Test & measurement instruments

UV IR Visible Transmission Meter LS183 for Thick Glass

Linshang  |  SKU: TNT-2B6W-01
$464.07 USD
Free standard shipping to supported destinations. Taxes calculated at checkout.

Need help choosing? Tell us what you need to measure.

Shipping & returns

Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.

See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

The Linshang LS183 UV, IR and visible transmission meter checks transparent samples in a 47 mm-wide test opening. Its parallel optical path and large color display suit film, coated glass, laminated glass, PMMA and PC sample comparisons within the instrument’s sample-size limits.

LS183 illustration identifying UV, IR and visible transmission readings
LS183 illustration identifying UV, IR and visible transmission readings

View three transmission values together

The LS183 uses a 365 nm UV source, a 940 nm infrared source and a 380–760 nm CIE photopic visible-light response. The display shows the percentage of light transmitted through the sample in each measuring channel.

A side selector switches between three display layouts, including numerical and graphical presentations. This lets the operator choose a convenient view for repeated checks while retaining the same optical channels. Keep the channel wavelengths with the results when comparing samples.

LS183 illustration of its three display layouts
LS183 illustration of its three display layouts

Fit the sample within the 47 mm opening

Use samples less than 47 mm thick and position them consistently in the test opening. The parallel light path supports checks on thicker transparent materials, including suitable layered glazing samples. The rear support rod tilts the display for reading on a desktop.

Connect the 5 V supply and power on with the opening empty. After self-test, all three transmission readings should show 100%. Insert the sample only after this baseline is established.

LS183 instrument specifications

Measured values UV, IR and visible-light transmittance
UV peak wavelength 365 nm
IR peak wavelength 940 nm
Visible-light response 380–760 nm, CIE photopic luminosity function
Maximum sample thickness Less than 47 mm
Test opening 47 x 91 mm
Resolution 0.1%
Accuracy ±2% for colorless, uniformly transparent material
Power input 5 V DC, 1 A supply through USB Type-C
Dimensions 216 x 134 x 29 mm
Weight Approx. 590 g
Operating conditions 0–50°C; 0–85% RH, non-condensing

Maintain a consistent measurement baseline

Keep the optical openings clean and perform startup away from strong ambient light. Repeat self-calibration after prolonged use if the empty opening has drifted from its 100% baseline. Position each sample in the same way when comparing glass or film batches.

The accuracy rating applies to colorless, uniformly transparent material. For colored or optically coated samples, interpret the three channel readings under the actual measuring conditions and record the sample identity with the result.