Diffusion Nitrogen Gas Detector - N2 0-100% Vol

Mcooh  |  SKU: GAS-T8N4-01
$515.90 USD
Taxes and shipping calculated at checkout.
Range

In-stock orders usually take 2–4 business days to prepare; delivery typically takes 5–15 business days after dispatch. Availability is confirmed at checkout. Duties and taxes may apply. Shipping details · Return conditions

Need help choosing? Tell us what you need to measure.

Shipping & returns

See our shipping policy for preparation and delivery information, and our return policy for return conditions.

For a delivery estimate to your destination, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

This diffusion nitrogen gas detector measures N2 concentration in surrounding air over a 0-100% Vol range. The MH-1200H-S-N2 uses an electrochemical sensor and presents concentration information on a 128 x 64 monochrome LCD. A rear clip and protective cover support carrying during inspection rounds.

Sampling and Measurement Range

The N2 configuration is supplied with one measurement span: 0-100% Vol, covering nitrogen concentration as a percentage by volume. Diffusion sampling checks air at the instrument's sensor inlet. Keep the inlet exposed to the air being checked and follow the instrument instructions for calibration and pre-use checks. When comparing instruments, select the sampling method needed for your procedure: this configuration uses diffusion sampling.

Display, Alerts and Alarm History

Sound, light and vibration provide three forms of alarm indication. The LCD provides concentration information, while adjustable backlight timing allows the display illumination to be set through the controls. The backlight also turns on automatically during an alarm. The instrument stores 100 alarm records that can be reviewed on its screen, allowing the operator to look back at alarm events without connecting to a computer. Battery voltage and charge-percentage checks and a factory reset function are available through the instrument controls.

Technical Specifications

Model MH-1200H-S-N2
Measured gas Nitrogen (N2)
Sensor principle Electrochemical
Sampling Diffusion
Measurement range 0-100% Vol
Display 128 x 64 monochrome LCD
Alarm modes Sound, light and vibration
Alarm history 100 records viewable on the instrument
Backlight Adjustable timing; automatic illumination during an alarm
Battery 2300 mAh rechargeable lithium
Operating temperature -20 to 50 Degree C
Housing ABS housing with protective cover
Carrying attachment Rear clip
Dimensions 131 x 83 x 35 mm
Approximate instrument weight 240 g including protective cover

Housing and Use Notes

A rechargeable 2300 mAh lithium battery powers the detector. The ABS housing measures 131 x 83 x 35 mm, and the instrument weighs approximately 240 g including its protective cover. Its operating temperature range is -20 to 50 Degree C. Use the instrument within the specified operating conditions and follow your monitoring procedure for setup, checks and alarm handling.

Product photos illustrate the housing shared across this series. Gas labels on the demonstration screen may differ from the selected N2 configuration.