Nitrogen Detector with Pump - 0-100% Vol

Mcooh  |  SKU: GAS-N7K4-01
$668.66 USD
Free standard shipping to supported destinations. Taxes calculated at checkout.
Performance Grade

Need help choosing? Tell us what you need to measure.

Shipping & returns

Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.

See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

The MH2000-N2 is a portable nitrogen detector with pump sampling, a 0-100% Vol measurement range and 0.01% Vol reading resolution. Standard and High Performance options provide two sensor configurations for the same nitrogen concentration range. Select the performance option required for your measurement procedure.

Nitrogen Concentration and Configuration Choice

The internal pump draws the gas sample into the instrument. Adjust suction through ten settings, up to a maximum flow of 1 L/min. The displayed nitrogen concentration is expressed as volume percentage; the 0.01% Vol resolution describes the reading increment, rather than measurement accuracy or a trace-impurity detection limit.

Both performance options retain the 0-100% Vol full scale. The performance selection changes the sensor configuration, rather than adding a second gas channel or a different range. Match the named gas, full scale and calibration requirements to your procedure before ordering.

This is the nitrogen configuration. A procedure requiring an oxygen concentration reading requires an instrument specified for oxygen measurement. Select the instrument by the measurement required, and follow its supplied instructions for sampling, calibration and alarm handling.

Display and Alarm Setup

The LCD dot-matrix display shows gas type, concentration, unit, battery status and time. English and Chinese interfaces support instrument setup. Temperature and pressure compensation, self-check, zero calibration and factory reset controls are available.

Set the two alarm stages for your monitoring procedure. Sound, light and vibration provide alarm indications, with an audible alarm rated at 85 dB. The controls allow adjustable alarm points; follow the instrument instructions when checking their operation.

Specifications

Item Specification
Model MH2000-N2
Gas configuration Nitrogen (N2)
Performance options Standard; High Performance
Sensor configuration Electrochemical
Measurement range 0-100% Vol
Reading resolution 0.01% Vol
Sampling method Internal pump
Maximum pump flow 1 L/min
Pump adjustment 10 suction settings
Display LCD dot-matrix display
Displayed information Gas type, concentration, unit, battery status and time
Interface languages English and Chinese
Alarm indications Sound, light and vibration
Alarm stages Two stages with adjustable set points
Audible alarm 85 dB
Measurement compensation Temperature and pressure compensation
Instrument controls Self-check, zero calibration and factory reset
Battery 3.6 V, 2300 mAh rechargeable lithium-polymer
Charging time Approximately 4-6 hours
Operating temperature -20 to 50 Degree C
Operating humidity 0-95% RH, non-condensing
Ingress protection IP65
Housing material Engineering plastic
Dimensions 205 x 75 x 32 mm
Approximate instrument weight 300 g
Data functions Data logging and PC export optional; excluded from High Performance base configuration

Power and Supplied Package

The detector has a 3.6 V, 2300 mAh rechargeable lithium-polymer battery and takes approximately four to six hours to charge. Its IP65 engineering-plastic housing measures 205 x 75 x 32 mm. The instrument weighs approximately 300 g.

The High Performance base package contains one detector, a charging/data cable, an instruction manual and an aluminum carrying case. Data logging and PC export are optional and excluded from this base configuration.

Photos show the shared series housing. Demonstration screen labels and readings may differ from the nitrogen configuration supplied.