Thin UV Energy Meter LS136 for Mercury Lamp Curing
Thin UV Energy Meter LS136 for Mercury Lamp Curing In stock. Shipping calculated at checkout.
In-stock orders usually take 2–4 business days to prepare; delivery typically takes 5–15 business days after dispatch. Availability is confirmed at checkout. Duties and taxes may apply. Shipping details · Return conditions
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
See our shipping policy for preparation and delivery information, and our return policy for return conditions.
For a delivery estimate to your destination, contact Mcooh.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
The Linshang LS136 thin UV energy meter measures irradiance, accumulated energy and temperature from high-pressure mercury and halogen lamps. Its 315–400 nm response peaks at 365 nm, and the 7.6 mm-thick metal body fits curing-machine measuring positions with limited clearance.

Review energy and peak values after the run
During measurement, the OLED shows accumulated energy, real-time irradiance, temperature and elapsed time. The stopped result provides energy together with maximum irradiance and maximum temperature. The latest completed test is retained after power-off and appears at the next startup.
Manual mode starts and stops from the meter controls. Automatic mode waits for the selected trigger irradiance and records during exposure until the signal falls below the threshold or the 32-minute period is reached. Choose the mode to match the curing process before placing the meter.
LS136 spectral and physical data
| Spectral response | 315–400 nm; peak 365 nm |
|---|---|
| Irradiance range | 0–2000 mW/cm² |
| Irradiance resolution | 0.1 mW/cm² |
| Irradiance accuracy, H = reference value | H < 5 mW/cm²: ±0.5 mW/cm²; H ≥ 5 mW/cm²: ±10%H |
| Energy range | 0–999999 mJ/cm² |
| Sampling speed | 2048 samples/second |
| Recording period | 32 minutes |
| Temperature measurement | -55°C to +125°C |
| Power supply | Rechargeable lithium battery, 3.7 V / 400 mAh |
| Display | 128 x 64 dot-matrix OLED |
| Dimensions | 102 mm diameter x 7.6 mm thick |
| Weight | 136 g |

Recharge and prepare the measuring position
The built-in lithium battery charges through USB from a suitable 5 V supply. Face the sensor toward the UV source and keep the detector clean. The removable heat shield protects the display from close-range, high-power UV irradiation.
The 7.6 mm body dimension describes the instrument itself. Allow suitable clearance for the measuring arrangement and protective cover. The temperature channel reports process temperature over its listed measuring range.
Keep the test settings with each result
Use consistent placement and select the smoothing setting that matches the light-source power frequency. Record the lamp type, trigger mode, exposure time and instrument settings with the energy result. Store the meter in a dry environment to protect the sensor between measurements.