Ultrasonic Wall Thickness Gauge - LS213, 0.8-350 mm
Ultrasonic Wall Thickness Gauge - LS213, 0.8-350 mm Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.
See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
The Linshang LS213 ultrasonic wall thickness gauge measures materials that transmit ultrasound, including suitable metals, glass, ceramics and plastics. The standard 5 MHz dual-element probe covers 0.8–350 mm on 45# steel, with 0.01 mm resolution up to 100 mm and 0.1 mm resolution above that band.
Wall thickness checks with a standard probe
Use the LS213 with the standard probe for accessible pipe and plate locations that meet the probe’s measuring-area and geometry limits. The minimum pipe dimensions in the specification are for 45# steel; they are not universal limits for every material.
Set the appropriate sound velocity before testing. A known-thickness sample of the same material can be used to establish the velocity instead of relying on a generic preset. Apply couplant and hold the probe still with its full contact face supported. The opposite surface must be parallel or coaxial with the measuring surface.

LS213 range, display and reference values
| Standard probe | 5 MHz, 10 mm dual-element probe |
|---|---|
| Standard-probe range on 45# steel | 0.8–350 mm |
| Display resolution | 0.8–100 mm: 0.01 mm; 100–350 mm: 0.1 mm |
| Accuracy in standard mode; H is reference thickness | H < 10 mm: ±0.05 mm; H ≥ 10 mm: ±0.5%H |
| Minimum measuring area, standard probe | 10 mm diameter |
| Standard-probe pipe limit on 45# steel | 20 mm outside diameter x 3 mm wall |
| Sound velocity setting | 1000–19999 m/s |
| Display and units | 240 x 160 dot-matrix LCD; mm / inch |
| Power | Two 1.5 V AA alkaline batteries |
| Host dimensions | 142 x 72 x 28 mm |
| Instrument weight | Approx. 230 g |

Coatings and alternative probes
With the standard probe, E-E mode uses successive back-wall echoes to measure the substrate beneath a coating. Its stated limits are 0.2–2.5 mm coating thickness and 4–60 mm substrate thickness on 45# steel. Enable E-E mode for that application; the full normal measuring range does not apply in this mode. It reports substrate thickness rather than a separate coating thickness.
The LS213 also supports micro-diameter, coarse-crystal and high-temperature probes. The 7 MHz PT-06 covers 0.75–80 mm on 45# steel, while 2 MHz ZT-12 and 5 MHz GT-12 cover 3–200 mm. Choose the probe to match the material, access and measuring conditions; these probes do not share the standard probe’s full range.
Record results and compare locations
Bluetooth connects the gauge to the UT and HL app for Android 7.0 or later. Dedicated PC software supports measurement data handling and export. The instrument can store up to 999 readings; statistics mode shows maximum, minimum and average values, while QC mode compares readings with user-set limits.
Automatic gain adapts signal amplification to the workpiece. Use the built-in reference block for calibration, and keep the probe and block clean. The displayed increment is not the same as measurement accuracy; probe type, material velocity and coupling all matter when interpreting readings.