MH-1200H-S-H2S Detector — Diffusion, 50/100/200 ppm

Mcooh  |  SKU: GAS-H7Q2-01
$268.12 USD
Taxes and shipping calculated at checkout.
Range

In-stock orders usually take 2–4 business days to prepare; delivery typically takes 5–15 business days after dispatch. Availability is confirmed at checkout. Duties and taxes may apply. Shipping details · Return conditions

Need help choosing? Tell us what you need to measure.

Shipping & returns

See our shipping policy for preparation and delivery information, and our return policy for return conditions.

For a delivery estimate to your destination, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

The MH-1200H-S-H2S is the diffusion hydrogen-sulfide model with separate 0-50, 0-100 and 0-200 ppm configurations. It is a single-gas choice for a named H2S measurement requirement. If other channels are required, compare a model that lists those gases explicitly.

Choose the Configuration for Your Measurement

  • Gas and options: Hydrogen sulfide, with three current range/SKU pairs.
  • Sampling: Diffusion sampling is stated in the product description.
  • Selection boundary: A single H2S instrument does not acquire O2, CO or combustible-gas channels from the application name.

Order Options

Current options for this product
Select an option SKU
0-50 ppm GAS-H7Q2-01
0-100 ppm GAS-H7Q2-02
0-200 ppm GAS-H7Q2-03

Open an option to review its current price and purchase controls. Each option is a separate order configuration; use the selected product and SKU when confirming the supplied package.

Product Details and Specifications

The MH-1200H-S-H2S is a portable hydrogen sulfide detector for H2S checks during facility and field inspections. An electrochemical sensor measures gas in the air around the instrument through diffusion sampling. The detector has a rear clip and protective cover for carrying during a measurement round. Select the required H2S range when ordering; each range is a separate product variant.

H2S Range Options

Choose from 0-50 ppm, 0-100 ppm, or 0-200 ppm according to the concentration span required for your work. The three ranges are separate order configurations. The standard configuration samples by diffusion. An external sampling pump is an optional setup for applications that need a different sampling arrangement; confirm the pump setup before ordering.

Readings, Alarms, and Records

The monochrome dot-matrix LCD shows the gas reading and concentration unit. The display supports ppm and mg/m³ units, and its backlight can be set to switch on automatically during an alarm. Audible, visual, and vibration alarms give three ways to notice an alert. Alarm points can be configured, and up to 100 alarm records can be reviewed on the detector. Zero and self-calibration functions are available on the instrument.

Technical Specifications

Model MH-1200H-S-H2S
Measured gas Hydrogen sulfide (H2S)
Sensor principle Electrochemical
Sampling method Diffusion; external pump setup optional
Range configurations 0-50 ppm; 0-100 ppm; 0-200 ppm
Display 128 x 64 monochrome dot-matrix LCD
Concentration units ppm and mg/m³
Alarm modes Sound, light, and vibration
Audible alarm 85 dB
Alarm history 100 records, viewable on the instrument
Backlight Adjustable timing; automatic activation during an alarm
Power 2300 mAh rechargeable lithium-polymer battery
Operating temperature -20 to 50 Degree C
Ingress protection IP65
Dimensions 131 x 83 x 35 mm
Approximate unit weight 240 g with protective cover

Before Use

With diffusion sampling, the surrounding air must reach the detector's sensor openings. Follow the supplied instructions and your site's procedures for calibration, alarm settings, and gas-monitoring checks. Product photos show the shared housing; the demonstration screen labels may differ from the ordered H2S configuration.

Compare the Relevant Alternative

BH-4S O2/EX/H2S/CO provides a different, four-channel configuration. This MH-1200H-S product offers a choice of H2S spans instead. Compare gas coverage first, then sampling, range and package requirements.

View the comparison model and its options.

Questions Before Ordering

Should I select H2S-only or multi-gas?

Write down all required gas channels for the task. Select this product for its H2S configuration; compare an explicitly multi-gas model when more channels are required.

Are the three ranges measured simultaneously?

They are separate variants with separate SKUs. The current selector does not establish a three-range instrument.

Selection and Use Guides

Selection note: Follow the supplied instrument instructions and the applicable site procedure. This product comparison does not replace a site-specific risk assessment.