Low Range Ammonia Gas Detector - 0-10/20 ppm

Mcooh  |  SKU: GAS-A6R8-01
$1,589.39 USD
Free standard shipping to supported destinations. Taxes calculated at checkout.
Measuring Range

Need help choosing? Tell us what you need to measure.

Shipping & returns

Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.

See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

Measure low ammonia concentrations with the MH2000-NH3 Low Range gas detector. This portable electrochemical instrument uses an internal sampling pump and is offered as separate 0-10 ppm and 0-20 ppm versions. It is intended for ambient-air or odor-environment NH3 concentration checks where one of these measuring spans fits the task. Choose one range when ordering; each option is a single-gas ammonia detector.

Choose Between 0-10 and 0-20 ppm

The 0-10 ppm version has a lower maximum measuring span; the 0-20 ppm version covers a broader low-concentration interval. Select the range for the expected NH3 concentration and the measurement procedure. The range label identifies the version supplied. A detector ordered in one range does not automatically switch to the other range.

This instrument reports ammonia concentration. It does not measure general odor intensity or identify all gases contributing to an odor. Keep the target gas and the expected concentration explicit when selecting the instrument and sampling arrangement.

Pump Sampling and Adjustable Alarms

The internal pump draws a sample to the electrochemical sensor, with flow up to 1 L/min and ten adjustment settings. The LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. The operating interface supports English and Chinese, and concentration can be displayed in ppm or mg/m³.

Two alarm stages have adjustable setpoints. Sound, light and vibration outputs include an 85 dB sound alarm and blue low-alarm/red high-alarm lights. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup. Use the supplied instructions and the procedure for the intended measurement.

Specifications

Item Specification
Model MH2000-NH3
Detected gas Ammonia (NH3)
Sensor principle Electrochemical
Sensor configurations Low Range (Atmospheric), single-gas configuration
Measuring range options 0-10 and 0-20 ppm, single-gas ammonia
Sampling method Internal sampling pump
Pump flow Up to 1 L/min
Pump adjustment 10 settings
Display LCD dot matrix; gas type, concentration, unit, battery level and time
Operating languages English and Chinese
Concentration units ppm / mg/m³
Alarm outputs Sound, light and vibration
Alarm stages Two
Alarm setpoints User adjustable
Sound alarm 85 dB
Alarm lights Blue for low alarm; red for high alarm
Measurement compensation Temperature and pressure compensation
Instrument controls Self-check, zero calibration and factory reset
Battery 3.6 V, 2300 mAh rechargeable lithium polymer
Charging time 4-6 hours
Operating temperature -20°C to 50°C
Operating humidity 0-95% RH, non-condensing
Protection rating IP65
Dimensions 205 x 75 x 32 mm
Instrument weight 300 g
Data recording / PC export Optional; excluded from this base configuration

Recording and Optional Sampling Equipment

Data logging and PC export are optional and are not included in this base configuration. If stored measurement records are needed, ask about the recording option before ordering. Filters, drying accessories and high-temperature probes are separate sampling choices; their suitability and inclusion depend on the intended arrangement.

The instrument weighs 300 g and uses a rechargeable lithium-polymer battery. Gallery photos illustrate the shared housing and carrying-case views. The image with two instruments does not represent a two-unit package, and a connected cable does not establish that PC data export is included.