Hydrogen Gas Detector with Pump - 1000 to 40000 ppm
Hydrogen Gas Detector with Pump - 1000 to 40000 ppm - 0-1000 ppm In stock. Shipping calculated at checkout.
In-stock orders usually take 2–4 business days to prepare; delivery typically takes 5–15 business days after dispatch. Availability is confirmed at checkout. Duties and taxes may apply. Shipping details · Return conditions
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
See our shipping policy for preparation and delivery information, and our return policy for return conditions.
For a delivery estimate to your destination, contact Mcooh.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
Choose the MH2000-H2 pump hydrogen detector in the measuring span required for the sample. Six Standard electrochemical versions are available: 0-1000, 0-2000, 0-5000, 0-10000, 0-20000 and 0-40000 ppm. The internal pump draws a gas sample to the sensor, and the instrument displays hydrogen concentration on its LCD screen. Each range is a separate supplied version of this portable, single-gas H2 detector.
Select One of Six Hydrogen Ranges
The range selector identifies the maximum concentration span of the version supplied. Select a 1000, 2000, 5000, 10000, 20000 or 40000 ppm option for the expected concentration and the measurement procedure. One detector does not automatically cover every range shown on this page. Keep the target gas and the required measuring interval explicit when choosing the instrument.
Controls for Pump Sampling
Pump flow reaches up to 1 L/min, with ten adjustment settings. The LCD dot-matrix display presents the gas type, concentration, unit, battery level and time. The operating interface supports English and Chinese, and concentration can be displayed in ppm or mg/m³. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup.
Two alarm stages have adjustable setpoints. Sound, light and vibration provide multiple alert outputs, including an 85 dB sound alarm and blue low-alarm/red high-alarm lights. Operate the selected H2 version according to its supplied instructions and the sampling procedure for the work.
Specifications
| Item | Specification |
|---|---|
| Model | MH2000-H2 |
| Detected gas | Hydrogen (H2) |
| Sensor principle | Electrochemical |
| Configuration | Standard |
| Measuring range options | 0-1000, 0-2000, 0-5000, 0-10000, 0-20000 or 0-40000 ppm |
| Sampling method | Internal sampling pump |
| Pump flow | Up to 1 L/min |
| Pump adjustment | 10 settings |
| Display | LCD dot matrix; gas type, concentration, unit, battery level and time |
| Operating languages | English and Chinese |
| Concentration units | ppm / mg/m³ |
| Alarm outputs | Sound, light and vibration |
| Alarm stages | Two |
| Alarm setpoints | User adjustable |
| Sound alarm | 85 dB |
| Alarm lights | Blue for low alarm; red for high alarm |
| Measurement compensation | Temperature and pressure compensation |
| Instrument controls | Self-check, zero calibration and factory reset |
| Battery | 3.6 V, 2300 mAh rechargeable lithium polymer |
| Charging time | 4-6 hours |
| Operating temperature | -20°C to 50°C |
| Operating humidity | 0-95% RH, non-condensing |
| Protection rating | IP65 |
| Dimensions | 205 x 75 x 32 mm |
| Instrument weight | 300 g |
| Data recording / PC export | Optional; excluded from this base configuration |
Supplied Configuration and Optional Recording
The instrument has a rechargeable lithium-polymer battery and weighs 300 g. Data logging and PC export are optional and are not included in this base configuration. If recorded readings are needed, ask about the recording package before ordering. Sampling filters, drying accessories and high-temperature probes are separate choices; do not infer that they are included in every configuration.
Gallery photos illustrate the shared instrument housing. A connected cable does not indicate included PC export, and the carrying-case photo does not represent a two-detector order. Select the required hydrogen range as a separate order option.