LCR Meter TK2810 with Four Fixed Test Frequencies
LCR Meter TK2810 with Four Fixed Test Frequencies - TK2810 Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.
See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.
LCR Meter TK2810 with Four Fixed Test Frequencies - TK2810 Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
The Testkey TK2810 LCR meter provides four fixed test frequencies at 100 Hz, 120 Hz, 1 kHz and 10 kHz. Choose the frequency and measurement parameter appropriate to the component being evaluated, using the instrument specifications to define the test conditions.
The measurement functions cover inductance, capacitance and resistance-related component evaluation. The technical table identifies the supported parameters, signal settings, display and accuracy. Basic accuracy applies under the corresponding measurement conditions.
Measurement and control
Comparator and interface functions support repeated component checks and result handling. Review the supplied test fixture and connection arrangement when planning a recurring measurement setup. The standard package below identifies the accessories supplied with this configuration.
Technical specifications
| Specification | Value |
|---|---|
| Display | 4.3-inch 480 x 272 24-bit color TFT |
| Source output impedance | 30 Ω / 100 Ω |
| Impedance, resistance and reactance display range | 0.00001 Ω–99.9999 MΩ |
| Capacitance display range | 0.00001 pF–9.99999 F |
| Inductance display range | 0.00001 µH–99.9999 kH |
| Dissipation factor display range | 0.00001–9.99999 |
| Quality factor display range | 0.00001–99999.9 |
| Percentage deviation display range | −999.999% to 999.999% |
| Correction | Open, short and load calibration |
| List scan | 10 points |
| Equivalent circuit | Series and parallel |
| Range selection | Automatic and hold |
| Trigger modes | Internal, manual, external, bus |
| Calculation | Direct reading, ΔABS, Δ% |
| Comparator | 10-bin sorting, BIN1–BIN9, NG, AUX, bin counts, PASS, FAIL |
| Test frequencies | 100 Hz, 120 Hz, 1 kHz, 10 kHz |
| Basic accuracy | 0.1 % |
| Measurement time | FAST approximately 19, MED 83, SLOW 333 ms |
| AC signal levels | 0.01, 0.02, 0.05, 0.1, 0.25, 0.5, 1 V RMS |
| Measured parameters | L, C, R, |Z|, D, Q, phase in degrees/radians, Vm, Im, Δ% |
| Memory | 40 internal setup files, USB setup and CSV data files |
| Standard interfaces | USB HOST, USB DEVICE, RS232C, HANDLER |
| Communication protocols | SCPI and MODBUS |
| Phase display range (degrees) | −179.999° to +179.999° |
| Phase display range (radians) | −3.14159 to +3.14159 rad |
| Overall dimensions (W x H x D) | 258 x 110 x 300 mm (W x H x D) |
| Net weight | 2.35 kg |
Chassis reference dimensions are 213 x 87 x 270 mm (W x H x D).
Standard package
- Selected TK2810 instrument
- TSK107 Three-core mains power cord
- TSK202 Kelvin test clip
Manufacturer photographs show the TK2810 panel. The offered configuration uses the four fixed test frequencies listed in the specifications.
Browse LCR Meters to compare related instruments.