Test & measurement instruments

Ethylene Oxide Gas Detector - Electrochemical Pump Sampling

Mcooh  |  SKU: GAS-E6T8-01
$698.76 USD
Taxes and shipping calculated at checkout.
Measuring Range

In-stock orders usually take 2–4 business days to prepare; delivery typically takes 5–15 business days after dispatch. Availability is confirmed at checkout. Duties and taxes may apply. Shipping details · Return conditions

Need help choosing? Tell us what you need to measure.

Shipping & returns

See our shipping policy for preparation and delivery information, and our return policy for return conditions.

For a delivery estimate to your destination, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

Choose an electrochemical ethylene oxide detector by the concentration span required for your measurement. The MH2000-EO uses internal pump sampling and is available in six Standard versions, from 0-10 ppm through 0-1000 ppm. Ethylene oxide may also be identified as EO or EtO.

Six Standard Range Options

The 0-10, 0-50 and 0-100 ppm versions cover lower maximum concentrations. For a wider measuring interval, select 0-200, 0-500 or 0-1000 ppm. Every option starts at zero and measures the same gas using the electrochemical configuration.

The range selected when ordering is the measuring span of that instrument. A six-option menu does not mean that one detector switches between all six spans. Match the chosen upper limit to the expected concentration and the requirements of the measurement procedure.

Specifications

Item Specification
Model MH2000-EO
Detected gas Ethylene oxide (EO / EtO)
Sensor principle Electrochemical
Configuration Standard
Measuring range options 0-10 ppm; 0-50 ppm; 0-100 ppm; 0-200 ppm; 0-500 ppm; 0-1000 ppm
Sampling method Internal sampling pump
Pump flow Up to 1 L/min
Display LCD dot matrix; gas type, concentration, unit, battery level and time
Concentration units ppm / mg/m³
Alarm outputs Sound, light and vibration
Sound alarm 85 dB
Low alarm light Blue
High alarm light Red
Alarm setpoints User adjustable
Calibration functions Self-calibration and zero calibration
Factory reset Supported
Housing High-strength engineering plastic
Battery 3.6 V, 2300 mAh rechargeable lithium polymer
Charging time 4-6 hours
Operating temperature -20°C to 50°C
Operating humidity 0-95% RH, non-condensing
Protection rating IP65
Dimensions 205 x 75 x 32 mm
Instrument weight 300 g

Readings and Instrument Controls

The LCD presents the concentration, gas identification, selected unit, battery level and time together. Concentration units can be changed between ppm and mg/m³. Sound, light and vibration provide alarm outputs, and the alarm setpoints are adjustable.

Self-calibration and zero calibration are available for instrument setup, along with a factory reset. Follow the supplied instructions for the selected measuring version when using these controls.

Sampling and Order Details

The operating limits in the table apply to the instrument. Select the sampling arrangement to keep the measurement within those temperature and non-condensing humidity conditions. If stored readings or PC downloads are required, specify the recording and export arrangement when ordering. Filters, drying accessories and probes are separate package choices.

This link covers the Standard electrochemical configuration. The PID PPM configuration is offered as a separate product. Gallery photographs show the shared pump-detector housing; displayed readings are illustrative, and the carrying-case view does not represent a two-instrument package.