Nitric Oxide Gas Detector with Pump - 20 to 2000 ppm

Mcooh  |  SKU: GAS-N5R9-01
$740.11 USD
Free standard shipping to supported destinations. Taxes calculated at checkout.
Performance Grade
Measuring Range

Need help choosing? Tell us what you need to measure.

Shipping & returns

Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.

See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.

Choosing the right instrument?

Tell us your measurement range, material or target, and operating conditions.

Ask a selection question

Description

The MH2000-NO pump detector measures nitric oxide concentration using an electrochemical sensor. Seven order options cover four Standard ranges and three High Performance ranges. Choose the performance grade and measuring range together for the NO measurement task. One instrument is supplied with the selected sensor configuration and span.

Select the Grade and Measuring Range

Configuration Measuring ranges Application limit
Standard 0-20 / 50 / 100 / 250 ppm Routine NO concentration measurement
High Performance 0-500 / 1000 / 2000 ppm Not suitable for flue-gas environments

The High Performance options on this page cannot be used in flue-gas environments. Select the separate flue-gas-specific NO configuration when that application is required. Each measuring span belongs to an individual order option; the supplied instrument does not automatically switch between all seven versions. The grade name identifies the sensor configuration and does not establish a numerical accuracy value.

Portable Sampling and Alarm Controls

The internal pump delivers up to 1 L/min with ten adjustment settings. An LCD dot-matrix display shows the gas type, concentration, unit, battery level and time. English and Chinese interfaces are available. Concentration units include μmol/mol, ppm and mg/m³, with 1 μmol/mol equivalent to 1 ppm.

Two alarm stages have adjustable setpoints. Sound, light and vibration provide the alarm outputs, including an 85 dB sound alarm and blue/red alarm lights. Temperature and pressure compensation, self-check, zero calibration and factory reset are provided for instrument setup. Use the controls according to the supplied instructions for the selected NO sensor.

Specifications

Item Specification
Model MH2000-NO
Detected gas Nitric oxide (NO)
Sensor principle Electrochemical
Sensor configurations Standard or High Performance
Standard range options 0-20, 0-50, 0-100 and 0-250 ppm
High Performance range options 0-500, 0-1000 and 0-2000 ppm
High Performance application limit Not suitable for flue-gas environments
Sampling method Internal sampling pump
Pump flow Up to 1 L/min
Pump adjustment 10 settings
Display LCD dot matrix; gas type, concentration, unit, battery level and time
Operating languages English and Chinese
Concentration units μmol/mol / ppm / mg/m³; 1 μmol/mol = 1 ppm
Alarm outputs Sound, light and vibration
Alarm stages Two
Alarm setpoints User adjustable
Sound alarm 85 dB
Alarm lights Blue for low alarm; red for high alarm
Measurement compensation Temperature and pressure compensation
Instrument controls Self-check, zero calibration and factory reset
Battery 3.6 V, 2300 mAh rechargeable lithium polymer
Charging time 4-6 hours
Operating temperature -20°C to 50°C
Operating humidity 0-95% RH, non-condensing
Protection rating IP65
Dimensions 205 x 75 x 32 mm
Instrument weight 300 g
Data recording / PC export Optional; excluded from this base configuration