Test & measurement instruments

Split Transmission Meter LS110A - 940 nm IR for Installed Glass

Linshang  |  SKU: INS02-2136
$492.40 USD
Taxes and shipping calculated at checkout.

In-stock orders usually take 2–4 business days to prepare; delivery typically takes 5–15 business days after dispatch. Availability is confirmed at checkout. Duties and taxes may apply. Shipping details · Return conditions

Need help choosing? Tell us what you need to measure.

Shipping & returns

See our shipping policy for preparation and delivery information, and our return policy for return conditions.

For a delivery estimate to your destination, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

The Linshang LS110A split transmission meter measures visible-light transmission, 365 nm UV rejection and 940 nm infrared rejection on installed glass. Its separate main and auxiliary units support checks on automotive windshields, architectural glazing and larger film-covered panels.

Three optical readings across an installed pane

The visible channel covers 380–760 nm with CIE photopic weighting. The UV and infrared values describe rejection at their specified source wavelengths, and all three readings appear on the display together. Record the 940 nm channel when comparing film samples or sharing results.

Place the two halves on opposite sides of a sample area greater than 40 x 40 mm. The magnetic split design and parallel optical path allow testing on fitted panes. For glass thicker than 20 mm, support the halves by hand as magnetic holding strength decreases with separation.

LS110A illustration showing the separate main and auxiliary units
LS110A illustration showing the separate main and auxiliary units

Pair, align and complete self-test

Start with both parts together and no sample between them. Power on each half, align the laser spots with the target marks and wait for self-test. The starting display shows 100% VLT and 0% IRR/UVR.

After inserting the sample, use HOLD to retain the result for viewing. Release hold before the next check. Direct the alignment beams at their target marks and measure away from direct sunlight for consistent conditions.

LS110A wavelength and instrument data

UV peak wavelength 365 nm
IR peak wavelength 940 nm
Visible-light response 380–760 nm, CIE photopic luminosity function
Accuracy ±2% for colorless, uniformly transparent material
Resolution 0.1% below 10%; 1% in other ranges
Sample size Greater than 40 x 40 mm
Power Built-in rechargeable lithium battery
Dimensions 130 x 70 x 84 mm
Weight 630 g
Operating conditions 0–50°C; 0–85% RH, non-condensing
LS110A illustration of simultaneous USB charging
LS110A illustration of simultaneous USB charging

Recharge for repeated site measurements

Built-in lithium batteries power the two units. Their USB charging connections allow both halves to be charged for the next series of checks. The meter automatically shuts down after fifteen minutes without operation.

The accuracy specification applies to colorless, uniformly transparent material. Keep the same instrument, alignment and sample position when evaluating a series, particularly when the glass has a colored or optical coating.