Display Data Polling Module for Hall Flow Sensors with Modbus RS485 and 4 Inputs

mcooh
INS04-FM0123
$198.65
$198.65

Description

The Display Data Polling and Processing Module (Mod X4M) is designed for Hall Flow Sensors, providing seamless data communication and control using the Modbus RS485 protocol. This module supports up to four inputs, ensuring accurate and efficient data handling for industrial applications. Its versatile communication features make it an essential tool for integrating flow sensor data into larger monitoring systems.

Product Features:

  • Modbus Protocol Compliance: Fully compliant with Modbus protocol instructions, supporting command codes 0x03, 0x06, and 0x10 for robust data communication.
  • Versatile Voltage Range: Operates within a wide DC voltage range of 5-24V, suitable for various industrial settings.
  • Configurable Parameters: Includes adjustable baud rate, device address, and flow meter constant K value for customized setup.
  • Real-Time and Cumulative Data: Displays both real-time flow rates and cumulative flow data for comprehensive monitoring.
  • Register Functions: Includes addresses for baud rate, device address, flow constants, and accumulated flow data.
  • Precautions: Device requires a restart for parameter changes to take effect. Ensure pipelines are closed before clearing accumulated flow.

Specifications:

Parameter Details
Operating Voltage Range DC 5-24V
Baud Rate Default 9600 (adjustable)
Modbus Device Address Default 1 (modifiable 1-254)
Flow Meter Constant K Value Default 50 (modifiable)
Inputs 4
Communication Protocol Modbus RS485
Register Functions Various (See detailed instructions)

 

Instructions for use

This product complies with MODBUS protocol instructions
Available command codes 0x03, 0x06, 0x10

Device default parameters:
Baud rate: 9600 (decimal)
MODBUS device address: 1 (decimal)
Flow meter constant K value: 50 (decimal)
This protocol follows the MODBUS protocol instructions
Register address Register function
0x0000 baud rate
0x0001 device address, can be modified to 0x0001-0x00FE (decimal 1-254)
0x0002 Sensor pulse K value, the value read and written is 10 times the actual value
0x0003 Permanent accumulated flow high register, unit, L
0x0004 Permanent cumulative flow low register, unit, L
0x0005 Permanent cumulative flow decimal, the reading is 100 times the actual value, unit, L
0x0006 Permanent cumulative flow pulse value
0x0007 Temporary accumulated flow high register, unit, L
0x0008 Temporary accumulated flow low register, unit, L
0x0009 Temporary cumulative flow decimal, the reading is 100 times the actual value, unit, L
0x000A Temporary cumulative flow pulse value
0x000B Real-time flow, unit: L/min, the reading is 100 times the actual value
0x000C output point 1, control solenoid valve 1, input 0x00FF, turn on, 0x0000, turn off
0x000D output point 2, control solenoid valve 2, input 0x00FF, turn on, 0x0000, turn off
The baud rate defaults to 9600 and the reading is 0. If you modify the baud rate, please modify the parameters as follows. (The parameters that can be modified are 0-3. If the data input is not a value between 0-1, the baud rate is 9600, but it will be displayed as the modified value is not 0 when reading)
Register parameters Baud rate
0 9600
1 4800

Baud rate parameter modification method:

1. The default baud rate is 9600, and the reading is 0.
2. If you modify the baud rate, modify the parameters as follows. (If you enter a value that is not in the table, the baud rate will be restored to 9600, but it will be displayed as the modified value is not 0 when it is read.)
Precautions:
1. After the address, baud rate, K value, and permanent cumulative flow are modified, the device needs to be restarted to take effect.
2. Please close the pipeline before clearing the accumulated flow to prevent water from passing through after the clearing. After 60 seconds, the value will change. If the program changes the value again, the accumulated flow cannot be reset to zero.
3. The temporary accumulated flow will be cleared after power failure, and the permanent accumulated flow will be recorded once every 60S. (The change in flow rate must exceed 1L within 60S to be recorded)

Free Shipping

Under normal circumstances we offer free shipping on all orders, you will see the free shipping option in your cart at checkout. There is no choice of carrier for free shipping, but typically we will ship your order will likely ship using either USPS or FedEx. Full Shipping Policy

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.). Full Returns Policy

When Will My Order Ship?

For Standard Shipping, we aim to pack and ship out your order within 3 business days. During special periods, such as heavy order processing or local inventory shortages that require deployment, please expect it to take an additional day or two for processing.
We ship five days a week, Monday through Friday. Sometimes our mail pickup comes in early afternoon, so tracking for orders shipped later that day may not update until the following business day.
You will receive a shipment confirmation with tracking information via email when your order has shipped. Once you receive this email, we cannot change or cancel your order.

Can I Change The Shipping Address On My Order?

Please contact us immediately via email if you realize that you gave us the wrong shipping address — if it hasn't shipped yet, we might be able to correct it before it goes out the door.
If your order ships to the address provided and is returned to us as undeliverable, then you are responsible for paying the cost of shipping again to resend it to you. If you decide you do not want your order reshipped, we'll refund you for the products less the original shipping charges, once your order returns to our warehouse. We'll reach out to you to coordinate your options before re-shipping.
If your order ships to an incorrect address provided at the time the order is placed and is not retrievable, we are not responsible and cannot offer reimbursement.

Unable to find satisfactory answers ? more FAQs
Display Data Polling Module for Hall Flow Sensors with Modbus RS485 and 4 Inputs
You have successfully subscribed!
This email has been registered