PID Ethylene Oxide Gas Detector - High Precision PPM
PID Ethylene Oxide Gas Detector - High Precision PPM - 0-100 ppm Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.
See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.
PID Ethylene Oxide Gas Detector - High Precision PPM - 0-100 ppm Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
The PID ethylene oxide gas detector is the MH2000-EO High Precision PPM configuration, offered with five measuring spans. Select 0-100, 0-200, 0-1000, 0-2000 or 0-3000 ppm for the concentration interval required by your procedure. This product uses a photoionization sensor rather than the Standard electrochemical configuration.
PID Configuration and Range Selection
All five options use the PPM sensor configuration. The 0-100 and 0-200 ppm versions have lower upper limits; 0-1000, 0-2000 and 0-3000 ppm cover broader intervals. Each starts at zero. The order selection identifies one measuring version, not five ranges that can be exchanged during operation.
Sensor configuration and upper measuring limit are separate purchase decisions. A 0-100 or 0-200 ppm PID version and an electrochemical version with the same span are different configurations. Use the PID label when specifying this product, together with the selected range and ethylene oxide gas identity.
Pump Sampling and Controls
Internal pump sampling brings the sample to the instrument. The LCD shows the gas concentration together with the gas type, unit, battery level and time. Adjustable alarm points and sound, light and vibration outputs support the instrument's concentration alarm functions.
Self-calibration, zero calibration and factory reset are available. Use the supplied instructions for the selected PID version and the intended measurement procedure when setting up the instrument.
Specifications
| Item | Specification |
|---|---|
| Model | MH2000-EO |
| Detected gas | Ethylene oxide (EO / EtO) |
| Sensor principle | Photoionization (PID) |
| Configuration | High Precision, PPM sensor |
| Measuring range options | 0-100 ppm; 0-200 ppm; 0-1000 ppm; 0-2000 ppm; 0-3000 ppm |
| Sampling method | Internal sampling pump |
| Pump flow | Up to 1 L/min |
| Display | LCD dot matrix; gas type, concentration, unit, battery level and time |
| Concentration units | ppm / mg/m³ |
| Alarm outputs | Sound, light and vibration |
| Sound alarm | 85 dB |
| Low alarm light | Blue |
| High alarm light | Red |
| Alarm setpoints | User adjustable |
| Calibration functions | Self-calibration and zero calibration |
| Factory reset | Supported |
| Housing | High-strength engineering plastic |
| Battery | 3.6 V, 2300 mAh rechargeable lithium polymer |
| Charging time | 4-6 hours |
| Operating temperature | -20°C to 50°C |
| Operating humidity | 0-95% RH, non-condensing |
| Protection rating | IP65 |
| Dimensions | 205 x 75 x 32 mm |
| Instrument weight | 300 g |
Specify the Measurement Arrangement
Choose the sampling arrangement for the operating conditions listed above. Recording, PC export, filters, drying accessories and probes should be specified as order requirements when needed. Gallery views illustrate the shared housing and controls; screen readings do not identify the supplied PID sensor or range, and a case photograph does not establish a two-instrument bundle.