Digital Glass Thickness Meter LS201 for Double and Triple Glazing
Digital Glass Thickness Meter LS201 for Double and Triple Glazing Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.
See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.
Digital Glass Thickness Meter LS201 for Double and Triple Glazing Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
The Linshang LS201 digital glass thickness meter displays glass-layer and air-gap readings from one side of a glazing unit. Laser reflection and CCD detection support checks on double glazing, triple glazing and laminated assemblies. The digital readout helps document pane and cavity dimensions when access to the glass edge is limited.

Read the glazing structure
The meter covers glass thickness up to 70mm and air-space thickness up to 45mm. For a triple-glazed unit, its display can identify three glass layers and two intervening air spaces. The stated measurement accuracy is ±(0.1mm + 1%H), where H is the reference thickness.
For laminated glass, the laminate interlayer cannot be measured independently. Its thickness is included in an adjacent glass value, and the instrument may show a combined glass result when it cannot resolve the internal interface. Account for this behavior when interpreting a laminated assembly.

Automatic and manual measurement
Automatic mode can present several possible layer results for review. Select the result that matches the sample structure. Manual mode lets the operator enter layer types and estimated thicknesses when the automatic results do not fit the glazing. Keep the expected glass arrangement available when checking a complex unit.
Details and specifications
| Model | Linshang LS201 |
|---|---|
| Measurement principle | Laser reflection with CCD detection |
| Glass / air-space range | Up to 70mm / up to 45mm |
| Measurement accuracy | ±(0.1mm + 1%H), H is reference thickness |
| Modes | Automatic and manual |
| Display | 240 x 160 dot-matrix LCD |
| Minimum measurement area | 5 x 50mm |
| Power | Four alkaline batteries |
| Dimensions | 130 x 72 x 33mm |
| Net weight | 330g |
Preparing an installed-window check
Place the back of the instrument closely against a clean glass surface. Strong direct sunlight, dirt, scratches or a highly reflective low-E layer can prevent layer identification. Where appropriate, change the accessible measurement surface and review the result against the known assembly.
Keep the detector clean and avoid looking into the rear laser outlet. Check that people on the other side of the glass are clear of the beam before taking a reading. English and Chinese interface settings are available.