Low Range Ammonia Gas Detector - 0-10/20 ppm
Low Range Ammonia Gas Detector - 0-10/20 ppm - 0-10 ppm Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.
See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
Measure low ammonia concentrations with the MH2000-NH3 Low Range gas detector. This portable electrochemical instrument uses an internal sampling pump and is offered as separate 0-10 ppm and 0-20 ppm versions. It is intended for ambient-air or odor-environment NH3 concentration checks where one of these measuring spans fits the task. Choose one range when ordering; each option is a single-gas ammonia detector.
Choose Between 0-10 and 0-20 ppm
The 0-10 ppm version has a lower maximum measuring span; the 0-20 ppm version covers a broader low-concentration interval. Select the range for the expected NH3 concentration and the measurement procedure. The range label identifies the version supplied. A detector ordered in one range does not automatically switch to the other range.
This instrument reports ammonia concentration. It does not measure general odor intensity or identify all gases contributing to an odor. Keep the target gas and the expected concentration explicit when selecting the instrument and sampling arrangement.
Pump Sampling and Adjustable Alarms
The internal pump draws a sample to the electrochemical sensor, with flow up to 1 L/min and ten adjustment settings. The LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. The operating interface supports English and Chinese, and concentration can be displayed in ppm or mg/m³.
Two alarm stages have adjustable setpoints. Sound, light and vibration outputs include an 85 dB sound alarm and blue low-alarm/red high-alarm lights. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup. Use the supplied instructions and the procedure for the intended measurement.
Specifications
| Item | Specification |
|---|---|
| Model | MH2000-NH3 |
| Detected gas | Ammonia (NH3) |
| Sensor principle | Electrochemical |
| Sensor configurations | Low Range (Atmospheric), single-gas configuration |
| Measuring range options | 0-10 and 0-20 ppm, single-gas ammonia |
| Sampling method | Internal sampling pump |
| Pump flow | Up to 1 L/min |
| Pump adjustment | 10 settings |
| Display | LCD dot matrix; gas type, concentration, unit, battery level and time |
| Operating languages | English and Chinese |
| Concentration units | ppm / mg/m³ |
| Alarm outputs | Sound, light and vibration |
| Alarm stages | Two |
| Alarm setpoints | User adjustable |
| Sound alarm | 85 dB |
| Alarm lights | Blue for low alarm; red for high alarm |
| Measurement compensation | Temperature and pressure compensation |
| Instrument controls | Self-check, zero calibration and factory reset |
| Battery | 3.6 V, 2300 mAh rechargeable lithium polymer |
| Charging time | 4-6 hours |
| Operating temperature | -20°C to 50°C |
| Operating humidity | 0-95% RH, non-condensing |
| Protection rating | IP65 |
| Dimensions | 205 x 75 x 32 mm |
| Instrument weight | 300 g |
| Data recording / PC export | Optional; excluded from this base configuration |
Recording and Optional Sampling Equipment
Data logging and PC export are optional and are not included in this base configuration. If stored measurement records are needed, ask about the recording option before ordering. Filters, drying accessories and high-temperature probes are separate sampling choices; their suitability and inclusion depend on the intended arrangement.
The instrument weighs 300 g and uses a rechargeable lithium-polymer battery. Gallery photos illustrate the shared housing and carrying-case views. The image with two instruments does not represent a two-unit package, and a connected cable does not establish that PC data export is included.