Description

The AS8800L is a flexible-probe combustible-gas leak detector. Its 35.5 cm probe, adjustable sensitivity and sound/light indications are features to compare for reaching and investigating suspected leak points. The stated methane sensitivity is not the same specification as a gas-specific measuring range.

Choose the Configuration for Your Measurement

  • Probe: 35.5 cm flexible probe for positioning at a test point.
  • Indications: Sound and light leak indications with adjustable sensitivity.
  • Power: Three AA 1.5 V alkaline batteries are specified and are not included.

Order Options

Current options for this product
Select an option SKU
Single listed configuration INS03-8504

Open an option to review its current price and purchase controls. Each option is a separate order configuration; use the selected product and SKU when confirming the supplied package.

Product Details and Specifications

Portable combustible-gas leak checks

The AS8800L combustible gas detector uses a flexible probe with audible and visual indications for checking suspected leak points. Adjustable sensitivity helps follow changes in the detected response during a leak check.

Key Features

  • Methane sensitivity: Variable sensitivity with a stated minimum of 50 ppm for methane.
  • Startup: The stated warm-up time is less than 20 seconds.
  • Dual Alarm System: Features both a loud sound alarm and a bright light alarm for audible and visible indications.
  • Flexible Probe: A 35.5cm (13.98in) flexible probe allows you to access and test in hard-to-reach areas.
  • Adjustable Sensitivity: Easily adjust the sensitivity to follow changes in the detected response.
  • Portable & Lightweight: Compact and ergonomic design makes it easy to carry and operate with one hand.
  • Low Battery Indicator: The low-battery indication prompts battery replacement.

Specifications

Detection Gas Combustible Gas
Sensitivity Variable, Minimum 50 PPM (methane)
Alarm Mode Sound and Light Alarm
Warm-Up Time < 20 Seconds
Battery Type 3 * AA 1.5V Alkaline Batteries (Not Included)
Continuous Operation Time Approx. 9 hours
Probe Length 35.5cm / 13.98in
Operating Temperature 0~50℃, Relative Humidity 0~80%
Dimensions 160 * 65 * 33mm (6.30 * 2.56 * 1.30in)
Weight 175g / 6.17oz

Compare the Relevant Alternative

The MT8800/AT8800L product also uses a flexible-probe format, and its specifications list three AAA batteries. AS8800L specifies AA batteries and a 35.5 cm probe. Confirm the model and power format; the similar product names do not establish the same package.

View the comparison model and its options.

Questions Before Ordering

Does minimum 50 ppm sensitivity mean a 0-50 ppm meter?

The stated 50 ppm figure describes methane sensitivity. For quantitative gas readings, compare a detector with a specified concentration range and display.

What if I need a concentration display in %LEL?

Compare a product that explicitly lists a %LEL display, such as CGD02. Select the reporting format required by the task rather than interpreting a leak indication as a concentration reading.

Selection and Use Guides

Selection note: Follow the supplied instrument instructions and the applicable site procedure. This product comparison does not replace a site-specific risk assessment.