Low Range Hydrogen Detector - 0.001 ppm Resolution
Low Range Hydrogen Detector - 0.001 ppm Resolution - 0-10 ppm In stock. Shipping calculated at checkout.
In-stock orders usually take 2–4 business days to prepare; delivery typically takes 5–15 business days after dispatch. Availability is confirmed at checkout. Duties and taxes may apply. Shipping details · Return conditions
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
See our shipping policy for preparation and delivery information, and our return policy for return conditions.
For a delivery estimate to your destination, contact Mcooh.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
The MH2000-H2 Low Range detector measures hydrogen concentration using an electrochemical sensor and an internal sampling pump. Choose a 0-10 ppm or 0-20 ppm version, both with 0.001 ppm resolution. This is a portable, single-gas H2 configuration for low-concentration measurement tasks that fit one of these spans. Select the measuring range when ordering; one instrument is supplied with the selected version.
Two Low Measuring Ranges
The 0-10 ppm option has a lower maximum measuring span, while the 0-20 ppm option covers a broader low-concentration interval. Both offer the same stated 0.001 ppm resolution. Match the required hydrogen range to the concentration expected in the sample and the measurement procedure. A detector ordered in one range does not automatically switch to the other version.
Sampling and On-Instrument Controls
The pump provides up to 1 L/min flow and ten adjustment settings. The LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available, and hydrogen concentration can be displayed in ppm or mg/m³.
Two alarm stages have adjustable setpoints, with sound, light and vibration outputs. The sound alarm is 85 dB; blue and red lights indicate low and high alarms. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup. Follow the supplied instructions for the low-range H2 configuration and the procedure used for the measurement.
Specifications
| Item | Specification |
|---|---|
| Model | MH2000-H2 |
| Detected gas | Hydrogen (H2) |
| Sensor principle | Electrochemical |
| Configuration | High Precision, Low Range, single-gas |
| Measuring range options | 0-10 or 0-20 ppm |
| Resolution | 0.001 ppm for both Low Range options |
| Sampling method | Internal sampling pump |
| Pump flow | Up to 1 L/min |
| Pump adjustment | 10 settings |
| Display | LCD dot matrix; gas type, concentration, unit, battery level and time |
| Operating languages | English and Chinese |
| Concentration units | ppm / mg/m³ |
| Alarm outputs | Sound, light and vibration |
| Alarm stages | Two |
| Alarm setpoints | User adjustable |
| Sound alarm | 85 dB |
| Alarm lights | Blue for low alarm; red for high alarm |
| Measurement compensation | Temperature and pressure compensation |
| Instrument controls | Self-check, zero calibration and factory reset |
| Battery | 3.6 V, 2300 mAh rechargeable lithium polymer |
| Charging time | 4-6 hours |
| Operating temperature | -20°C to 50°C |
| Operating humidity | 0-95% RH, non-condensing |
| Protection rating | IP65 |
| Dimensions | 205 x 75 x 32 mm |
| Instrument weight | 300 g |
| Data recording / PC export | Optional; excluded from this base configuration |
Recording and Sampling Options
Data logging and PC export are optional and are not included in this base configuration. Where stored records are required, ask about the recording option before ordering. Sampling filters, drying accessories and high-temperature probes are separate package choices; their suitability and inclusion depend on the intended arrangement.
The instrument weighs 300 g and uses a rechargeable lithium-polymer battery. Gallery photographs illustrate the shared pump-detector housing, including views with a carrying case. The case image does not represent a two-instrument package, and a connected cable does not establish that PC export is included.