{"product_id":"testkey-multichannel-temperature-logger-tk5000","title":"Multichannel Temperature Logger TK5000 - 7-Inch Display","description":"\u003cp\u003eThe Testkey TK5000 temperature logger provides 8, 16, 24 or 32 installed thermocouple channels with a 7-inch color display and selectable acquisition speeds.\u003c\/p\u003e\n\u003cp\u003eChoose the installed thermocouple channel count required by the test. Standard acquisition takes 1 s or 500 ms for 64 channels.\u003c\/p\u003e\n\u003ch3\u003eModel comparison and specifications\u003c\/h3\u003e\n\u003cdiv class=\"spec-table\" role=\"region\" aria-label=\"TK5008, TK5016, TK5024, TK5032 specifications\" tabindex=\"0\" style=\"max-width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:660px;border-collapse:collapse;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#edf3f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;white-space:nowrap;\"\u003eTK5008\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;white-space:nowrap;\"\u003eTK5016\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;white-space:nowrap;\"\u003eTK5024\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;white-space:nowrap;\"\u003eTK5032\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eIncluded measurement channels\u003c\/th\u003e\n\u003ctd style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e16\u003c\/td\u003e\n\u003ctd style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e24\u003c\/td\u003e\n\u003ctd style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eThermocouple inputs\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eJ, K, T, E, S, N, B and R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eThermocouple temperature range\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e−200–1800 °C, depending on thermocouple type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eTemperature resolution\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e0.01 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eBasic thermocouple measurement accuracy\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e±0.2% ±2 digits, excluding thermocouple accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eStandard acquisition time for 64 channels\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eSlow 1 s, fast 500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eChannel isolation\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e350 V DC peak-to-peak between channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eSupplied temperature probes\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eK-type thermocouples configured for the ordered model, 2 m each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eMain-unit platform capacity with optional modules\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e128 channels, installed channels follow the selected model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eMaximum expanded capacity\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e256 channels with optional expansion equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003ePer-channel temperature alarms\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eIndependent upper and lower limits, out-of-limit readings change color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eStandard interfaces\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eRS232, USB HOST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eCommunication protocols\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eSCPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e7-inch 480 x 272 color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eInput power\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003eAC 100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eSpecification environment\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e15–35 °C, \u0026lt;80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;position:sticky;left:0;background:#f7f9fa;min-width:145px;\"\u003eNet weight\u003c\/th\u003e\n\u003ctd colspan=\"4\" style=\"padding:8px 10px;text-align:left;vertical-align:top;border:1px solid #dce0e5;\"\u003e3.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eTemperature accuracy excludes the thermocouple probe accuracy.\u003c\/p\u003e\n\u003cp\u003eThe usable temperature range depends on the connected thermocouple type.\u003c\/p\u003e\n\u003cp\u003eChassis reference dimensions are 240 × 140 × 253 mm (W × H × D).\u003c\/p\u003e\n\u003cp\u003eAdditional channel modules, external expansion equipment, 100 ms acquisition and a rechargeable battery are available separately.\u003c\/p\u003e\n\u003ch3\u003eIncluded equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelected TK5000 series instrument\u003c\/li\u003e\n\u003cli\u003eK-type thermocouples configured for the ordered model, 2 m per probe\u003c\/li\u003e\n\u003cli\u003e8 GB USB flash drive\u003c\/li\u003e\n\u003cli\u003eCommunication cable\u003c\/li\u003e\n\u003cli\u003eData acquisition software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct photographs show the TK5000 series configuration. The selected model determines the supplied electrical specification and channel configuration.\u003c\/p\u003e\n\u003cp\u003eBrowse \u003ca href=\"\/collections\/temperature-data-loggers\"\u003eTemperature \u0026amp; Data Loggers\u003c\/a\u003e to compare related instruments.\u003c\/p\u003e","brand":"Testkey","offers":[{"title":"TK5008","offer_id":68243234947115,"sku":"ELE-009D-01","price":1437.12,"currency_code":"USD","in_stock":true},{"title":"TK5016","offer_id":68243234979883,"sku":"ELE-009D-02","price":1704.11,"currency_code":"USD","in_stock":true},{"title":"TK5024","offer_id":68243235012651,"sku":"ELE-009D-03","price":2086.07,"currency_code":"USD","in_stock":true},{"title":"TK5032","offer_id":68243235045419,"sku":"ELE-009D-04","price":2333.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/2133\/5851\/files\/multichannel-temperature-logger-tk5000-main.jpg?v=1794413443","url":"https:\/\/mcooh.com\/products\/testkey-multichannel-temperature-logger-tk5000","provider":"Mcooh","version":"1.0","type":"link"}