and vibration alerts provide three ways to notice an alarm; the audible alarm is rated at 85 dB. Alarm thresholds are configurable, and the instrument can retain 100 alarm records for review on its display. Zero and self-calibration functions are available.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eMH-1200H-S-CL2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured gas\u003c\/th\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor principle\u003c\/th\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling method\u003c\/th\u003e\n\u003ctd\u003eDiffusion; external pump setup optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange configurations\u003c\/th\u003e\n\u003ctd\u003e0-10 ppm; 0-20 ppm; 0-50 ppm; 0-100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e128 x 64 monochrome dot-matrix LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConcentration units\u003c\/th\u003e\n\u003ctd\u003eppm and mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm modes\u003c\/th\u003e\n\u003ctd\u003eSound, light, and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAudible alarm\u003c\/th\u003e\n\u003ctd\u003e85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm history\u003c\/th\u003e\n\u003ctd\u003e100 records, viewable on the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight\u003c\/th\u003e\n\u003ctd\u003eAdjustable timing; automatic activation during an alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e2300 mAh rechargeable lithium-polymer battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 Degree C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e131 x 83 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate unit weight\u003c\/th\u003e\n\u003ctd\u003e240 g with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eUse and Configuration Notes\u003c\/h3\u003e\u003cp\u003eFor diffusion sampling, surrounding air must reach the sensor openings. Follow the supplied instructions and your site's procedures for calibration, alarm settings, and gas-monitoring checks. The product photographs show the shared housing used across this model family; gas names on the demonstration screen may differ from the ordered CL2 configuration.\u003c\/p\u003e","brand":"Mcooh","offers":[{"title":"0-10 ppm","offer_id":67594439393323,"sku":"GAS-Q9C4-01","price":587.47,"currency_code":"USD","in_stock":true},{"title":"0-20 ppm","offer_id":67594439426091,"sku":"GAS-Q9C4-02","price":587.47,"currency_code":"USD","in_stock":true},{"title":"0-50 ppm","offer_id":67594439458859,"sku":"GAS-Q9C4-03","price":597.94,"currency_code":"USD","in_stock":true},{"title":"0-100 ppm","offer_id":67594439491627,"sku":"GAS-Q9C4-04","price":597.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/portable-chlorine-gas-detector-front.jpg?v=1790746848","url":"https:\/\/mcooh.com\/products\/portable-chlorine-gas-detector-mh-1200h-s-cl2","provider":"Mcooh","version":"1.0","type":"link"}