Measuring Range

In-stock orders usually take 2–4 business days to prepare; delivery typically takes 5–15 business days after dispatch. Availability is confirmed at checkout. Duties and taxes may apply. Shipping details · Return conditions

Need help choosing? Tell us what you need to measure.

Shipping & returns

See our shipping policy for preparation and delivery information, and our return policy for return conditions.

For a delivery estimate to your destination, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

The MH2000-VOC is a portable photoionization detector for volatile organic compound concentration readings. Its High Precision PPM sensor configuration is available in five measuring spans, with an internal pump drawing the sample to the instrument. Use it for VOC concentration checks in a painting workshop, selecting the measuring span for the sampling task.

Select the PPM Measuring Span

Choose 0-100, 0-200, 0-1000, 0-2000 or 0-5000 ppm. Each option begins at zero, and the upper limit identifies the measuring version supplied with the order. Match the chosen interval to the concentration expected by the measurement procedure.

All five order options use the PID PPM configuration. The selection menu identifies one instrument version at a time. Include the VOC configuration and selected span together when specifying the detector for purchase.

Sampling, Display and Alarm Controls

The internal pump has ten suction levels, with flow up to 1 L/min. The LCD shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are supported, and concentration display units include µmol/mol, ppm and mg/m³.

Two-stage sound and light alarms use adjustable setpoints. Self-check and zero calibration support setup, along with factory reset and temperature and pressure compensation functions. Follow the supplied instructions for the chosen VOC configuration when setting up these controls.

Specifications

Item Specification
Model MH2000-VOC
Measurement Volatile organic compounds (VOC)
Sensor principle Photoionization (PID)
Configuration High Precision, PPM sensor
Measuring range options 0-100 ppm; 0-200 ppm; 0-1000 ppm; 0-2000 ppm; 0-5000 ppm
Application example VOC concentration checks in painting workshops
Sampling method Internal sampling pump
Pump flow Up to 1 L/min
Pump adjustment 10 suction levels
Display LCD dot matrix; gas type, concentration, unit, battery level and time
Concentration units µmol/mol, ppm, mg/m³; 1 µmol/mol = 1 ppm
Interface languages English / Chinese
Alarm outputs Sound and light
Alarm stages Two-stage sound and light alarms
Sound alarm 85 dB
Alarm lights Blue low alarm / red high alarm
Alarm setpoints User adjustable
Setup functions Self-check and zero calibration
Factory reset Supported
Compensation functions Temperature and pressure compensation
Housing High-strength engineering plastic
Battery 3.6 V, 2300 mAh rechargeable lithium polymer
Charging time 4-6 hours
Operating temperature -20°C to 50°C
Operating humidity 0-95% RH, non-condensing
Protection rating IP65
Dimensions 205 x 75 x 32 mm
Instrument weight 300 g
Data recording Optional; more than 100,000 records
Recording interval 5-3600 seconds, adjustable with optional recording
PC transfer USB download and printing with optional data function

Recording Options and Package

Data recording and USB download or printing are optional. With recording fitted, storage exceeds 100,000 readings and the interval can be set from 5 to 3600 seconds. Specify these functions when the procedure requires stored measurements or PC transfer.

The standard package contains one detector, a carrying case, charging/data cable and instruction manual. Gallery photographs illustrate the shared pump-detector housing and controls; screen readings are illustrative. Optional recording is supplied when selected as an order requirement.