Portable Pump 4 Gas Monitor with Color LCD
Portable Pump 4 Gas Monitor with Color LCD - LEL + O2 + CO + H2S Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.
See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.
Portable Pump 4 Gas Monitor with Color LCD - LEL + O2 + CO + H2S Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
Compare the Pumped Four-Gas Package
This four-gas listing combines internal pump sampling with a color LCD and the standard LEL, O2, CO and H2S channels. Compare it when the sample-drawing arrangement and pump-status display are part of the purchase decision. Other sensor combinations shown below require a separately confirmed configuration.
Listed Purchase Options
| Option | SKU |
|---|---|
| LEL + O2 + CO + H2S | GAS-R4K8-01 |
This online option is the listed LEL + O2 + CO + H2S combination. The additional sensor choices below are not extra channels included with this SKU.
Questions That Help You Choose
Is the standard gas combination suitable?
Start with the listed LEL + O2 + CO + H2S configuration. Do not treat every gas in the sensor-options table as an installed channel.
What distinguishes it from the diffusion model?
This listing includes an internal micro pump and displays pump status. Compare the diffusion model when an internal pump is not required by the plan.
What belongs in the package comparison?
Check the configured sensors, any required sampling accessories and the charging arrangement against the proposed package.
For the buying comparison, read portable multi-gas selection guide and pump vs. diffusion selection.
Compare four-gas diffusion option.
Compare a Model with Separate Pump Variants
The BH-4A product page offers standard and pump-assisted variants. This listing describes an internal micro pump and a color LCD. Compare the supplied pump arrangement, required channel combination and display information across the chosen variants instead of assuming the two packages have identical functions.
This portable pump 4 gas monitor draws air through a built-in micro sampling pump and simultaneously displays combustible gas (LEL), oxygen (O2), carbon monoxide (CO), and hydrogen sulfide (H2S) readings on one color LCD. It is suited to field and facility checks where active sampling is preferred over relying only on natural diffusion.
Four-Gas Pump Sampling
- Standard LEL + O2 + CO + H2S detection configuration
- Built-in micro sampling pump with 10 selectable suction levels
- Color LCD displays gas name, concentration, unit, time, alarm status, pump status, and battery level
- Chinese and English interface options
- Audible, visual, and vibration alarms with sound pressure above 90 dB
- Top flashlight, large back clip, and magnetic charging connection
Supported Sensor Options
The standard purchasable configuration combines LEL, O2, CO, and H2S sensors. Other four-sensor combinations can be customized from the supported options below; contact us to confirm the required gases and measuring ranges.
| Gas | Range | Minimum Reading | Sensor Response Limit |
|---|---|---|---|
| Combustible Gas (LEL) | 0-100% LEL | 1% LEL | ≤15 s |
| Oxygen (O2) | 0-30% vol | 0.1% vol | ≤20 s |
| Carbon Monoxide (CO) | 0-1000 ppm | 1 ppm | ≤25 s |
| Hydrogen Sulfide (H2S) | 0-100 ppm | 1 ppm | ≤30 s |
| Sulfur Dioxide (SO2) | 0-100 ppm | 0.1 ppm | ≤30 s |
| Nitric Oxide (NO) | 0-250 ppm | 1 ppm | ≤60 s |
| Nitrogen Dioxide (NO2) | 0-20 ppm | 0.1 ppm | ≤25 s |
| Chlorine (Cl2) | 0-20 ppm | 0.1 ppm | ≤30 s |
| Ammonia (NH3) | 0-100 ppm | 1 ppm | ≤50 s |
| Hydrogen (H2) | 0-1000 ppm | 1 ppm | ≤60 s |
| Hydrogen Cyanide (HCN) | 0-50 ppm | 0.1 ppm | ≤200 s |
| Hydrogen Chloride (HCl) | 0-30 ppm | 0.1 ppm | ≤60 s |
| Phosphine (PH3) | 0-1000 ppm | 0.1/1 ppm | ≤25 s |
| Ozone (O3) | 0-20 ppm | 0.1 ppm | ≤50 s |
Instrument Specifications
| Sampling method | Internal micro pump with 10 suction levels |
|---|---|
| Standard gas configuration | LEL + O2 + CO + H2S |
| Linear accuracy | <±5% F.S. |
| General response time | <10 s; gas-specific sensor response limits vary |
| Alarm modes | Audible, visual, and vibration |
| Alarm sound pressure | >90 dB |
| Display | Color LCD |
| Power | 3.7 V rechargeable lithium-ion battery |
| Charging | Magnetic charging |
| Standby time | At least 30 days |
| Use time | At least 24 hours |
| Operating temperature | -35 to 65 °C |
| Operating humidity | 5-95% RH, non-condensing |
| Dimensions | 210 x 73 x 50 mm |
| Approximate weight | 0.4 kg |
| Housing / ingress protection | ABS / IP66 |
| Explosion-protection marking | Ex ib IIC T4 Gb |
Selection Notes
The standard configuration covers four common atmospheric hazards in one instrument. For another four-gas combination, contact us with the required gases and measuring ranges. Alarm settings, calibration, bump testing, and operating checks should follow the configured sensor documentation and the workplace safety procedure.