Hydrogen Cyanide Gas Detector - 10/50/100 ppm

Mcooh  |  SKU: GAS-H6N8-01
$934.36 USD
Taxes and shipping calculated at checkout.
Measuring Range

In-stock orders usually take 2–4 business days to prepare; delivery typically takes 5–15 business days after dispatch. Availability is confirmed at checkout. Duties and taxes may apply. Shipping details · Return conditions

Need help choosing? Tell us what you need to measure.

Shipping & returns

See our shipping policy for preparation and delivery information, and our return policy for return conditions.

For a delivery estimate to your destination, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

The MH2000-HCN Standard detector measures hydrogen cyanide concentration with an electrochemical sensor and internal pump sampling. Choose a 0-10, 0-50 or 0-100 ppm version for the concentration interval required by your measurement procedure.

Three Standard HCN Range Options

Each option starts at zero and has a different upper measuring limit. The selected range identifies the version supplied with the order. A three-option menu represents three instrument configurations; one detector is supplied with its selected span.

This link covers the Standard electrochemical configuration. A separate HCN configuration is available for smelting applications when the measurement specification calls for that sensor arrangement. Identify the gas, performance configuration and range together when selecting the instrument.

Display and Sampling Controls

The internal pump has ten adjustable suction levels, with flow up to 1 L/min. The LCD displays concentration alongside the gas type, unit, battery level and time. English and Chinese interfaces are available. Units can be switched between µmol/mol, ppm and mg/m³, with 1 µmol/mol equal to 1 ppm.

Adjustable setpoints control the two-stage sound and light alarms, and vibration is also available as an alarm output. Instrument setup includes self-check, zero calibration, factory reset, and temperature and pressure compensation functions. Use the supplied instructions for the selected HCN version.

Specifications

Item Specification
Model MH2000-HCN
Detected gas Hydrogen cyanide (HCN)
Sensor principle Electrochemical
Configuration Standard
Measuring range options 0-10 ppm; 0-50 ppm; 0-100 ppm
Gas configuration Single-gas HCN
Sampling method Internal sampling pump
Pump flow Up to 1 L/min
Pump adjustment 10 suction levels
Display LCD dot matrix; gas type, concentration, unit, battery level and time
Concentration units µmol/mol, ppm, mg/m³; 1 µmol/mol = 1 ppm
Interface languages English / Chinese
Alarm outputs Sound, light and vibration
Alarm stages Two-stage sound and light alarms
Sound alarm 85 dB
Alarm lights Blue low alarm / red high alarm
Alarm setpoints User adjustable
Setup functions Self-check and zero calibration
Factory reset Supported
Compensation functions Temperature and pressure compensation
Housing High-strength engineering plastic
Battery 3.6 V, 2300 mAh rechargeable lithium polymer
Charging time 4-6 hours
Operating temperature -20°C to 50°C
Operating humidity 0-95% RH, non-condensing
Protection rating IP65
Dimensions 205 x 75 x 32 mm
Instrument weight 300 g
Data recording Optional; more than 100,000 records
Recording interval 5-3600 seconds, adjustable with optional recording
PC transfer USB download and printing with optional data function

Recording and Supplied Package

Data recording and USB download or printing are optional functions. The recording option stores more than 100,000 readings, with intervals adjustable from 5 to 3600 seconds. Specify these functions when the procedure requires recorded measurements or PC transfer.

The standard package contains the detector, carrying case, charging/data cable and instruction manual. Gallery photographs illustrate the shared pump housing and controls. Screen readings are illustrative. The order contains one detector, and recording is supplied only when selected as an optional function.