Test & measurement instruments

Portable 4 Gas Monitor - CO, H2S, O2 and LEL

Mcooh  |  SKU: GAS-F4P8-01
$418.41 USD
Free standard shipping to supported destinations. Taxes calculated at checkout.
Configuration
For measurements at the detector inlet. The four-channel configuration uses natural diffusion.
Sampling
Natural diffusion
Gas channels
LEL, O₂, CO, H₂S
Purchase option
One four-gas configuration
Three four-gas monitors, three sampling setups

Need help choosing? Tell us what you need to measure.

Shipping & returns

Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.

See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

This portable 4 gas monitor combines carbon monoxide, hydrogen sulfide, oxygen and combustible gas measurement in one instrument. The MH-1200H-S4 uses diffusion sampling, with electrochemical sensors for CO, H2S and O2 and a catalytic combustion sensor for the LEL channel. It provides the four readings through a monochrome LCD and uses sound, light and vibration for alarm indication.

Four Gas Channels in One Configuration

The instrument is supplied as one four-channel configuration. Each gas has its own measurement span and concentration unit:

Gas channel Measurement range Sensor principle
Carbon monoxide (CO) 0-1000 ppm Electrochemical
Hydrogen sulfide (H2S) 0-100 ppm Electrochemical
Oxygen (O2) 0-30% Vol Electrochemical
Combustible gas (LEL) 0-100% LEL Catalytic combustion

Use these channel ranges when comparing the monitor with the requirements of your monitoring procedure. CO and H2S are measured in ppm, oxygen in percent by volume and combustible gas in percent LEL. Diffusion sampling measures air at the instrument inlet. Keep the inlet exposed to the air being checked and follow the instrument instructions for calibration and pre-use checks.

Alarm Settings and Event Review

The audible alarm is rated at 85 dB, with light and vibration providing additional indications. Alarm set points can be configured for the monitoring procedure. The detector stores 100 alarm records that can be reviewed on the instrument. The 128 x 64 monochrome LCD supports English and Chinese interfaces; backlight timing can be adjusted, and the backlight turns on automatically during an alarm.

Instrument Specifications

Model MH-1200H-S4
Gas configuration CO, H2S, O2 and combustible gas
Sampling Diffusion
Display 128 x 64 monochrome LCD
Interface languages English and Chinese
Alarm modes Sound, light and vibration
Audible alarm 85 dB
Alarm settings Configurable set points
Alarm history 100 records viewable on the instrument
Backlight Adjustable timing; automatic illumination during an alarm
Battery 2300 mAh rechargeable lithium-polymer
Operating temperature -20 to 50 Degree C
Ingress protection IP65
Dimensions 131 x 83 x 35 mm
Approximate instrument weight 240 g including protective cover

Controls and Carrying Details

Zero calibration, self-calibration, battery status checks and a factory reset function are available through the instrument controls. A rechargeable 2300 mAh lithium-polymer battery powers the monitor. The housing measures 131 x 83 x 35 mm, and the instrument weighs approximately 240 g including its protective cover. A rear clip provides a carrying point during inspection rounds.

Follow the instrument instructions and your monitoring procedure for setup, calibration, checks and alarm handling. Product photos illustrate the housing shared across this series; gas names on the demonstration screen may differ from the selected configuration.