Description

Choose a Testkey TK6900 wide-range DC power supply by its voltage, current and power ratings. The nine configurations provide one output with a 200 W, 360 W or 600 W power limit. Maximum voltage and maximum current are constrained by the selected model’s rated power envelope.

Choose the voltage ceiling and required current, then verify that the test operating point fits the selected model’s 200 W, 360 W or 600 W limit. Compare the accuracy and ripple rows when selecting a supply for precision measurements.

Model comparison and specifications

Specification TK6921A TK6922A TK6932A TK6933A
Maximum output voltage 20 V 30 V 60 V 120 V
Maximum output current 30 A 20 A 10 A 5 A
Maximum output power 200 W
Voltage setting accuracy at 25 ± 5°C ≤0.05%+10mV ≤0.05%+10mV ≤0.03%+5mV ≤0.04%+30mV
Current setting accuracy at 25 ± 5°C ≤0.1%+30mA ≤0.1%+20mA ≤0.1%+10mA ≤0.1%+10mA
Voltage readback accuracy at 25 ± 5°C ≤0.05%+10mV ≤0.05%+10mV ≤0.03%+5mV ≤0.04%+30mV
Current readback accuracy at 25 ± 5°C ≤0.1%+30mA ≤0.1%+20mA ≤0.1%+10mA ≤0.1%+10mA
Load regulation, voltage ≤0.01%+20mV ≤0.01%+25mV ≤0.01%+10mV ≤0.01%+20mV
Load regulation, current ≤0.01%+20mA ≤0.01%+15mA ≤0.05%+4mA ≤0.05%+6mA
Line regulation, voltage ≤0.01%+20mV ≤0.01%+20mV ≤0.01%+10mV ≤0.01%+20mV
Line regulation, current ≤0.01%+20mA ≤0.01%+15mA ≤0.05%+4mA ≤0.05%+6mA
Differential voltage ripple, 20 Hz–2 MHz ≤15 mVpp ≤15 mVpp ≤8 mVpp ≤30 mVpp
Differential current ripple, 20 Hz–2 MHz ≤10 mArms ≤10 mArms ≤6 mArms ≤6 mArms
Voltage rise time, 10–90% ≤100ms ≤100ms ≤150ms ≤200ms
Voltage fall time, 90–10% ≤2s ≤2s ≤2s ≤3.5s
DC voltage meter input limit 20 V 30 V 60 V 120 V
DC voltage meter accuracy 0.05%+10mV 0.05%+10mV 0.03%+5mV 0.04%+30mV
Specification TK6941A TK6942A TK6943A TK6952A TK6953A
Maximum output voltage 30 V 60 V 120 V 60 V 120 V
Maximum output current 30 A 15 A 6 A 25 A 10 A
Maximum output power 360 W 360 W 360 W 600 W 600 W
Voltage setting accuracy at 25 ± 5°C ≤0.05%+10mV ≤0.03%+5mV ≤0.05%+15mV ≤0.03%+5mV ≤0.03%+20mV
Current setting accuracy at 25 ± 5°C ≤0.1%+30mA ≤0.1%+15mA ≤0.1%+20mA ≤0.1%+25mA ≤0.1%+25mA
Voltage readback accuracy at 25 ± 5°C ≤0.05%+10mV ≤0.03%+5mV ≤0.05%+15mV ≤0.03%+5mV ≤0.03%+20mV
Current readback accuracy at 25 ± 5°C ≤0.1%+30mA ≤0.1%+15mA ≤0.1%+20mA ≤0.1%+25mA ≤0.1%+25mA
Load regulation, voltage ≤0.01%+20mV ≤0.01%+30mV ≤0.01%+8mV ≤0.01%+30mV ≤0.01%+25mV
Load regulation, current ≤0.01%+20mA ≤0.05%+6mA ≤0.01%+6mA ≤0.1%+10mA ≤0.5%+10mA
Line regulation, voltage ≤0.01%+20mV ≤0.01%+30mV ≤0.01%+8mV ≤0.01%+30mV ≤0.01%+25mV
Line regulation, current ≤0.01%+20mA ≤0.05%+6mA ≤0.01%+6mA ≤0.1%+10mA ≤0.5%+10mA
Differential voltage ripple, 20 Hz–2 MHz ≤15 mVpp ≤15 mVpp ≤20 mVpp ≤20 mVpp ≤50 mVpp
Differential current ripple, 20 Hz–2 MHz ≤12 mArms ≤8 mArms ≤12 mArms ≤15 mArms ≤15 mArms
Voltage rise time, 10–90% ≤100ms ≤200ms ≤150ms ≤150ms ≤150ms
Voltage fall time, 90–10% ≤2s ≤2s ≤3.5s ≤2s ≤3.5s
DC voltage meter input limit 30 V 60 V 120 V 60 V 120 V
DC voltage meter accuracy 0.05%+10mV 0.03%+5mV 0.05%+15mV 0.03%+5mV 0.03%+20mV

Specifications shared by all listed models

Specification Value
Independent output channels 1
Output operating envelope Voltage, current and power limits apply together
Voltage setting resolution 1 mV below 100 V, 10 mV above 100 V
Voltage readback resolution 1 mV below 100 V, 10 mV above 100 V
Current setting resolution 0.1 mA below 10 A, 1 mA above 10 A
Current readback resolution 0.1 mA below 10 A, 1 mA above 10 A
DC voltage meter resolution 1 mV
Output and compensation connections Front/rear output and sense terminals
Programmable sequences / stored setups 20 trigger files × 1,000 steps, 1,000 stored setups
Overall dimensions, W × H × D 260 × 110 × 445 mm
Communication protocols SCPI, MODBUS
Protection Overvoltage, overcurrent, overtemperature
Communication connections RS232/RS485, USB HOST, USB DEVICE
Net weight 9.65 kg

The integrated eight-channel temperature measurement module is optional and supports K, T, J, N, E, S, R and B thermocouples.

Included equipment

  • Selected TK6900 series instrument
  • TSK107 China-standard (3C), three-core three-pin AC power cord

Product photographs show the TK6952A configuration. The selected model determines the supplied electrical specification and channel configuration.

Browse Power Supply to compare related instruments.