Ammonia Gas Detector with Pump - NH3 Range Options

Mcooh
INS03-8066
$711.32
Performance Grade :
Measure Range :
$802.83

Choose an ammonia detector around the required NH3 range and sensor configuration. The MH2000-NH3 uses an internal sampling pump to draw a gas sample to its electrochemical sensor. Standard options cover six ranges from 0-100 to 0-5000 ppm; the High Precision configuration uses a CITY sensor and offers separate 0-50, 0-100 and 0-1000 ppm versions. Select the configuration and range together when ordering. Each option is one detector with its selected measuring span.

Choose the Sensor Configuration and Range

Configuration Available measuring ranges
Standard 0-100 / 200 / 500 / 1000 / 2000 / 5000 ppm
High Precision (CITY) 0-50 / 100 / 1000 ppm

Both configurations measure ammonia. A 0-100 ppm Standard option and a 0-100 ppm High Precision option are different sensor configurations, even though they share a measuring span. Choose the span for the expected concentration and measurement task; the maximum available range is not the range of every instrument. The configuration selector shows the combinations available to order.

Pump Sampling and On-Instrument Controls

The pump provides up to 1 L/min flow with ten adjustment settings. The LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available, with ppm and mg/m³ concentration displays. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup.

Two alarm stages have adjustable setpoints. Sound, light and vibration provide different alert outputs, including an 85 dB sound alarm and blue low-alarm/red high-alarm indicators. Use the supplied instructions and the measurement procedure for setup and operation.

Specifications

Item Specification
Model MH2000-NH3
Detected gas Ammonia (NH3)
Sensor principle Electrochemical
Sensor configurations Standard; High Precision (CITY sensor)
Standard ranges 0-100, 0-200, 0-500, 0-1000, 0-2000 and 0-5000 ppm
High Precision ranges 0-50, 0-100 and 0-1000 ppm
Sampling method Internal sampling pump
Pump flow Up to 1 L/min
Pump adjustment 10 settings
Display LCD dot matrix; gas type, concentration, unit, battery level and time
Operating languages English and Chinese
Concentration units ppm / mg/m³
Alarm outputs Sound, light and vibration
Alarm stages Two
Alarm setpoints User adjustable
Sound alarm 85 dB
Alarm lights Blue for low alarm; red for high alarm
Measurement compensation Temperature and pressure compensation
Instrument controls Self-check, zero calibration and factory reset
Battery 3.6 V, 2300 mAh rechargeable lithium polymer
Charging time 4-6 hours
Operating temperature -20°C to 50°C
Operating humidity 0-95% RH, non-condensing
Protection rating IP65
Dimensions 205 x 75 x 32 mm
Instrument weight 300 g
Data recording / PC export Optional; excluded from the High Precision base options

Recording Options and Supplied Instrument

Data logging and PC export are optional and are not included in these High Precision base options. If measurement records are required, ask about the recording configuration before ordering. Optional sampling filters, drying accessories and high-temperature probes are separate choices; their appearance in a product gallery does not establish that they are included with every option.

The instrument weighs 300 g and has a rechargeable lithium-polymer battery. Gallery images illustrate the shared instrument housing, including views with a carrying case. An image showing several views of the detector does not represent a multi-detector order. For use, follow the instructions supplied with the selected NH3 instrument.

Free Shipping

Free shipping is available on all orders. Shipping methods and carriers may vary depending on the destination, order details, and available logistics options. Full Shipping Policy

Returns Policy

For returns and refunds, please review our full Refund Policy before placing an order. If you need help with an order, contact us before your order has shipped whenever possible. Full Returns Policy

When Will My Order Ship?

For Standard Shipping, we aim to pack and ship out your order within 4 business days. During special periods, such as heavy order processing or local inventory shortages that require deployment, please expect it to take an additional day or two for processing. We ship five days a week, Monday through Friday.
You will receive a shipment confirmation with tracking information via email when your order has shipped. Once you receive this email, we cannot change or cancel your order.

Can I Change The Shipping Address On My Order?

Please contact us immediately via email if you realize that you gave us the wrong shipping address — if it hasn't shipped yet, we might be able to correct it before it goes out the door.
If your order ships to the address provided and is returned to us as undeliverable, then you are responsible for paying the cost of shipping again to resend it to you. If you decide you do not want your order reshipped, we'll refund you for the products less the original shipping charges, once your order returns to our warehouse. We'll reach out to you to coordinate your options before re-shipping.
If your order ships to an incorrect address provided at the time the order is placed and is not retrievable, we are not responsible and cannot offer reimbursement.

Unable to find satisfactory answers ? more FAQs
You have successfully subscribed!
This email has been registered