Ethylene Oxide Gas Detector - Electrochemical Pump Sampling
Ethylene Oxide Gas Detector - Electrochemical Pump Sampling - 0-10 ppm In stock. Shipping calculated at checkout.
In-stock orders usually take 2–4 business days to prepare; delivery typically takes 5–15 business days after dispatch. Availability is confirmed at checkout. Duties and taxes may apply. Shipping details · Return conditions
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
See our shipping policy for preparation and delivery information, and our return policy for return conditions.
For a delivery estimate to your destination, contact Mcooh.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
Choose an electrochemical ethylene oxide detector by the concentration span required for your measurement. The MH2000-EO uses internal pump sampling and is available in six Standard versions, from 0-10 ppm through 0-1000 ppm. Ethylene oxide may also be identified as EO or EtO.
Six Standard Range Options
The 0-10, 0-50 and 0-100 ppm versions cover lower maximum concentrations. For a wider measuring interval, select 0-200, 0-500 or 0-1000 ppm. Every option starts at zero and measures the same gas using the electrochemical configuration.
The range selected when ordering is the measuring span of that instrument. A six-option menu does not mean that one detector switches between all six spans. Match the chosen upper limit to the expected concentration and the requirements of the measurement procedure.
Specifications
| Item | Specification |
|---|---|
| Model | MH2000-EO |
| Detected gas | Ethylene oxide (EO / EtO) |
| Sensor principle | Electrochemical |
| Configuration | Standard |
| Measuring range options | 0-10 ppm; 0-50 ppm; 0-100 ppm; 0-200 ppm; 0-500 ppm; 0-1000 ppm |
| Sampling method | Internal sampling pump |
| Pump flow | Up to 1 L/min |
| Display | LCD dot matrix; gas type, concentration, unit, battery level and time |
| Concentration units | ppm / mg/m³ |
| Alarm outputs | Sound, light and vibration |
| Sound alarm | 85 dB |
| Low alarm light | Blue |
| High alarm light | Red |
| Alarm setpoints | User adjustable |
| Calibration functions | Self-calibration and zero calibration |
| Factory reset | Supported |
| Housing | High-strength engineering plastic |
| Battery | 3.6 V, 2300 mAh rechargeable lithium polymer |
| Charging time | 4-6 hours |
| Operating temperature | -20°C to 50°C |
| Operating humidity | 0-95% RH, non-condensing |
| Protection rating | IP65 |
| Dimensions | 205 x 75 x 32 mm |
| Instrument weight | 300 g |
Readings and Instrument Controls
The LCD presents the concentration, gas identification, selected unit, battery level and time together. Concentration units can be changed between ppm and mg/m³. Sound, light and vibration provide alarm outputs, and the alarm setpoints are adjustable.
Self-calibration and zero calibration are available for instrument setup, along with a factory reset. Follow the supplied instructions for the selected measuring version when using these controls.
Sampling and Order Details
The operating limits in the table apply to the instrument. Select the sampling arrangement to keep the measurement within those temperature and non-condensing humidity conditions. If stored readings or PC downloads are required, specify the recording and export arrangement when ordering. Filters, drying accessories and probes are separate package choices.
This link covers the Standard electrochemical configuration. The PID PPM configuration is offered as a separate product. Gallery photographs show the shared pump-detector housing; displayed readings are illustrative, and the carrying-case view does not represent a two-instrument package.