{"product_id":"testkey-high-isolation-temperature-logger-tk4700h","title":"High-Isolation Temperature Logger TK4700H - 8 to 32 Inputs","description":"\u003cp\u003eThe Testkey TK4700H high-isolation temperature logger provides 8, 16, 24 or 32 installed thermocouple channels. Channel-to-channel isolation is specified at 1500 V DC peak-to-peak.\u003c\/p\u003e\n\u003cp\u003eSelect the installed channel count required by the test. The 10 ms acquisition figure applies to 48-channel operation with curve and bar-graph display disabled.\u003c\/p\u003e\n\u003ch3\u003eModel comparison and specifications\u003c\/h3\u003e\n\u003cdiv class=\"spec-table\" role=\"region\" aria-label=\"TK4708H, TK4716H, TK4724H, TK4732H specifications\" tabindex=\"0\" style=\"max-width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:660px;border-collapse:collapse;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#edf3f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;white-space:nowrap;\"\u003eTK4708H\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;white-space:nowrap;\"\u003eTK4716H\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;white-space:nowrap;\"\u003eTK4724H\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;white-space:nowrap;\"\u003eTK4732H\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eIncluded measurement channels\u003c\/th\u003e\n\u003ctd style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e16\u003c\/td\u003e\n\u003ctd style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e24\u003c\/td\u003e\n\u003ctd style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eThermocouple inputs\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eJ, K, T, E, S, N, B and R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eThermocouple temperature range\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e−200–1800 °C, depending on thermocouple type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eTemperature resolution\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e0.01 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eBasic thermocouple measurement accuracy\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e±0.2% ±2 digits, excluding thermocouple accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eFast acquisition\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e10 ms for 48 channels, with curve and bar-graph display disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eChannel isolation\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e1500 V DC peak-to-peak between channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eSupplied temperature probes\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eK-type thermocouples configured for the ordered model, 2 m each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003ePlatform capacity with optional modules\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e48 channels, installed channels follow the selected model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003ePer-channel temperature alarms\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eIndependent upper and lower limits, out-of-limit readings change color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eStandard interfaces\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eRS232, USB HOST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eCommunication protocols\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eSCPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e4.3-inch 480 x 272 color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eInput power\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eAC 100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eSpecification environment\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e15–35 °C, \u0026lt;80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eOverall dimensions (W x H x D)\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e258 x 110 x 300 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eNet weight\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e2.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eTemperature accuracy excludes the thermocouple probe accuracy.\u003c\/p\u003e\n\u003cp\u003eThe usable temperature range depends on the connected thermocouple type.\u003c\/p\u003e\n\u003cp\u003eChassis reference dimensions are 213 × 87 × 270 mm (W × H × D).\u003c\/p\u003e\n\u003cp\u003eAdditional channel modules are available separately. A custom 6000 V DC channel-isolation configuration is available.\u003c\/p\u003e\n\u003ch3\u003eIncluded equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelected TK4700H series instrument\u003c\/li\u003e\n\u003cli\u003eK-type thermocouples configured for the ordered model, 2 m per probe\u003c\/li\u003e\n\u003cli\u003e8 GB USB flash drive\u003c\/li\u003e\n\u003cli\u003eCommunication cable\u003c\/li\u003e\n\u003cli\u003eData acquisition software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct photographs show the TK4724H configuration. The selected model determines the supplied electrical specification and channel configuration.\u003c\/p\u003e\n\u003cp\u003eBrowse \u003ca href=\"\/collections\/temperature-data-loggers\"\u003eTemperature \u0026amp; Data Loggers\u003c\/a\u003e to compare related instruments.\u003c\/p\u003e","brand":"Testkey","offers":[{"title":"TK4708H","offer_id":68243234684971,"sku":"ELE-EE58-01","price":1580.95,"currency_code":"USD","in_stock":true},{"title":"TK4716H","offer_id":68243234717739,"sku":"ELE-EE58-02","price":2266.33,"currency_code":"USD","in_stock":true},{"title":"TK4724H","offer_id":68243234750507,"sku":"ELE-EE58-03","price":2817.08,"currency_code":"USD","in_stock":true},{"title":"TK4732H","offer_id":68243234783275,"sku":"ELE-EE58-04","price":3543.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/high-isolation-temperature-logger-tk4700h-main.jpg?v=1794413387","url":"https:\/\/mcooh.com\/products\/testkey-high-isolation-temperature-logger-tk4700h","provider":"Mcooh","version":"1.0","type":"link"}