Sulfur Dioxide Gas Detector with Pump - 20 to 2000 ppm
Sulfur Dioxide Gas Detector with Pump - 20 to 2000 ppm - Standard / 0-20 ppm Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.
See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.
Sulfur Dioxide Gas Detector with Pump - 20 to 2000 ppm - Standard / 0-20 ppm Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
The MH2000-SO2 pump detector measures sulfur dioxide with an electrochemical sensor. Choose one of three Standard ranges or four High Performance ranges to match the SO2 concentration span required by the measurement task. Both configurations on this page are for applications outside flue-gas environments.
Standard and High Performance Options
| Sensor configuration | Measuring ranges | Application limit |
|---|---|---|
| Standard | 0-20 / 50 / 100 ppm | Not suitable for flue gas |
| High Performance | 0-200 / 500 / 1000 / 2000 ppm | Not suitable for flue gas |
Select the performance grade and measuring range together when ordering. One instrument is supplied with the chosen sensor and span; it does not automatically switch between all seven versions. The High Performance grade identifies a configuration and does not establish a numerical accuracy value. Choose the separate flue-gas-specific SO2 configuration when that application is required.
Sampling, Readings and Controls
An internal pump delivers up to 1 L/min flow with ten adjustment settings. The LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available. Concentration units include μmol/mol, ppm and mg/m³, with 1 μmol/mol equivalent to 1 ppm.
Two adjustable alarm stages use sound, light and vibration outputs. The sound alarm is 85 dB, and blue/red lights indicate the alarm levels. Temperature and pressure compensation, self-check, zero calibration and factory-reset controls support instrument setup. Follow the supplied instructions for the selected SO2 sensor configuration.
Specifications
| Item | Specification |
|---|---|
| Model | MH2000-SO2 |
| Detected gas | Sulfur dioxide (SO2) |
| Sensor configurations | Standard or High Performance |
| Standard measuring range options | 0-20, 0-50 or 0-100 ppm |
| High Performance range options | 0-200, 0-500, 0-1000 or 0-2000 ppm |
| Application limit | Neither configuration is suitable for flue-gas environments |
| Sensor principle | Electrochemical |
| Sampling method | Internal sampling pump |
| Pump flow | Up to 1 L/min |
| Pump adjustment | 10 settings |
| Display | LCD dot matrix; gas type, concentration, unit, battery level and time |
| Operating languages | English and Chinese |
| Concentration units | μmol/mol / ppm / mg/m³; 1 μmol/mol = 1 ppm |
| Alarm outputs | Sound, light and vibration |
| Alarm stages | Two |
| Alarm setpoints | User adjustable |
| Sound alarm | 85 dB |
| Alarm lights | Blue for low alarm; red for high alarm |
| Measurement compensation | Temperature and pressure compensation |
| Instrument controls | Self-check, zero calibration and factory reset |
| Battery | 3.6 V, 2300 mAh rechargeable lithium polymer |
| Charging time | 4-6 hours |
| Operating temperature | -20°C to 50°C |
| Operating humidity | 0-95% RH, non-condensing |
| Protection rating | IP65 |
| Dimensions | 205 x 75 x 32 mm |
| Instrument weight | 300 g |
| Data recording / PC export | Optional; excluded from this base configuration |
Recording and Package Choices
Data logging and PC export are optional and excluded from this base configuration. Select the recording option before ordering if stored readings are required. The 300 g instrument uses a rechargeable lithium-polymer battery, with a charging time of 4-6 hours.
Filters, drying accessories and sampling probes are separate package choices. Gallery photographs show the shared pump-detector housing; screen readings are illustrative. A case photograph does not represent two supplied instruments, and a connected cable does not establish included PC export.