Pulse Frequency Collection and Processing Module for Hall Flow Sensors with Modbus RUT RS485 Protocol, 4 Inputs

SKU: INS04-FM0135
Vendor
mcooh
Regular price
$96.22
Sale price
$96.22
Regular price
$0
Sold out
Unit price
Quantity must be 1 or more

Description

The Mod X4 Pulse Frequency Collection and Processing Module is designed for accurate water flow measurement and control using Hall effect flow sensors. This module supports the Modbus RUT RS485 communication protocol and offers four input channels for comprehensive data collection and processing. Ideal for industrial applications where precise flow measurement and control are essential.

Features:

  • Modbus RUT RS485 Communication Protocol: Ensures reliable and accurate data transmission and control.
  • Four Input Channels: Allows for multiple flow sensors to be connected simultaneously for enhanced data collection.
  • Configurable Parameters: Default baud rate of 9600, device address of 1, and flow meter constant K value of 500.
  • User-Friendly Interface: Supports command codes 0x03, 0x06, and 0x10, with CRC check for data integrity.

Specifications:

Specification Details
Product Name Flow Control Module (Mod X4)
Voltage Range DC 5-12V
Communication Protocol Modbus RUT RS485
Baud Rate 9600 (default)
Device Address 1 (default)
Flow Meter Constant 500 (default)

Device default parameters:
Baud rate: 9600 (decimal)
MODBUS device address: 1 (decimal)
Flow meter constant K value: 500 (decimal)

Register address and Register function
0x0000 baud rate
0x0001 device address, can be modified to 0x0001-0x00FE (decimal 1-247)
0x0002 Sensor pulse K value, the value read and written is 100 times the actual value(1)
0x0003 Permanent accumulated flow high register, unit, L(1)
0x0004 Permanent cumulative flow low register, unit, L(1)
0x0005 Permanent cumulative flow decimal, the reading is 100 times the actual value, unit, L(1)
0x0006 Permanent cumulative flow pulse value(1)

0x0007 Sensor pulse K value, the value read and written is 100 times the actual value(2)
0x0008 Permanent accumulated flow high register, unit, L(2)
0x0009 Permanent cumulative flow low register, unit, L(2)
0x000A Permanent cumulative flow decimal, the reading is 100 times the actual value, unit, L(2)
0x000B Permanent cumulative flow pulse value(2)

0x000C Sensor pulse K value, the value read and written is 100 times the actual value(3)
0x000D Permanent accumulated flow high register, unit, L(3)
0x000E Permanent cumulative flow low register, unit, L(3)
0x000F Permanent cumulative flow decimal, the reading is 100 times the actual value, unit, L(3)
0x0010 Permanent cumulative flow pulse value(3)

0x0011 Sensor pulse K value, the value read and written is 100 times the actual value(4)
0x0012 Permanent accumulated flow high register, unit, L(4)
0x0013 Permanent cumulative flow low register, unit, L(4)
0x0014 Permanent cumulative flow decimal, the reading is 100 times the actual value, unit, L(4)
0x0015 Permanent cumulative flow pulse value(4)

0x0016 Temporary accumulated flow high register, unit, L(1)
0x0017 Temporary accumulated flow low register, unit, L(1)
0x0018 Temporary cumulative flow decimal, the reading is 100 times the actual value, unit, L(1)
0x0019 Temporary cumulative flow pulse value(1)
0x001A Real-time flow, unit: L/min, the reading is 100 times the actual value(1)
0x001B Pulse number for current second, unit: Hz (1)

0x001C Temporary accumulated flow high register, unit, L(2)
0x001D Temporary accumulated flow low register, unit, L(2)
0x001E Temporary cumulative flow decimal, the reading is 100 times the actual value, unit, L(2)
0x001F Temporary cumulative flow pulse value(2)
0x0020 Real-time flow, unit: L/min, the reading is 100 times the actual value(2)
0x0021 Pulse number for current second, unit: Hz (2)

0x0022 Temporary accumulated flow high register, unit, L(3)
0x0023 Temporary accumulated flow low register, unit, L(3)
0x0024 Temporary cumulative flow decimal, the reading is 100 times the actual value, unit, L(3)
0x0025 Temporary cumulative flow pulse value(3)
0x0026 Real-time flow, unit: L/min, the reading is 100 times the actual value(3)
0x0027 Pulse number for current second, unit: Hz (3)
0x0028 Temporary accumulated flow high register, unit, L(4)
0x0029 Temporary accumulated flow low register, unit, L(4)
0x002A Temporary cumulative flow decimal, the reading is 100 times the actual value, unit, L(4)
0x002B Temporary cumulative flow pulse value(4)
0x002C Real-time flow, unit: L/min, the reading is 100 times the actual value(4)

0x002D Pulse number for current second, unit: Hz (4)

0x002E output point 1, control solenoid valve 1, input 0x00FF, turn on, other value, turn off
0x002F output point 2, control solenoid valve 2, input 0x00FF, turn on, other value, turn off
0x0030 output point 3, control solenoid valve 3, input 0x00FF, turn on, other value, turn off
0x0031 output point 4, control solenoid valve 4, input 0x00FF, turn on, other value, turn off

The baud rate defaults to 9600 and the reading is 2.

If you modify the baud rate, please modify the parameters as follows.

(The parameters that can be modified are 0-3. If the data input is not a value between 0-1, the baud rate is 9600, but it will be displayed as the modified value is not 0 when reading)
Register parameters Baud rate
0 2400
1 4800
2 9600
3 19200

Precautions:

  1. After modifying the address, baud rate, K value, and permanent cumulative flow, restart the device for changes to take effect.
  2. Close the pipeline before clearing accumulated flow to ensure accurate resetting.
  3. Temporary accumulated flow clears after power failure; permanent accumulated flow records every 60 seconds with a flow rate change exceeding 1L.