UV Power Meter LS123 for Solar Film and Glass Checks
UV Power Meter LS123 for Solar Film and Glass Checks Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.
See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
The Linshang LS123 UV power meter checks ultraviolet irradiance and the UV rejection of solar film or glass. Its 260–380 nm response peaks at 365 nm, with readings in μW/cm² for sunlight and lower-intensity UV film demonstrations.

Establish a UV reference for film and glass checks
Place the detector facing the UV source and record the incident irradiance with the optical path clear. Press 0% to set the rejection reference, then insert the sample between the source and the detector. Keep the source and meter fixed while taking the transmitted reading.
The display calculates UV rejection from the before-and-after irradiance ratio. Maintain the same source output, distance and alignment when comparing samples. A new source position requires a fresh reference before checking another film or pane.
LS123 UV measurement specifications
| Spectral response | 260–380 nm; peak 365 nm |
|---|---|
| Irradiance range | 0–40000 μW/cm² |
| Accuracy, H = reference value | H < 50 μW/cm²: ±5 μW/cm²; H ≥ 50 μW/cm²: ±10%H |
| UV rejection display | -999% to 100% |
| Detector diameter | 10 mm |
| Power supply | 4 AAA alkaline batteries |
| Dimensions | 125 x 69 x 24.5 mm |
| Weight | Approx. 140 g including batteries |

Hold the displayed result
Press HOLD to retain a measurement for easier viewing, then release it to continue testing. The meter automatically powers off after thirty minutes without operation. Its handheld body suits sample demonstrations and repeated checks with a stable external source.
Match the measurement to the response band
Use the LS123 within its stated irradiance range and 260–380 nm response. The reported rejection depends on both the material and the spectrum of the illumination. Keep those conditions with the result when comparing film or glass samples.
For consistent records, note the source, measuring position and material identity. Keep the 10 mm aperture clear and use the same detector orientation during each before-and-after comparison.