Temperature Data Logger TK4800 - 8 or 16 Channels

Testkey  |  SKU: ELE-896F-01
$1,520.34 USD
Free standard shipping to supported destinations. Taxes calculated at checkout.
Model

Need help choosing? Tell us what you need to measure.

Shipping & returns

Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.

See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

The Testkey TK4808 and TK4816 temperature loggers provide 8 and 16 installed thermocouple channels, a 7-inch TFT display and selectable acquisition speeds.

Select 8 or 16 installed thermocouple channels. Acquisition times of 1 s, 500 ms and 250 ms are specified for a full 64-channel configuration.

Model comparison and specifications

Specification TK4808 TK4816
Included measurement channels 8 16
Thermocouple inputs J, K, T, E, S, N, B and R
Thermocouple temperature range −200–1800 °C, depending on thermocouple type
Temperature resolution 0.01 °C
Basic thermocouple measurement accuracy ±0.2% ±5 digits, excluding thermocouple accuracy
Acquisition time for 64 channels Slow 1 s, medium 500 ms, fast 250 ms
Channel isolation 350 V between channels
Cold-junction compensation accuracy 0.5 °C
Supplied temperature probes Thermocouples configured for the ordered model, 2 m each
Platform capacity with optional modules 64 channels, installed channels follow the selected model
Per-channel temperature alarms Independent upper and lower limits, out-of-limit readings change color
Standard interfaces RS232C, USB flash drive interface, TF card interface
Communication protocols SCPI
Input power AC 85–260 V, 50/60 Hz, 10 VA
Specification environment 15–35 °C, <80% RH
Net weight 3 kg
Display 7-inch TFT LCD

Temperature accuracy excludes the thermocouple probe accuracy.

The usable temperature range depends on the connected thermocouple type.

Chassis reference dimensions are 300 × 120 × 320 mm (W × H × D).

Per-channel error correction, open-thermocouple detection, numeric/bar/curve views, and maximum/minimum/average readings are supported.

Additional channel modules are available separately.

Included equipment

  • Selected TK4800 series instrument
  • Thermocouples configured for the ordered model, 2 m per probe
  • USB flash drive
  • Communication cable
  • Data acquisition software

Product photographs show the TK4808 configuration. The selected model determines the supplied electrical specification and channel configuration.