Portable Methane Detector - CH4 0-100% LEL
Portable Methane Detector - CH4 0-100% LEL - Standard In stock. Shipping calculated at checkout.
In-stock orders usually take 2–4 business days to prepare; delivery typically takes 5–15 business days after dispatch. Availability is confirmed at checkout. Duties and taxes may apply. Shipping details · Return conditions
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
See our shipping policy for preparation and delivery information, and our return policy for return conditions.
For a delivery estimate to your destination, contact Mcooh.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
Measure methane at the instrument inlet with this portable methane gas detector. The MH-1200H-S-CH4 uses a catalytic combustion sensor and diffusion sampling to display CH4 concentration over a 0-100% LEL range. Choose either the Standard or High Performance sensor configuration when ordering.
CH4 Measurement and Sensor Selection
Both performance options use the same 0-100% LEL methane measurement span. Standard is the conventional catalytic configuration; High Performance uses a poisoning-resistant catalytic sensor. The Standard configuration is not recommended for diesel or acetylene environments. Select the sensor option that matches the gases and conditions in your monitoring procedure, and follow the instrument instructions for calibration and pre-use checks.
This configuration uses diffusion sampling at the sensor inlet. Keep the inlet exposed to the air being checked. The rear clip provides a carrying point during inspection rounds, and the protective cover surrounds the compact housing.
Readings, Alarm Settings and Stored Events
The 128 x 64 monochrome LCD shows gas information and concentration. Adjustable backlight timing lets you set the display illumination through the controls; the backlight also activates automatically during an alarm. Sound, light and vibration provide alarm indications, with an 85 dB audible alarm and configurable set points. The detector stores 100 alarm records for review on its screen.
Technical Specifications
| Model | MH-1200H-S-CH4 |
|---|---|
| Measured gas | Methane (CH4) |
| Sensor principle | Catalytic combustion |
| Measurement range | 0-100% LEL |
| Performance options | Standard; High Performance |
| Sampling | Diffusion |
| Display | 128 x 64 monochrome LCD |
| Alarm modes | Sound, light and vibration |
| Audible alarm | 85 dB |
| Alarm settings | Configurable set points |
| Alarm history | 100 records viewable on the instrument |
| Backlight | Adjustable timing; automatic illumination during an alarm |
| Battery | 2300 mAh rechargeable lithium-polymer |
| Operating temperature | -20 to 50 Degree C |
| Ingress protection | IP65 |
| Dimensions | 131 x 83 x 35 mm |
| Approximate instrument weight | 240 g including protective cover |
Controls and Carrying Details
Zero calibration, self-calibration, battery status checks and a factory reset function are available through the instrument controls. Set up and check the instrument according to its instructions and the requirements of your methane monitoring procedure.
A rechargeable 2300 mAh lithium-polymer battery powers the detector. The housing measures 131 x 83 x 35 mm, and the instrument weighs approximately 240 g including its protective cover. Product photos show the housing shared across this series; gas labels on the demonstration screen may differ from the selected CH4 configuration.