Film Transmission Meter LS160A with 1400 nm IR Rejection
Film Transmission Meter LS160A with 1400 nm IR Rejection Free standard shipping to supported destinations. See the shipping policy for preparation and transit estimates.
Need help choosing? Tell us what you need to measure.
Shipping & returns
Shipping & returns
Free standard shipping is available to supported destinations. Delivery time includes order preparation and transit and varies by destination. See our shipping policy for current delivery estimates and availability.
See our return policy for return conditions. For an order-specific delivery question, contact Mcooh.
Choosing the right instrument?
Tell us your measurement range, material or target, and operating conditions.
Description
Description
The Linshang LS160A film transmission meter measures visible-light transmission, ultraviolet rejection and infrared rejection with a 1400 nm infrared source. Its narrow slot accepts transparent film samples less than 0.8 mm thick for solar-film selection, demonstrations and repeat comparisons.

A 1400 nm infrared check for film comparison
Choose the LS160A when a 1400 nm infrared reading is the required comparison point, including evaluations of reflective and metallic film samples. The meter also uses a 365 nm UV source and a 530 nm visible-light channel, displaying the three results together.
Compare samples with the same instrument and measurement conditions. Film response varies with wavelength, so record the 1400 nm infrared channel alongside the result when sharing a comparison. Check sample thickness before inserting the material into the opening.

Read and retain the measurement
Power on with the test slot empty and allow self-calibration to finish. Insert the film once the empty-slot display reads 100% VLT and 0% UVR/IRR. The result appears on the backlit LCD, with all three values available for review.
The ON/Hold button retains a measurement after removing the film, which helps when the measuring position is awkward to read. Release hold before checking another sample. Four AAA alkaline batteries power the instrument, and it switches off automatically after three minutes without a button press.
LS160A optical and size specifications
| Model | LS160A |
|---|---|
| IR peak wavelength | 1400 nm |
| Visible-light peak wavelength | 530 nm |
| Maximum sample thickness | Less than 0.8 mm |
| UV peak wavelength | 365 nm |
| Resolution | 0.1% |
| Accuracy | ±2% for colorless, transparent materials |
| Power supply | 4 AAA alkaline batteries |
| Dimensions | 93 x 52 x 25 mm |
Match the tester to the sample
The 0.8 mm opening is intended for thin film samples. Glass and film-on-glass checks require a meter with a suitable larger opening. Keep the slot unobstructed at startup and use a clean, consistently positioned sample.
The ±2% accuracy specification applies to colorless, transparent materials. Colored or optically coated samples can have lower accuracy. Use the selected channel and actual sample conditions when interpreting or comparing results.
Manufacturer documentation
Linshang LS160/LS160A user manual (PDF, English) (V6.04, 2024-08-07). Use the instructions for the LS160A model.