NDT Light Meter LS331 for UV Irradiance, Illuminance and CCT
NDT Light Meter LS331 for UV Irradiance, Illuminance and CCT Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.
See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.
NDT Light Meter LS331 for UV Irradiance, Illuminance and CCT Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
The Linshang LS331 NDT light meter measures UV irradiance, visible illuminance and correlated color temperature together. It supports viewing-condition checks for fluorescent penetrant and magnetic-particle inspection work. The separate optical head can be placed at the measurement position while the handheld unit displays the readings.

Read UV and visible-light conditions together
A UV detector with a 365nm peak reference covers a 315–405nm response band. Visible illuminance is measured with a spectral sensor using the photopic response, and the screen also displays correlated color temperature. These outputs help document the lighting conditions at the inspection area.
Maximum UV and illuminance values are retained for review alongside the real-time readings. HOLD freezes the current display, and stored measurements can be retrieved on the instrument. USB connects to dedicated PC software for record reading and Excel export.

Measurement details
| Model | Linshang LS331 |
|---|---|
| UV response | 315–405nm, 365nm peak |
| UV irradiance range / resolution | 0–200000μW/cm² / 0.1μW/cm² |
| UV accuracy | Below 50μW/cm², ±5μW/cm². At or above 50μW/cm², ±10%H. H is reference irradiance. |
| Illuminance range / resolution | 0–1000000lux / 0.1lux |
| Illuminance accuracy | ≤±(4%H + 2lux), calibrated under CIE standard A. H is reference illuminance. |
| Illuminance units | Lux and foot-candles |
| CCT range | 1000–100000K |
| Response time | Less than 0.7s |
| Test aperture | 21mm diameter |
| Display / power | 240 x 160 LCD / two AA alkaline batteries |
| Instrument weight | Approx. 232g including batteries |
Set up a consistent lighting check
Position the sensor at the inspection location and keep its orientation consistent between readings. Record the source arrangement and selected units with the measurement so repeat checks use the same conditions. Appropriate UV exposure controls remain part of the inspection setup.
Choose an automatic shutdown setting that suits the measurement session, and keep the optical surface clean. Store the probe in a dry place between uses to protect its humidity-sensitive optical components. The meter's separate UV and visible readings allow each lighting quantity to be assessed against the inspection procedure being used.